Aspirating Gastric Residuals Causes Occlusion of Small‐Bore Feeding Tubes
The DOI matches its Crossref record.
Abstract
A frequent mechanical problem encountered with small‐bore feeding tubes is lumenal obstruction of the tube. A number of studies have described methods to prevent tube occlusion and restore patency once the tube becomes occluded. It has been observed that most intact protein formulas will clot when acidified to a pH of less than 5.0. This study evaluated the question of whether gastric feeding tubes occlude more frequently when they are used for checking gastric residuals by aspirating acidic gastric juices into the tube than when gastric residuals are not checked. Patients who were fed intragastrically via a small‐bore feeding tube with intact protein formulas were divided into two groups. Gastric residuals were checked in group A patients every 4 hours, whereas no residuals were checked in group B patients. Fifteen patients in group A were followed for a total of 138 patient days and 13 patients in group B were followed for 154 patient days. Ten occlusive episodes occurred in the group A patients, whereas only one occlusive episode occurred in the group B patients. This difference was statistically significant (p =.0171). We concluded that small‐bore feeding tubes occlude more frequently when used to aspirate gastric residuals. (Journal of Parenteral and Enteral Nutrition 17:243–246, 1993)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
McClave, S. A., Taylor, B. E., Martindale, R. G., Warren, M. M., Johnson, D. R., Braunschweig, C., McCarthy, M. S., Davanos, E., Rice, T. W., Cresci, G. A., et al. (2016) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607115621863 · Cited by 3,982
“Use of GRVs leads to increased enteral access device clogging, inappropriate cessation of EN, consumption of nursing time, and allocation of healthcare resources and may adversely affect outcome through reduced volume of EN delivered.(110) Three studies have shown that eliminating the practice of using GRVs improves d…”
BackgroundTaylor, B. E., McClave, S. A., Martindale, R. G., Warren, M. M., Johnson, D. R., Braunschweig, C., McCarthy, M. S., Davanos, E., Rice, T. W., Cresci, G. A., et al. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000001525 · Cited by 1,476
“Use of GRVs leads to increased enteral access device clogging, inappropriate cessation of EN, consumption of nursing time, and allocation of healthcare resources and may adversely affect outcome through reduced volume of EN delivered.(110) Three studies have shown that eliminating the practice of using GRVs improves d…”
BackgroundASPEN Safe Practices for Enteral Nutrition Therapy
Boullata, J. I., Carrera, A. L., Harvey, L., Escuro, A. A., Hudson, L., Mays, A., McGinnis, C., Wessel, J. J., Bajpai, S., Beebe, M. L., et al. (2017) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607116673053 · Cited by 511
Gastroenteric tube feeding: Techniques, problems and solutions
Blumenstein, I. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i26.8505 · Cited by 455
Metadata
- Authors
- Powell, K. S., Marcuard, S. P., Farrior, E. S., & Gallagher, M. L.
- Venue
- Journal of Parenteral and Enteral Nutrition
- Publisher
- Wiley
- Published
- 1993-05
- Volume
- 17
- Issue
- 3
- Pages
- 243-246
- ISSN
- 0148-6071 (ISSN-L)
- 1941-2444
- OpenAlex
- W2073745177
- Cited by
- 89
- References
- 0
- FWCI
- 2.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Aspirating Gastric Residuals Causes Occlusion of Small‐Bore Feeding Tubes. https://app.cochat.ai/papers/10.1177/0148607193017003243
- The paper
- Powell, K. S., Marcuard, S. P., Farrior, E. S., & Gallagher, M. L. (1993). Aspirating Gastric Residuals Causes Occlusion of Small‐Bore Feeding Tubes. Journal of Parenteral and Enteral Nutrition. https://doi.org/10.1177/0148607193017003243
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.