CoChat

Anterolateral Tenodesis or Anterolateral Ligament Complex Reconstruction: Effect of Flexion Angle at Graft Fixation When Combined With ACL Reconstruction

Inderhaug, Eivind, Stephen, Joanna M., Williams, Andy, Amis, Andrew A. · 2017 · The American Journal of Sports Medicine
Cited by 186

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

Background: Despite numerous technical descriptions of anterolateral procedures, knowledge is limited regarding the effect of knee flexion angle during graft fixation. Purpose: To determine the effect of knee flexion angle during graft fixation on tibiofemoral joint kinematics for a modified Lemaire tenodesis or an anterolateral ligament (ALL) complex reconstruction combined with anterior cruciate ligament (ACL) reconstruction. Study Design: Controlled laboratory study. Methods: Twelve cadaveric knees were mounted in a test rig with kinematics recorded from 0° to 90° flexion. Loads applied to the tibia were 90-N anterior translation, 5-N·m internal tibial rotation, and combined 90-N anterior force and 5-N·m internal rotation. Intact, ACL-deficient, and combined ACL plus anterolateral-deficient states were tested, and then ACL reconstruction was performed and testing was repeated. Thereafter, modified Lemaire tenodeses and ALL procedures with graft fixation at 0°, 30°, and 60° of knee flexion and 20-N graft tension were performed combined with the ACL reconstruction, and repeat testing was performed throughout. Repeated-measures analysis of variance and Bonferroni-adjusted t tests were used for statistical analysis. Results: In combined ACL and anterolateral deficiency, isolated ACL reconstruction left residual laxity for both anterior translation and internal rotation. Anterior translation was restored for all combinations of ACL and anterolateral procedures. The combined ACL reconstruction and ALL procedure restored intact knee kinematics when the graft was fixed in full extension, but when the graft was fixed in 30° and 60°, the combined procedure left residual laxity in internal rotation ( P = .043). The combined ACL reconstruction and modified Lemaire procedure restored internal rotation regardless of knee flexion angle at graft fixation. When the combined ACL reconstruction and lateral procedure states were compared with the ACL-only reconstructed state, a significant reduction in internal rotation laxity was seen with the modified Lemaire tenodesis but not with the ALL procedure. Conclusion: In a knee with combined ACL and anterolateral ligament injuries, the modified Lemaire tenodesis combined with ACL reconstruction restored normal laxities at all angles of flexion for graft fixation (0°, 30°, or 60°), with 20 N of tension. The combined ACL and ALL procedure restored intact knee kinematics when tensioned in full extension. Clinical Relevance: In combined anterolateral procedure plus intra-articular ACL reconstruction, the knee flexion angle is important when fixing the graft. A modified Lemaire procedure restored intact knee laxities when fixation was performed at 0°, 30°, or 60° of flexion. The ALL procedure restored normal laxities only when fixation occurred in full extension.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0363546517724422

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Inderhaug, E., Stephen, J. M., Williams, A., & Amis, A. A.
Venue
The American Journal of Sports Medicine
Published
2017-09-12
Volume
45
Issue
13
Pages
3089-3097
ISSN
  • 0363-5465 (ISSN-L)
  • 1552-3365
OpenAlex
W2754500926
Cited by
186
References
22
FWCI
13.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.