CoChat

Comparative Device Assessments

Ignaut, Debra A., Schwartz, Sherwyn L., Sarwat, Samiha, Murphy, Heather L. · 2009 · The Diabetes Educator
Cited by 62

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Purpose The purpose of this study was to compare pen device-naïve patients’ preferences for Humalog® KwikPen™ (insulin lispro injection) (Eli Lilly and Company, Indianapolis, IN) to use of a vial and syringe and FlexPen® (insulin aspart injection) (Novo Nordisk A/S, Bagsvaerd, Denmark). Methods This open-label, randomized, crossover 1-day study tested the hypotheses that KwikPen was preferred to vial and syringe, and if this was found to be a significant preference, that KwikPen was preferred to FlexPen. Accuracy of doses prepared, ease of use via insulin device assessment battery, and preference via insulin device preference battery were administered following each pen evaluation, and a final preference question administered following the evaluation of both pens. Clinical measures were not included as subjects injected into an appliance to simulate the injection experience. Primary outcome variables were evaluated by Question 13 of the insulin device preference battery and the final preference question. Results Among 232 enrolled patients randomized to 1 of 4 sequences (n = 58), Humalog KwikPen was significantly preferred over vial and syringe and over FlexPen. After patients were asked to assess Humalog KwikPen or FlexPen versus V&S by choosing “strongly agreed” or “agreed” to the following attributes: easy to use, easy to hold in their hands when injecting, and easy to press the injection button, the results exhibited significant differences in patient responses. Humalog KwikPen was significantly more accurate and was preferred to vial and syringe in appearance, quality, discretion, convenience, public use, easy to learn, easy to use, reliability, dose confidence, following insulin regimen, overall satisfaction, and recommendation to others. Conclusions Humalog KwikPen was significantly preferred over vial and syringe and FlexPen. When compared with vial and syringe, Humalog KwikPen and FlexPen were easier to use and operate, demonstrated superior accuracy of doses prepared, and preferred by pen-naïve users.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0145721709340056

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 62

Metadata

Authors
Ignaut, D. A., Schwartz, S. L., Sarwat, S., & Murphy, H. L.
Venue
The Diabetes Educator
Published
2009-09
Volume
35
Issue
5
Pages
789-798
ISSN
  • 0145-7217 (ISSN-L)
  • 1554-6063
OpenAlex
W2164894301
Cited by
62
References
2
FWCI
5.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparative Device Assessments. https://app.cochat.ai/papers/10.1177/0145721709340056
The paper
Ignaut, D. A., Schwartz, S. L., Sarwat, S., & Murphy, H. L. (2009). Comparative Device Assessments. The Diabetes Educator. https://doi.org/10.1177/0145721709340056

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.