The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Force Measurements on the Fibular Collateral Ligament, Popliteofibular Ligament, and popliteus Tendon to Applied Loads
Abstract
Background: Little information is known about the forces seen on the main individual structures of the posterolateral knee to applied loads. This information is needed to determine which structures should be reconstructed and also the relative strengths needed for reconstruction grafts. Purpose: To determine in vitro forces in the fibular collateral ligament, popliteofibular ligament, and popliteus tendon for various posterolateral knee loading conditions. Study Design: Cadaveric study. Results: The fibular collateral ligament was loaded in varus, internal rotation, and external rotation. The highest amount of force seen on the fibular collateral ligament was at 0° of knee flexion with external rotation, with the mean load response to external rotation significantly less at 90°. Fibular collateral ligament varus load response at 0°, 30°, and 60° was fairly constant, with a significant decrease at 90° compared to 30° of knee flexion. The popliteus tendon and popliteofibular ligament were loaded with an external rotation moment and were noted to have similar loading patterns. The mean load response on both the popliteus tendon and the popliteofibular ligament peaked at 60° of knee flexion. The mean popliteus tendon and popliteofibular ligament load response at 0° was significantly less than the mean load response at 30°, 60°, and 90° of knee flexion. Conclusions: High relative loads were seen on the fibular collateral ligament with varus and external rotation and on the popliteus tendon and popliteofibular ligament, with external rotation. A reciprocal relationship of load sharing in external rotation depending on knee flexion angle was revealed that has not been previously reported. The force on the fibular collateral ligament with external rotation loads was higher than the load on the popliteus complex at lower flexion angles, with the popliteus complex having higher load sharing at 60° and 90° of knee flexion. These results provide a measure of the potential for failure of these structures with joint loading and guidelines for both graft strength requirements for surgical reconstructions and postoperative rehabilitation protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Markolf, K. L., Gorek, J. F., Kabo, J. M., & Shapiro, M. S. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072040-00014 · Cited by 610
Cited by
Griffith, C. J., LaPrade, R. F., Johansen, S., Armitage, B., Wijdicks, C., & Engebretsen, L. (2009) · The American Journal of Sports Medicine · doi:10.1177/0363546509333852 · Cited by 274
Self-citation
Metadata
- Authors
- LaPrade, R. F., Tso, A., & Wentorf, F. A.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2004-10
- Volume
- 32
- Issue
- 7
- Pages
- 1695-1701
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2061456845
- Cited by
- 193
- References
- 1
- FWCI
- 3.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Force Measurements on the Fibular Collateral Ligament, Popliteofibular Ligament, and popliteus Tendon to Applied Loads. https://app.cochat.ai/papers/10.1177/0363546503262694
- The paper
- LaPrade, R. F., Tso, A., & Wentorf, F. A. (2004). Force Measurements on the Fibular Collateral Ligament, Popliteofibular Ligament, and popliteus Tendon to Applied Loads. The American Journal of Sports Medicine. https://doi.org/10.1177/0363546503262694
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.