The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
The Effects of Augmentation with Swine Small Intestine Submucosa on Tendon Healing under Tension: Histologic and Mechanical Evaluations in Sheep
Abstract
Background: Rotator cuff failure after surgery may be attributed to inferior tissue healing properties that result from repetitive cyclic loading during early rehabilitation. Enhancing the biological healing process may reduce the incidence of failures after rotator cuff repairs. Hypothesis: Augmentation of rotator cuff tissue using swine small intestine submucosa in a sheep model will improve the rate and quality of tissue repair. Study Design: Controlled laboratory study. Methods: We resected and reattached 26 sheep infraspinatus tendons under tension, with 13 animals receiving a small intestine submucosa patch (augmented group). Animals were sacrificed at 12 weeks, and biomechanical testing and histologic evaluation were performed. Biomechanical testing was completed in 10 tendons from each group. Specimens were loaded to failure at a constant displacement to obtain the load deformation curve used to calculate load to failure and stiffness of the healed bone-tendon interface. Histologic testing addressed tissue healing at the bone-tendon interface. Results: The load-to-failure data did not indicate a significant difference between the augmented and nonaugmented groups (1252 ± 402 N vs 985 ± 459 N, respectively; P >. 05). However, the augmented group had significantly better stiffness than the nonaugmented group (215 ± 44 N/mm vs 154 ± 63 N/mm, respectively; P =. 03). Histologic data revealed that the infraspinatus tendon in all specimens inserted into the bone through a zone of fibrocartilage, although none of the patches were intact. Conclusion: Although there were no differences in the load-to-failure data between the 2 groups, the statistically significant improvement in stiffness for the augmented group is clinically relevant. Stiffness is the biomechanical parameter representing the tissue response to subdestructive loads seen with early rehabilitation. Augmenting the repair with a collagen matrix improved the early healing characteristics of the repair construct. Clinical Relevance: Enhancing the biological process of tendon healing under tension by using a collagen matrix patch may improve the ultimate success of rotator cuff repair.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“higher levels of inflammatory markers in blood are associated with a greater loss of muscle mass and strength, accelerated loss of mobility, lower-extremity performance and physical activity, and depression in older individuals”
From Inflammageing: chronic inflammation in ageing, cardiovascular disease, and frailty (2018) · cites this paper as [224]
Citations
Cites
Galatz, L. M., Ball, C. M., Teefey, S. A., Middleton, W. D., & Yamaguchi, K. (2004) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200402000-00002 · Cited by 2,144
Repairs of the rotator cuff. Correlation of functional results with integrity of the cuff.
Harryman, D. T., Mack, L. A., Wang, K. Y., Jackins, S. E., Richardson, M. L., & Matsen, F. A. (1991) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199173070-00004 · Cited by 1,255
Results of a second attempt at surgical repair of a failed initial rotator-cuff repair.
DeOrio, J. K., & Cofield, R. H. (1984) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-198466040-00011 · Cited by 925
Mechanical strength of repairs of the rotator cuff
Gerber, C., Schneeberger, A. G., Beck, M., & Schlegel, U. J. (1994) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.76b3.8175836 · Cited by 689
Functional and Anatomical Results After Rotator Cuff Repair
Gazielly, D. F., Gleyze, P., & Montagnon, C. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199407000-00009 · Cited by 552
Experimental Rotator Cuff Repair. A Preliminary Study*
Gerber, C., Schneeberger, A. G., Perren, S. M., & Nyffeler, R. W. (1999) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199909000-00009 · Cited by 464
Gartsman, G. M. (1997) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199705000-00011 · Cited by 284
Tissue-Engineered Rotator Cuff Tendon Using Porcine Small Intestine Submucosa
Déjardin, L. M., ARNOCZKY, S. P., Ewers, B. J., Haut, R. C., & Clarke, R. B. (2001) · The American Journal of Sports Medicine · doi:10.1177/03635465010290021001 · Cited by 275
Repair of Full Thickness Rotator Cuff Tears Gender, Age, and Other Factors Affecting Outcome
Romeo, A. A., Hang, D. W., Bach, B. R., & Shott, S. (1999) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199910000-00031 · Cited by 253
Cyclic loading of transosseous rotator cuff repairs: Tension overload as a possible cause of failure
Burkhart, S. S., Johnson, T. C., Wirth, M. A., & Athanasiou, K. A. (1997) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(97)90151-1 · Cited by 252
Research works printed but not linked: 3
- Lewis CW, 2001, Biomed Sci Instrum, 37, 263
- MatsenFAIII, ArntzCT, LippittSB. Rotatorcuff. In: RockwoodCAJr, MatsenFAIII, eds. The Shoulder. 2nd ed. Philadelphia, Pa: WB Saunders; 1998:755–839.
- Schlegel TF, 25th Annual Meeting American Orthopaedic Society of Sports Medicine
Cited by
Sorted by citations
Inflammageing: chronic inflammation in ageing, cardiovascular disease, and frailty
Ferrucci, L., & Fabbri, E. (2018) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0064-2 · Cited by 3,690
Novel Nanofiber-Based Scaffold for Rotator Cuff Repair and Augmentation
Moffat, K. L., Kwei, A. S.-P., Spalazzi, J. P., Doty, S. B., Levine, W. N., & Lu, H. H. (2008) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0014 · Cited by 307
Rodeo, S. A., Potter, H. G., Kawamura, S., Turner, A. S., Kim, H. J., & Atkinson, B. L. (2007) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200711000-00021 · Cited by 292
Self-citationTendon augmentation grafts: a systematic review
Longo, U. G., Lamberti, A., Maffulli, N., & Denaro, V. (2010) · British Medical Bulletin · doi:10.1093/bmb/ldp051 · Cited by 280
Biological Augmentation of Rotator Cuff Tendon Repair
Kovacevic, D., & Rodeo, S. A. (2008) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-007-0112-4 · Cited by 278
Metadata
- Authors
- Schlegel, T. F., Hawkins, R. J., Lewis, C. W., Motta, T., & Turner, A. S.
- Affiliations
- Steadman Clinic (US)
- Colorado State University (US)
- ORCID
- Hawkins, Richard J.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2006-02
- Volume
- 34
- Issue
- 2
- Pages
- 275-280
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2133103125
- Cited by
- 126
- References
- 16
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 2 · 2023: 4 · 2022: 3 · 2021: 8 · 2020: 4 · 2019: 5 · 2018: 3 · 2017: 7 · 2016: 11 · 2015: 8 · 2014: 7 · 2013: 5 · 2012: 7
- FWCI
- 6.34
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The American Journal of Sports Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Shoulder Injury and Treatment
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Tendon Structure and Treatment
- Health Sciences › Medicine › Surgery › Orthopedic Surgery and Rehabilitation
- Keywords
- small intestinal submucosa, tendon healing, rotator cuff repair, tendon augmentation, infraspinatus tendon, tendon-bone interface, stiffness, load to failure, cyclic loading, early rehabilitation, sheep model
- MeSH terms
- Animals, Arthroplasty, Biomechanical Phenomena, Disease Models, Animal, Intestinal Mucosa, Intestine, Small, Sheep, Swine, Tendon Injuries, Tendons, Transplantation, Heterologous, Wound Healing, Rotator Cuff, Treatment Failure, Models, Animal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review