Clinical use of the respiratory quotient obtained from indirect calorimetry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The respiratory quotient (RQ) obtained from indirect calorimetry (IC), defined by the ratio carbon dioxide production (VCO2)/oxygen consumption (VO2), is affected by extremes of substrate use by the body. Underfeeding, which promotes use of endogenous fat stores, should cause decreases in the RQ, whereas overfeeding, which results in lipogenesis, should cause increases in the RQ. Marked increases in VCO2 (with subsequent increases in RQ) in response to overfeeding may cause respiratory compromise in patients with limited pulmonary reserve. Thus, variation in the RQ in response to the feeding regimen may indicate inappropriate feeding and serve as a marker for patient intolerance. This prospective, multicenter study was designed to determine the clinical use of RQ for monitoring adequacy and tolerance of nutrition support. METHODS: Patients in any 1 of 30 long‐term acute care Kindred hospitals made nil orally (NPO) and placed on total parenteral or enteral feeding were eligible for this study. Arterial blood gas, serum ketones, 24‐hour collection of urine urea nitrogen, and IC measurements were obtained on all. Actual volume of enteral/parenteral feeding infused over the 24 hours before performance of IC was documented. RESULTS: A total of 263 patients (mean age, 70.2 years, 57.4% male) were entered in the study. Of the 263 study patients, 88.6% required mechanical ventilation, and 92.0% received enteral tube feeding only. Overall, 41.5% of patients were overfed, receiving >110% of required calories, whereas 34.2% were underfed, receiving <90% of required calories. The ratio of calories provided/required correlated significantly with overall measured RQ (p <.0001; R2 =.16). Correcting for the metabolism of protein by calculating a nonprotein RQ (NPRQ) from a 24‐hour urine urea nitrogen did not improve this correlation (p <.0001, R2 =.32). Using a measured NPRQ >1.0 to identify overfeeding had an acceptable specificity of 85.1% but a low sensitivity of 38.5%. Similarly, use of a NPRQ <0.85 to determine underfeeding had a specificity of 72.2% and a sensitivity of 55.8%. Comparing the measured NPRQ with a predicted reference RQ (based on percent infusion of carbohydrate/fat and the Lusk table) did not improve the overall use of RQ. In the majority of patients (67.7%), comparison of the measured NPRQ to the predicted value failed to differentiate appropriate (meeting 100% +/‐ 10% of requirements) from inappropriate feeding. Deviation of the measured NPRQ from predicted failed to identify factors unrelated to substrate use purported to affect the RQ (such as acid/base disturbances or hyper/hypoventilation). Increasing measured RQ did correlate significantly with increasing respiratory rate (p =.002, R2 =.04) and decreasing tidal volume (p =.002, R2 =.04), suggesting reduced tolerance with development of shallow rapid respirations and ventilatory compromise. CONCLUSIONS: Although changes in the overall and nonprotein RQ correlate to percent calories provided/required, low sensitivity and specificity limit its efficacy as an indicator of over‐ or underfeeding. The RQ should not be used to finely adjust the nutrition support regimen. Elevation of overall measured RQ > or = 1.0 may be associated with reduced tolerance and mild respiratory compromise. The clinical use of RQ is limited to a marker of test validity (to confirm measured RQ values are in physiologic range) and a marker for respiratory tolerance of the nutrition support regimen.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jéquier, E., & Felber, J.-P. (1987) · Baillière's Clinical Endocrinology and Metabolism · doi:10.1016/s0950-351x(87)80011-3 · Cited by 191
Cited by
Microbial lipases and their industrial applications: a comprehensive review
Chandra, P., Enespa, Singh, R., & Arora, P. K. (2020) · Microbial Cell Factories · doi:10.1186/s12934-020-01428-8 · Cited by 887
Stapel, S. N., de Grooth, H.-J. S., Alimohamad, H., Elbers, P. W. G., Girbes, A. R. J., Weijs, P. J. M., & Oudemans-van Straaten, H. M. (2015) · Critical Care · doi:10.1186/s13054-015-1087-2 · Cited by 118
“This will temporarily modulate VCO2 [34]; however, over 24 h, mean VCO2 reflects CO2 produced by metabolism.”
BackgroundFarmer, B. C., Williams, H. C., Devanney, N. A., Piron, M. A., Nation, G. K., Carter, D. J., Walsh, A. E., Khanal, R., Young, L. E. A., Kluemper, J. C., et al. (2021) · Molecular Neurodegeneration · doi:10.1186/s13024-021-00483-y · Cited by 87
“While using indirect calorimetry for metabolic studies is common in clinical settings and exercise studies [75, 76], to our knowledge the method has not been previously applied to investigate biomarkers of cognitive impairment.”
MethodCan calculation of energy expenditure based on CO2 measurements replace indirect calorimetry?
Oshima, T., Graf, S., Heidegger, C.-P., Genton, L., Pugin, J., & Pichard, C. (2017) · Critical Care · doi:10.1186/s13054-016-1595-8 · Cited by 48
“disturbance [5], suggesting the difficulty of predicting the RQ.”
BackgroundMethodInfluentialSato, T., Sayama, N., Inoue, M., Morita, A., & Miura, S. (2020) · Bioscience, Biotechnology, and Biochemistry · doi:10.1080/09168451.2020.1792268 · Cited by 4
Metadata
- Authors
- McClave, S., Lowen, C., Kleber, M., McConnell, J., Jung, L., & Goldsmith, L.
- Venue
- Journal of Parenteral and Enteral Nutrition
- Publisher
- Wiley
- Published
- 2003-01
- Volume
- 27
- Issue
- 1
- Pages
- 21-26
- ISSN
- 0148-6071 (ISSN-L)
- 1941-2444
- OpenAlex
- W2056723264
- Cited by
- 239
- References
- 1
- FWCI
- 6.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical use of the respiratory quotient obtained from indirect calorimetry. https://app.cochat.ai/papers/10.1177/014860710302700121
- The paper
- McClave, S., Lowen, C., Kleber, M., McConnell, J., Jung, L., & Goldsmith, L. (2003). Clinical use of the respiratory quotient obtained from indirect calorimetry. Journal of Parenteral and Enteral Nutrition. https://doi.org/10.1177/014860710302700121
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.