Estimating Diagnostic Accuracy from Multiple Conflicting Reports: A New Meta-analytic Method
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Reports of diagnostic accuracy often differ. The authors present a method to summarize disparate reports that uses a logistic transformation and linear regression to produce a summary receiver operating characteristic curve. The curve is useful for summarizing a body of diagnostic accuracy literature, comparing technologies, detecting outliers, and finding the optimum operating point of the test. Examples from clinical chemistry and diagnostic radiology are provided. By extending the logic of meta-analysis to diagnostic testing, the method provides a new tool for technology assessment. Key words: meta-analysis; sensitivity and specificity; decision support; data interpretation, statistical; regression analysis; diagnostic accuracy. (Med Decis Making 1993;13:313-321)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Summing Up: The Science of Reviewing Research
Light, R. J., & Pillemer, D. B. (1984) · Harvard University Press eBooks · doi:10.4159/9780674040243 · Cited by 1,427
Moses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405
Self-citation(1982) · Cited by 1,288
Meta-Analysis in Clinical Research
L'ABBÉ, K. A., DETSKY, A. S., & O'ROURKE, K. (1987) · Annals of Internal Medicine · doi:10.7326/0003-4819-107-2-224 · Cited by 1,267
The Robustness of the "Binormal" Assumptions Used in Fitting ROC Curves
Hanley, J. A. (1988) · Medical Decision Making · doi:10.1177/0272989x8800800308 · Cited by 309
The Diagnostic Accuracy of Rapid Dipstick Tests to Predict Urinary Tract Infection
Hurlbut, T. A., & Littenberg, B. (1991) · American Journal of Clinical Pathology · doi:10.1093/ajcp/96.5.582 · Cited by 179
Self-citationMaximum Likelihood Estimation of Parameters of Signal Detection Theory–A Direct Solution
Dorfman, D. D., & Alf, E. (1968) · Psychometrika · doi:10.1007/bf02289677 · Cited by 177
Focusing Technology Assessment Using Medical Decision Theory
Phelps, C. E., & Mushlin, A. I. (1988) · Medical Decision Making · doi:10.1177/0272989x8800800409 · Cited by 168
Kardaun, J. W. P. F., & Kardaun, O. J. W. F. (1990) · Methods of Information in Medicine · doi:10.1055/s-0038-1634759 · Cited by 74
Technetium bone scanning in the diagnosis of osteomyelitis
Littenberg, B., & Mushlin, A. I. (1992) · Journal of General Internal Medicine · doi:10.1007/bf02598005 · Cited by 37
Self-citationSensitivities and Specificities of Diagnostic Tests
Swets, J. A. (1982) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1982.03330050032020 · Cited by 34
Cited by
Reitsma, J. B., Glas, A. S., Rutjes, A. W. S., Scholten, R. J. P. M., Bossuyt, P. M., & Zwinderman, A. H. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.02.022 · Cited by 3,369
“More details can be found elsewhere [9,12,14–18].”
The diagnostic odds ratio: a single indicator of test performance
Glas, A. S., Lijmer, J. G., Prins, M. H., Bonsel, G. J., & Bossuyt, P. M. M. (2003) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(03)00177-x · Cited by 2,261
“Simple pooling of sensitivity and specificity usually is inappropriate, as this approach ignores threshold differences [11,18].”
BackgroundMethodInfluentialEmpirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Performance of Transient Elastography for the Staging of Liver Fibrosis: A Meta-Analysis
Friedrich–Rust, M., Ong, M., Martens, S., Sarrazin, C., Bojunga, J., Zeuzem, S., & Herrmann, E. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.01.034 · Cited by 1,490
Diagnostic accuracy of dermoscopy
Kittler, H., Pehamberger, H., Wolff, K., & Binder, M. (2002) · The Lancet Oncology · doi:10.1016/s1470-2045(02)00679-4 · Cited by 1,349
Metadata
- Authors
- Littenberg, B., & Moses, L. E.
- Venue
- Medical Decision Making
- Publisher
- SAGE Publications
- Published
- 1993-12
- Volume
- 13
- Issue
- 4
- Pages
- 313-321
- ISSN
- 0272-989X (ISSN-L)
- 1552-681X
- OpenAlex
- W2059146824
- Cited by
- 434
- References
- 11
- FWCI
- 8.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.