Background: The Goutallier classification of fatty infiltration of the rotator cuff was developed for use in axial computed tomography arthrography. Now the Goutallier classification is being used with magnetic resonance imaging (MRI). Not only is there debate on the validity of the use of this system in MRI, but current literature is unclear as to the clinical use of the Goutallier classification. Hypothesis: There will be significant inter- and intraobserver variability of the Goutallier classification grading system for patients with chronic rotator cuff tears. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: An online database consisting of 35 single MRI images from 35 patients with chronic rotator cuff tears was designed and sent to members of the American Shoulder and Elbow Society. Surgeons were asked to identify the stage of rotator cuff fatty infiltration using the Goutallier classification system. Thirty surgeons responded and completed the survey in its entirety. At a minimum of 2 months later, 28 of the 30 initial respondents completed evaluations of the same online database. The responding surgeons were divided dichotomously according to their demographics and the interobserver reliability of the groups compared. A kappa analysis was performed to determine inter- and intraobserver reliability using 95% confidence intervals (95% CIs). A simplified 3-tiered classification was proposed combining Goutallier grades 0 and 1 as well as grades 2 and 3. Results: Statistical analysis of all respondent data demonstrated moderate intraobserver variability with a κ value of 0.56 (95% CI, 0.53-0.60). In addition, moderate interobserver variability was shown with a κ value of 0.43 (range, 0.16-0.74). With the simplified classification, intraobserver reliability was 0.70 (95% CI, 0.66-0.74) and interobserver reliability was 0.61 (range, 0.21-0.87). Correlation analysis showed no correlation with the presence or absence of fellowship training or board certification with either the Goutallier classification or the proposed modification ( P > .05). Sports versus shoulder/elbow fellows had statistically better intraobserver variability (κ = 0.63 vs 0.50) with the Goutallier classification. Years in practice was negatively correlated with the level of agreement for both classifications (– r value, P < .05). The number of rotator cuff repairs performed per year negatively correlated with the level of agreement in the proposed modification only ( r = −0.44, P = .022). Percent of practice dedicated to the shoulder did not correlate significantly with either classification ( P > .05). Conclusion: There is significant inter- and intraobserver variability observed among experienced shoulder surgeons using the Goutallier classification for assessing fatty infiltration of the rotator cuff muscles after chronic rotator cuff tears. Respondents were more likely to agree with themselves than with other respondents. A simplification of the MRI classification system is proposed that takes into consideration the variability determined by this study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148 · cited 1×
“When this classification system is reduced to 3 grades, both inter- and intraobserver reliabilities can be characterized as being substantial.(10) Furthermore, we showed that only type of fellowship training correlated with intraobserver reliability, whereas years in practice negatively correlated with intraobserver r…”
BackgroundAsymptotic Theory of Certain "Goodness of Fit" Criteria Based on Stochastic Processes
Anderson, T. W., & Darling, D. A. (1952) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177729437 · Cited by 3,542 · cited 2×
“The levels of agreement were tested for normality using the Anderson-Darling Test for Normality.(1) All data from the respondents can be found in the Appendix (available in the online version of this article at http://ajs.”
MethodFatty muscle degeneration in cuff ruptures. Pre- and postoperative evaluation by CT scan.
GOUTALLIER, D., Postel, J.-M., BERNAGEAU, J., Lavau, L., & Voisin, M. C. (1994) · PubMed · Cited by 2,554
Fatty Muscle Degeneration in Cuff Ruptures: Pre- and Postoperative Evaluation by CT Scan
Goutallier, D., Postel, J.-M., Bernageau, J., Lavau, L., & Voisin, M.-C. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199407000-00014 · Cited by 2,150 · cited 1×
“Such attention has produced an ongoing interest in evaluating the reliability of the grading of fatty infiltration of the rotator cuff.(3,6,11,15,19) A study done by Fuchs et al(3) was the first to look at the reliability of their classification scheme for assessing fatty infiltration.”
BackgroundFuchs, B., Weishaupt, D., Zanetti, M., Hodler, J., & Gerber, C. (1999) · Journal of Shoulder and Elbow Surgery · doi:10.1016/s1058-2746(99)90097-6 · Cited by 1,413 · cited 1×
“Such attention has produced an ongoing interest in evaluating the reliability of the grading of fatty infiltration of the rotator cuff.(3,6,11,15,19) A study done by Fuchs et al(3) was the first to look at the reliability of their classification scheme for assessing fatty infiltration.”
BackgroundGladstone, J. N., Bishop, J. Y., Lo, I. K. Y., & Flatow, E. L. (2007) · The American Journal of Sports Medicine · doi:10.1177/0363546506297539 · Cited by 967 · cited 1×
“In addition, it has been shown that even after a successful rotator cuff repair (anatomic and clinical), fatty infiltration does not improve in patients.(5,12,17) Because of the clinical implications of fatty infiltration in rotator cuff tears, there have been several efforts to ensure that the Goutallier scheme is re…”
BackgroundGoodness of Fit: Social Work Education and Practice in Health Care
Bronstein, L., Kovacs, P., & Vega, A. (2007) · Social Work in Health Care · doi:10.1300/j010v45n02_04 · Cited by 785
A critical discussion of intraclass correlation coefficients
Müller, R., & Büttner, P. (1994) · Statistics in Medicine · doi:10.1002/sim.4780132310 · Cited by 714 · cited 1×
“The ICC is not as effective as k in terms of measuring reliability because it does not consider chance and typically overestimates inter- and intrareliability values.(14) Using the ICC to determine our intraobserver reliability would have computed out to a value of 0.”
MethodGerber, C., Schneeberger, A. G., Hoppeler, H., & Meyer, D. C. (2007) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2007.02.122 · Cited by 340
Oh, J. H., Kim, S. H., Ji, H. M., Jo, K. H., Bin, S. W., & Gong, H. S. (2009) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2008.08.010 · Cited by 340
Cited by
Battaglia, P. J., Maeda, Y., Welk, A., Hough, B., & Kettner, N. (2014) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2013.12.010 · Cited by 128
Metadata
- Authors
- Slabaugh, M. A., Friel, N. A., Karas, V., Romeo, A. A., Verma, N. N., & Cole, B. J.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2012-07-02
- Volume
- 40
- Issue
- 8
- Pages
- 1728-1734
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2128678190
- Cited by
- 177
- References
- 17
- FWCI
- 6.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interobserver and Intraobserver Reliability of the Goutallier Classification Using Magnetic Resonance Imaging: Proposal of a Simplified Classification System to Increase Reliability. https://app.cochat.ai/papers/10.1177/0363546512452714
- The paper
- Slabaugh, M. A., Friel, N. A., Karas, V., Romeo, A. A., Verma, N. N., & Cole, B. J. (2012). Interobserver and Intraobserver Reliability of the Goutallier Classification Using Magnetic Resonance Imaging: Proposal of a Simplified Classification System to Increase Reliability. The American Journal of Sports Medicine. https://doi.org/10.1177/0363546512452714
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.