Femoral Suspension Devices for Anterior Cruciate Ligament Reconstruction: Do Adjustable Loops Lengthen?
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Cortical suspension devices are commonly used for femoral graft fixation during anterior cruciate ligament (ACL) reconstructive surgery. Adjustable-length fixation devices provide technical advantages over fixed-length loops but may be more susceptible to lengthening during cyclic loading. Hypothesis: Both fixed-length and adjustable-length femoral cortical suspension devices would withstand ultimate loads greater than those normally experienced by the native ACL and would prevent clinically significant lengthening during prolonged cyclic loading. Study Design: Controlled laboratory study. Methods: Mechanical testing was performed on 3 ACL graft cortical suspensory devices by use of an extended cyclic loading (4500 cycles at 10-250 N) and pull-to-failure protocol. Two adjustable-length devices were additionally tested with the free suture ends tied. Results: Total displacement after 4500 cycles of tensioning at variable loads (expressed as mean ± SD) was 42.45 mm (±7.01 mm) for the Arthrex TightRope RT, 5.76 mm (±0.35 mm) for the Biomet ToggleLoc, and 1.34 mm (±0.03 mm) for the Smith & Nephew EndoButton CL Ultra ( P < .001). The Arthrex TightRope reached clinical failure of 3 mm lengthening after fewer cycles (1349 ± 316) than the Biomet ToggleLoc (2576 ± 73) ( P < .001). The Smith & Nephew EndoButton did not reach clinical failure during cyclic testing. With the free suture ends tied, after 4500 cycles, the Arthrex TightRope had a significant decrease in lengthening to 13.36 ± 1.86 mm ( P < .037) There was also a significant difference in ultimate load between the TightRope (809.11 ± 52.94 N) and the other 2 constructs ( P < .001). Conclusion: The ultimate load of all graft-fixation devices exceeded the forces likely to be experienced in a patient’s knee during the early postoperative rehabilitation period. However, the adjustable-length fixation devices experienced a clinically significant increase in loop lengthening during cyclic testing. This lengthening is partially caused by suture slippage into the adjustable-length loop. Clinical Relevance: Adjustable-length ACL graft cortical suspension devices lengthen under cyclic loads because free suture ends are pulled into the adjustable loop. This may allow for graft-fixation device lengthening during the acute postoperative period.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Animal models for implant biomaterial research in bone: A review
AO Research Institute, A. F., Pearce, A., Richards, R., Milz, S., Schneider, E., & Pearce, S. (2007) · European Cells and Materials · doi:10.22203/ecm.v013a01 · Cited by 1,289
Rodeo, S. A., Kawamura, S., Kim, H.-J., Dynybil, C., & Ying, L. (2006) · The American Journal of Sports Medicine · doi:10.1177/0363546506290059 · Cited by 238 · cited 2×
“Slippage negatively affects both postoperative healing and clinical outcomes because of increased graft laxity.(20,31) The clinically relevant amount of allowable graft-fixation device construct lengthening is not known.”
Background
Metadata
- Authors
- Barrow, A. E., Pilia, M., Guda, T., Kadrmas, W. R., & Burns, T. C.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2013-10-24
- Volume
- 42
- Issue
- 2
- Pages
- 343-349
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2158113645
- Cited by
- 158
- References
- 2
- FWCI
- 7.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Femoral Suspension Devices for Anterior Cruciate Ligament Reconstruction: Do Adjustable Loops Lengthen? https://app.cochat.ai/papers/10.1177/0363546513507769
- The paper
- Barrow, A. E., Pilia, M., Guda, T., Kadrmas, W. R., & Burns, T. C. (2014). Femoral Suspension Devices for Anterior Cruciate Ligament Reconstruction: Do Adjustable Loops Lengthen? The American Journal of Sports Medicine. https://doi.org/10.1177/0363546513507769
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.