Cited by 52Clinical Reasoning and Diagnostic SkillsHemodynamic Monitoring and TherapyHeart Failure Treatment and Management

Hemodynamic assessment in managing the critically iii: is physician confidence warranted?

Dawson, Neal V., Connors, Alfred F., Speroff, Theodore, Kemka, Ashish, Shaw, Patricia, Arkes, Hal R.·1993·Medical Decision Making

Abstract

Prior to right-heart catheterization of 846 patients, 198 study physicians estimated values of pulmonary capillary wedge pressure (WP), cardiac index (CI), and systemic vascular resis tance index (VRI). The physicians also expressed their confidence in these estimates. Actual values of WP, CI, and VRI as determined by catheterization enabled the authors to evaluate the quality of the physicians' judgments. The discrimination of the judgments was modest; areas under the ROC curves for WP, CI, and VRI were 0.724, 0.681, and 0.656, respectively. Calculated using clinically relevant cutoff values, sensitivities were 64%, 50%, and 64%, and specificities were 71%, 75%, and 63%, respectively. Calibration of the estimates of WP, CI, and VRI was also modest; physicians tended to overestimate low values and underestimate high values. Physicians were generally confident of their estimates, but there was no relation between confidence and accuracy. Experienced physicians were no more accurate than less experienced ones, although they were significantly more confident. The authors conclude that physicians should not use their levels of confidence in their subjective estimates of cardiac function in deciding whether to base therapy on these estimates. Key words: con fidence; accuracy; discrimination; hemodynamic status; cardiac function; physicians. (Med Decis Making 1993;13:258-266)

Integrity signals

Registry

Crossref · 10.1177/0272989x9301300314

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Humans often underestimate susceptibility to errors and tend to be overconfident, reporting higher accuracy estimates than they actually achieve.

    “Unfortunately, humans often underestimate the susceptibility to errors in certain tasks and tend to be overconfident, reporting higher accuracy estimates than they actually achieve.”

    From Enhancing human-AI collaboration: The case of colonoscopy (2024) · cites this paper as [37]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Dawson, N. V., Connors, A. F., Speroff, T., Kemka, A., Shaw, P., & Arkes, H. R.
Affiliations
  • MetroHealth (US)
  • MetroHealth Medical Center (US)
Venue
Medical Decision Making
Published
1993-08
Volume
13
Issue
3
Pages
258-266
ISSN
  • 0272-989X (ISSN-L)
  • 1552-681X
OpenAlex
W2083419545
Cited by
52
References
1
Citations by year
2024: 1 · 2023: 3 · 2022: 1 · 2021: 2 · 2020: 1 · 2019: 3 · 2018: 1 · 2017: 2 · 2016: 3 · 2015: 7 · 2014: 4 · 2013: 2
FWCI
1.03
Type
journal article
Language
en
Open access
closed
Locations
  • Medical Decision Making (publishedVersion)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
Topics
  • Health Sciences › Medicine › Family Practice › Clinical Reasoning and Diagnostic Skills
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Failure Treatment and Management
Keywords
hemodynamic assessment, critically ill patients, right heart catheterization, pulmonary capillary wedge pressure, cardiac index, systemic vascular resistance index, physician judgment, diagnostic accuracy, physician experience
MeSH terms
Diagnostic Errors, False Negative Reactions, False Positive Reactions, Female, Cardiac Catheterization, Hemodynamics, Humans, Male, Middle Aged, Physicians, Prospective Studies, ROC Curve, Sensitivity and Specificity, Reproducibility of Results, Chi-Square Distribution, Critical Illness

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review