CoChat

Evaluation of Random Plasma Cortisol and the Low Dose Corticotropin Test as Indicators of Adrenal Secretory Capacity in Critically Ill Patients: A Prospective Study

Open access
Venkatesh, B., Mortimer, R. H., Couchman, B., Hall, J. · 2005 · Anaesthesia and Intensive Care
Cited by 100

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

It is unclear whether a random plasma cortisol measurement and the corticotropin (ACTH) test adequately reflect glucocorticoid secretory capacity in critical illness. This study aimed to determine whether these tests provide information representative of the 24 hour period. Plasma cortisol was measured hourly for 24 hours in 21 critically ill septic patients followed by a corticotropin test with 1 μg dose administered intravenously. Serum and urine were analysed for ACTH and free cortisol respectively. Marked hourly variability in plasma cortisol was evident (coefficient of variation 8–30%) with no demonstrable circadian rhythm. The individual mean plasma cortisol concentrations ranged from 286±59 nmol/l to 796± 83 nmol/l. The 24 hour mean plasma cortisol was strongly correlated with both random plasma cortisol (r 2 0.9, P<0.0001) and the cortisol response to corticotropin (r 2 0.72, P<0.001). Only nine percent of patients increased their plasma cortisol by 250 nmol/l after corticotropin (euadrenal response). However, 35% of non-responders had spontaneous hourly rises >250 nmol/l thus highlighting the limitations of a single point corticotropin test. Urinary free cortisol was elevated (865±937 nmol) in both corticotropin responders and non-responders suggesting elevated plasma free cortisol. No significant relationship was demonstrable between plasma cortisol and ACTH. We conclude that although random cortisol measurements and the low dose corticotropin tests reliably reflect the 24 hour mean cortisol in critical illness, they do not take into account the pulsatile nature of cortisol secretion. Consequently, there is the potential for erroneous conclusions about adrenal function based on a single measurement. We suggest that caution be exercised when drawing conclusions on the adequacy of adrenal function based on a single random plasma cortisol or the corticotropin test.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0310057x0503300208

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 100

Metadata

Authors
Venkatesh, B., Mortimer, R. H., Couchman, B., & Hall, J.
Venue
Anaesthesia and Intensive Care
Published
2005-04
Volume
33
Issue
2
Pages
201-209
ISSN
  • 0310-057X (ISSN-L)
  • 1448-0271
OpenAlex
W1785629716
Cited by
100
References
7
FWCI
4.93
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Random Plasma Cortisol and the Low Dose Corticotropin Test as Indicators of Adrenal Secretory Capacity in Critically Ill Patients: A Prospective Study. https://app.cochat.ai/papers/10.1177/0310057x0503300208
The paper
Venkatesh, B., Mortimer, R. H., Couchman, B., & Hall, J. (2005). Evaluation of Random Plasma Cortisol and the Low Dose Corticotropin Test as Indicators of Adrenal Secretory Capacity in Critically Ill Patients: A Prospective Study. Anaesthesia and Intensive Care. https://doi.org/10.1177/0310057x0503300208

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.