Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 210

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Concentrations of Blood Components in Commercial Platelet-Rich Plasma Separation Systems: A Review of the Literature

Open access
Oudelaar, Bart W., Peerbooms, Joost C., Huis in ‘t Veld, Rianne, Vochteloo, Anne J.H. · 2019 · The American Journal of Sports Medicine

Abstract

Background: Platelet-rich plasma (PRP) has proven to be a very safe therapeutic option in the treatment of tendon, muscle, bone, and cartilage injuries. Currently, several commercial separation systems are available for the preparation of PRP. The concentrations of blood components in PRP among these separation systems vary substantially. Purpose: To systematically review and evaluate the differences between the concentrations of blood components in PRP produced by various PRP separation systems. Study Design: Systematic review. Methods: MEDLINE/PubMed, the Cochrane Central Register of Controlled Trials (CENTRAL), and EMBASE were searched for studies that compared the concentrations of blood components and growth factors in PRP between various separation systems and studies that reported on the concentrations of blood components and growth factors of single separation systems. The primary outcomes were platelet count, leukocyte count, and concentration of growth factors (eg, platelet-derived growth factor–AB [PDGF-AB], transforming growth factor–β1 [TGF-β1], and vascular endothelial growth factor [VEGF]). Furthermore, the preparation protocols and prices of the systems were compared. Results: There were 1079 studies found, of which 19 studies were selected for inclusion in this review. The concentrations of platelets and leukocytes in PRP differed largely between, and to a lesser extent within, the studied PRP separation systems. Additionally, large differences both between and within the studied PRP separation systems were found for all the growth factors. Furthermore, preparation protocols and prices varied widely between systems. Conclusion: There is a large heterogeneity between PRP separation systems regarding concentrations of platelets, leukocytes, and growth factors in PRP. The choice for the most appropriate type of PRP should be based on the specific clinical field of application. As the ideal concentrations of blood components and growth factors for the specific fields of application are yet to be determined for most of the fields, future research should focus on which type of PRP is most suitable for the specific field.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0363546517746112

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 210

Metadata

Authors
Oudelaar, B. W., Peerbooms, J. C., Huis in ‘t Veld, R., & Vochteloo, A. J. H.
Venue
The American Journal of Sports Medicine
Published
2018-01-16
Volume
47
Issue
2
Pages
479-487
ISSN
  • 0363-5465 (ISSN-L)
  • 1552-3365
OpenAlex
W2782831496
Cited by
210
References
1
FWCI
27.58
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Concentrations of Blood Components in Commercial Platelet-Rich Plasma Separation Systems: A Review of the Literature. https://app.cochat.ai/papers/10.1177/0363546517746112
The paper
Oudelaar, B. W., Peerbooms, J. C., Huis in ‘t Veld, R., & Vochteloo, A. J. H. (2019). Concentrations of Blood Components in Commercial Platelet-Rich Plasma Separation Systems: A Review of the Literature. The American Journal of Sports Medicine. https://doi.org/10.1177/0363546517746112

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.