The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Meniscal tears: The effect of meniscectomy and of repair on intraarticular contact areas and stress in the human knee: A preliminary report
Abstract
The role of the meniscus in load transmission across the knee has long been a subject of debate. In this study, we examined the biomechanical consequences of the operative treatments for bucket-handle and pe ripheral meniscal tears. Contact areas and instanta neous intraarticular pressure distributions were meas ured in two groups of human cadaver knees. In Group I, consisting of four knees, we created a bucket-handle tear involving the inner one-third of the meniscus, followed by partial, and then total meniscec tomy. Knees were tested in an Instron testing machine after each procedure, using a 400 pound load at 0° or 30° flexion. Contact areas and local stresses were measured using Prescale, a pressure-sensitive film. After partial meniscectomy, contact areas decreased approximately 10%, and peak local contact stresses (PLCS) increased approximately 65%. After total men iscectomy, contact areas decreased approximately 75%, and PLCS increased approximately 235%. In Group II, consisting of three additional knees, we created a 2 cm peripheral tear of the posterior meniscal horn, followed by open repair, arthroscopic repair, seg mental, and then total meniscectomy. Repair of the tear was accomplished with either vertically placed sutures by an open technique or horizontally placed sutures by an arthroscopic technique. Knees were tested in the neutral position in the Instron machine and contact areas and local stresses measured using Prescale. PLCSs and contact areas were found to be the same using either repair technique. There was, however, a 110% increase in PLCS after segmental meniscectomy of that portion of the meniscus involved in the peripheral tear. These data suggest that the meniscus does have a weightbearing role. Contact stresses increased in pro portion to the amount of meniscus removed and the degree to which the structure of the meniscus was disrupted. Furthermore, there was no difference in the weightbearing characteristics of the meniscus when repaired by open versus arthroscopic technique when the knee is loaded at 0° flexion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Femorotibial weight-bearing areas. Experimental determination
Maquet, P., Van de Berg, A., & Simonet, J. (1975) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197557060-00005 · Cited by 139
Cited by
Tibial meniscal dynamics using three-dimensional reconstruction of magnetic resonance images
Thompson, W. O., Thaete, F. L., Fu, F. H., & Dye, S. F. (1991) · The American Journal of Sports Medicine · doi:10.1177/036354659101900302 · Cited by 391
Self-citation
Metadata
- Authors
- Baratz, M. E., Fu, F. H., & Mengato, R.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 1986-07
- Volume
- 14
- Issue
- 4
- Pages
- 270-275
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2036568969
- Cited by
- 830
- References
- 1
- FWCI
- 1.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Meniscal tears: The effect of meniscectomy and of repair on intraarticular contact areas and stress in the human knee: A preliminary report. https://app.cochat.ai/papers/10.1177/036354658601400405
- The paper
- Baratz, M. E., Fu, F. H., & Mengato, R. (1986). Meniscal tears: The effect of meniscectomy and of repair on intraarticular contact areas and stress in the human knee: A preliminary report. The American Journal of Sports Medicine. https://doi.org/10.1177/036354658601400405
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.