Determination of Optimal Measurement Configurations for Robot Calibration Based on Observability Measure
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The selection of measurement configurations in robot cali bration is investigated. The goal is to select a set of robot measurement configurations that will yield maximum ob servability of the error parameters in a defined position error model so that the effect of noise in parameter estimation can be minimized. The noise considered in this paper includes both measurement and modeling errors. An observability measure is used as a criterion for selecting measurement configurations for calibration. Experimental studies are per formed to demonstrate the importance of observability to parameter estimation and to verify its implications in robot calibration. Based on the defined observability measure, the optimal measurement configurations for robot calibration are determined for general open-loop planar mechanism and PUMA type robots.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Proceedings. 1985 IEEE International Conference on Robotics and Automation
(1985) · doi:10.1109/robot.1985 · Cited by 3,673
The singular value decomposition: Its computation and some applications
Klema, V., & Laub, A. (1980) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1980.1102314 · Cited by 1,631
Proceedings. 1988 IEEE International Conference on Robotics and Automation
(1988) · doi:10.1109/robot.1988 · Cited by 991
ASME Design Engineering Technical Conference
(1972) · Mechanism and Machine Theory · doi:10.1016/0094-114x(72)90068-7 · Cited by 121
Cited by
The Calibration Index and Taxonomy for Robot Kinematic Calibration Methods
Hollerbach, J. M., & Wampler, C. W. (1996) · The International Journal of Robotics Research · doi:10.1177/027836499601500604 · Cited by 293
Observability index selection for robot calibration
Sun, Y., & Hollerbach, J. M. (2008) · 2008 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2008.4543308 · Cited by 173
“In terms of this terminology, • Observability index O1 [10], [3] is the root of the product of the singular values:”
BackgroundOn task-oriented criteria for configurations selection in robot calibration
Carrillo, H., Birbach, O., Taubig, H., Bauml, B., Frese, U., & Castellanos, J. A. (2013) · 2013 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2013.6631090 · Cited by 20
“A second approach O D is due to Borm and Menq [2], and their proposal was based on the minimum ellipsoid's error of the estimated parameters.”
BackgroundMethodInfluential
Metadata
- Authors
- Borm, J.-H., & Meng, C.-H.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 1991-02
- Volume
- 10
- Issue
- 1
- Pages
- 51-63
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2058428974
- Cited by
- 229
- References
- 4
- FWCI
- 7.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.