The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Enhanced Modelling and Performance in Braided Pneumatic Muscle Actuators
Open accessAbstract
Pneumatic technology has been successfully applied for over two millennia. Even today, pneumatic cylinder based technology forms the keystone of many manufacturing processes where there is a need for simple, high-speed, low-cost, reliable motion. But when the system requires accurate control of position, velocity or acceleration profiles, these actuators form a far from satisfactory solution. Braided pneumatic muscle actuators (pMAs) form an interesting development of the pneumatic principle offering even higher power/weight performance, operation in a wide range of environments and accurate control of position, motion and force. This technology provides an interesting and potentially very successful alternative actuation source for robots as well as other applications. However, there are difficulties with this approach due to the following.(i)Modeling errors. Models of the force response are still nonoptimal and for good results these models are highly complex, which makes accurate design difficult.(ii)Low bandwidth—the bandwidth of the actuator—link assemblies are often considered to be too low for practical success in many applications, particularly robotics.In this paper we address these limitations and show how the performance in each area can be enhanced with overall improvements in the response and utility of the braided pMAs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement and modeling of McKibben pneumatic artificial muscles
Chou, C.-P., & Hannaford, B. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.481753 · Cited by 1,589
Cited by
Exoskeleton robots for upper-limb rehabilitation: State of the art and future prospects
Lo, H. S., & Xie, S. Q. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.10.004 · Cited by 571
Modelling of the McKibben artificial muscle: A review
Tondu, B. (2012) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x11435435 · Cited by 490
Thill, C., Etches, J., Bond, I., Potter, K., & Weaver, P. (2008) · The Aeronautical Journal · doi:10.1017/s0001924000002062 · Cited by 487
An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles
Ferris, D. P., Czerniecki, J. M., & Hannaford, B. (2005) · Journal of Applied Biomechanics · doi:10.1123/jab.21.2.189 · Cited by 376
An improved powered ankle–foot orthosis using proportional myoelectric control
Ferris, D. P., Gordon, K. E., Sawicki, G. S., & Peethambaran, A. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.05.004 · Cited by 342
Metadata
- Authors
- Davis, S., Tsagarakis, N., Canderle, J., & Caldwell, D. G.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2003-03-01
- Volume
- 22
- Issue
- 3
- Pages
- 213-227
- ISSN
- 0278-3649 (ISSN-L)
- 0000-0000
- OpenAlex
- W2111689525
- Cited by
- 177
- References
- 1
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced Modelling and Performance in Braided Pneumatic Muscle Actuators. https://app.cochat.ai/papers/10.1177/027836403128964908
- The paper
- Davis, S., Tsagarakis, N., Canderle, J., & Caldwell, D. G. (2003). Enhanced Modelling and Performance in Braided Pneumatic Muscle Actuators. The International Journal of Robotics Research. https://doi.org/10.1177/027836403128964908
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.