The DOI matches its Crossref record.
Hub Colonization as the Initial Step in an Outbreak of Catheter‐Related Sepsis Due to Coagulase Negative Staphylococci during Parenteral Nutrition
Abstract
A prospective study was carried out to determine the pathogenesis of coagulase negative staphylococci catheter‐related sepsis during parenteral nutrition. Forty‐three catheters were cultured by semiquantitative and quantitative methods. The skin around the puncture site was cultured at the time of catheter removal and three segments of the catheter were cultured apart: the hub, the proximal subcutaneous segment, and the tip. Skin cultures were negative (89%) or yielded different coagulase negative staphylococci from those recovered in catheter and/or blood. Seventeen catheters were the source of sepsis. In 15 cases an infected hub was associated with an infected tip. In two cases the hub was negative (one sepsis due to mixture contamination and the other due to hematogenous seeding of the catheter tip). Sixteen cases of sepsis were due to coagulase negative staphylococci. Staphylococcus epidermidis has been the species most commonly isolated, followed by Staphylococcus haemolyticus, Staphylococcus saprophyticus, and Staphylococcus hominis. In our patients most catheter sepsis have their origin in an infected hub and are not due to migration of skin bacteria along catheter subcutaneous tunnel. (Journal of Parenternal and Enteral Nutrition 8:668–672, 1984)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Maki, D. G., Kluger, D. M., & Crnich, C. J. (2006) · Mayo Clinic Proceedings · doi:10.4065/81.9.1159 · Cited by 1,549
Intravascular-catheter-related infections
Raad, I. (1998) · The Lancet · doi:10.1016/s0140-6736(97)10006-x · Cited by 627
Raad, I., Costerton, W., Sabharwal, U., Sadlowski, M., Anaissie, E., & Bodey, G. P. (1993) · Journal of Infectious Diseases · doi:10.1093/infdis/168.2.400 · Cited by 553
Liñares, J., Sitges-Serra, A., Garau, J., Pérez, J. L., & Martín, R. (1985) · Journal of Clinical Microbiology · doi:10.1128/jcm.21.3.357-360.1985 · Cited by 474
Self-citationHeard, S. O., Wagle, M., Vijayakumar, E., McLean, S., Brueggemann, A., Napolitano, L. M., Edwards, L. P., O'Connell, F. M., Puyana, J. C., & Doern, G. V. (1998) · Archives of Internal Medicine · doi:10.1001/archinte.158.1.81 · Cited by 473
Metadata
- Authors
- Sitges‐Serra, A., Puig, P., Liñares, J., Pérez, J. L., Farreró, N., Jaurrieta, E., & Garau, J.
- Venue
- Journal of Parenteral and Enteral Nutrition
- Publisher
- Wiley
- Published
- 1984-11
- Volume
- 8
- Issue
- 6
- Pages
- 668-672
- ISSN
- 0148-6071 (ISSN-L)
- 1941-2444
- OpenAlex
- W1993445401
- Cited by
- 218
- References
- 0
- FWCI
- 16.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hub Colonization as the Initial Step in an Outbreak of Catheter‐Related Sepsis Due to Coagulase Negative Staphylococci during Parenteral Nutrition. https://app.cochat.ai/papers/10.1177/0148607184008006668
- The paper
- Sitges‐Serra, A., Puig, P., Liñares, J., Pérez, J. L., Farreró, N., Jaurrieta, E., & Garau, J. (1984). Hub Colonization as the Initial Step in an Outbreak of Catheter‐Related Sepsis Due to Coagulase Negative Staphylococci during Parenteral Nutrition. Journal of Parenteral and Enteral Nutrition. https://doi.org/10.1177/0148607184008006668
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.