CoChat

Arthroscopically Pertinent Landmarks for Tunnel Positioning in Single-Bundle and Double-Bundle Anterior Cruciate Ligament Reconstructions

Ziegler, Connor G., Pietrini, Sean D., Westerhaus, Benjamin D., Anderson, Colin J., Wijdicks, Coen A., Johansen, Steinar, Engebretsen, Lars, LaPrade, Robert F. · 2011 · The American Journal of Sports Medicine
Cited by 199

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: Quantification of the overall anterior cruciate ligament (ACL) and anteromedial (AM) and posterolateral (PL) bundle centers in respect to arthroscopically pertinent bony and soft tissue landmarks has not been thoroughly assessed. Hypothesis: A standardized anatomical measurement method can quantitate the locations of the ACL and AM and PL bundle centers in reference to each other and anatomical landmarks. Study Design: Descriptive laboratory study. Methods: Quantification of the ACL and its bundle attachments was performed on 11 cadaveric knees using a radio frequency-tracking device. Results: The tibial ACL attachment center was 7.5 mm medial to the anterior horn of the lateral meniscus, 13.0 mm anterior to the retro-eminence ridge, and 10.5 mm posterior to the ACL ridge. The femoral ACL attachment center was 1.7 mm proximal to the bifurcate ridge and 6.1 mm posterior to the lateral intercondylar ridge. The tibial AM attachment center was 8.3 mm medial to the anteromedial aspect of the lateral meniscus anterior horn, 17.8 mm anterior to the retro-eminence ridge, and 5.6 mm posterior to the ACL ridge. The femoral AM attachment center was 4.8 mm proximal to the bifurcate ridge and 7.1 mm posterior to the lateral intercondylar ridge. The tibial PL bundle attachment center was 6.6 mm medial to the posteromedial aspect of the lateral meniscus anterior horn, 10.8 mm anteromedial to the root attachment of the lateral meniscus posterior horn, and 8.4 mm anterior to the retro-eminence ridge. The femoral PL bundle attachment center was 5.2 mm distal to the bifurcate ridge and 3.6 mm posterior to the lateral intercondylar ridge. Conclusion: The authors developed a comprehensive compilation of measurements of arthroscopically pertinent bony and soft tissue landmarks that quantitate the ACL and its individual bundle attachment centers on the tibia and femur. Clinical Relevance: These clinically relevant arthroscopic landmarks may enhance single- and double-bundle ACL reconstructions through improved tunnel placement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0363546510387511

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 199

Metadata

Authors
Ziegler, C. G., Pietrini, S. D., Westerhaus, B. D., Anderson, C. J., Wijdicks, C. A., Johansen, S., Engebretsen, L., & LaPrade, R. F.
Venue
The American Journal of Sports Medicine
Published
2010-12-20
Volume
39
Issue
4
Pages
743-752
ISSN
  • 0363-5465 (ISSN-L)
  • 1552-3365
OpenAlex
W2017699140
Cited by
199
References
1
FWCI
8.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Arthroscopically Pertinent Landmarks for Tunnel Positioning in Single-Bundle and Double-Bundle Anterior Cruciate Ligament Reconstructions. https://app.cochat.ai/papers/10.1177/0363546510387511
The paper
Ziegler, C. G., Pietrini, S. D., Westerhaus, B. D., Anderson, C. J., Wijdicks, C. A., Johansen, S., Engebretsen, L., & LaPrade, R. F. (2011). Arthroscopically Pertinent Landmarks for Tunnel Positioning in Single-Bundle and Double-Bundle Anterior Cruciate Ligament Reconstructions. The American Journal of Sports Medicine. https://doi.org/10.1177/0363546510387511

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.