Magnetic resonance imaging of the knee
The DOI matches its Crossref record.
Abstract
Magnetic resonance imaging (MRI) is an accepted non invasive modality for evaluation of soft tissue pathology without exposure to ionizing radiation. Current appli cations demonstrate excellent visualization of the anat omy and pathology of various organs. Preliminary stud ies in the knee reveal fine resolution of anatomy and pathology involving the meniscus. The purpose of this study is to determine a prospective correlation between MRI scans and actual meniscal pathology as docu mented at the time of arthroscopy. MRI scans were obtained in 155 patients, on 156 knees (one patient with bilateral scans), with 86 patients (87 knees) even tually undergoing diagnostic and operative videoar throscopy performed by the same surgeon (DWJ). All images were obtained on the same high-resolution 1.5 Tesla GE Signa Magnetic Resonance Scanner with the same radiologist performing all readings (PEB). The knees were studied in the coronal and sagittal plane using a spin echo sequence and 5 mm slice thick nesses. The menisci were described as having Grade 1, 2, or 3 changes, with Grade 3 reserved for complete tears. Using arthroscopy as the diagnostic standard, the accuracy of MRI in diagnosing medial and lateral meniscal tears was 93.1 % and 96.6%, respectively with a Grade 3 MRI reading. For tears of the ACL, the accuracy was 96.6% as confirmed at arthroscopy. Five tears of the PCL were also documented by MRI and correlated with clinical evaluation. Other abnormalities seen were articular cartilage and osteochondral de fects, bone tumors, tibial plateau fractures, Baker's cysts, and meniscal cysts. The MRI scan is a highly accurate, noninvasive modality for documentation of meniscal pathology as well as cruciate ligament tears in the knee.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bien, N., Rajpurkar, P., Ball, R. L., Irvin, J., Park, A., Jones, E., Bereket, M., Patel, B. N., Yeom, K. W., Shpanskaya, K., et al. (2018) · PLOS Medicine · doi:10.1371/journal.pmed.1002699 · Cited by 734
Jackson, D. W., Windler, G. E., & Simon, T. M. (1990) · The American Journal of Sports Medicine · doi:10.1177/036354659001800101 · Cited by 387
Self-citationSpindler, K. P., Schils, J. P., Bergfeld, J. A., Andrish, J. T., Weiker, G. G., Anderson, T. E., Piraino, D. W., Richmond, B. J., & Medendorp, S. V. (1993) · The American Journal of Sports Medicine · doi:10.1177/036354659302100412 · Cited by 272
Metadata
- Authors
- Jackson, D. W., Jennings, L. D., Maywood, R. M., & Berger, P. E.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 1988-01
- Volume
- 16
- Issue
- 1
- Pages
- 29-38
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2008963097
- Cited by
- 210
- References
- 0
- FWCI
- 19.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic resonance imaging of the knee. https://app.cochat.ai/papers/10.1177/036354658801600105
- The paper
- Jackson, D. W., Jennings, L. D., Maywood, R. M., & Berger, P. E. (1988). Magnetic resonance imaging of the knee. The American Journal of Sports Medicine. https://doi.org/10.1177/036354658801600105
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.