The DOI matches its Crossref record.
The biochemical and histological effects of artificial ligament wear particles: In vitro and in vivo studies
Abstract
Growing evidence suggests that biochemical mecha nisms play a role in the pathogenesis of arthritis. Car tilaginous wear particles have been shown to induce destructive enzymes and cytokines. To assess the biocompatibility of artificial ACL replacements, the ef fects of wear particles from the following ligaments were analyzed biochemically and histologically: GORE- TEX, Stryker Dacron Ligament Prosthesis, Versigraft carbon, Kennedy LAD, Xenograft, Leeds-Keio, and hu man patellar tendon allograft. Ligaments were frozen and ground to produce wear particles similar to those seen clinically and were added to lapine synovial cell cultures. The resulting conditioned medium was ana lyzed for collagenase, gelatinase, and chondrocyte ac tivating factor (CAF) production. All of the ligaments induced significantly elevated enzyme and CAF production by the synoviocytes, with Xenograft and carbon inducing significantly higher en zyme levels than those of the other five ligaments. Five milligrams of wear particles were injected into the knees of 4 kg to 5 kg rabbits that were analyzed histologically after 14 weeks. Wear particles accumu lated in the periarticular synovial folds and induced modest to severe macrophage infiltration in the syno vium. A hypothetical model explaining the role of artifi cial ligament wear particles in the pathogenesis of arthritis is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Navarro, M., Michiardi, A., Castaño, O., & Planell, J. A. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0151 · Cited by 1,513
Tissue Engineering of Ligaments
Vunjak-Novakovic, G., Altman, G., Horan, R., & Kaplan, D. L. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140037 · Cited by 346
Ligament tissue engineering: An evolutionary materials science approach
Laurencin, C. T., & Freeman, J. W. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.073 · Cited by 304
Analysis of Retrieved Polymer Fiber Based Replacements for the ACL
Guidoin, M.-F., Marois, Y., Bejui, J., Poddevin, N., King, M. W., & Guidoin, R. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00114-9 · Cited by 197
Metadata
- Authors
- Olson, E. J., Kang, J. D., Fu, F. H., Georgescu, H. I., Mason, G. C., & Evans, C. H.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 1988-11
- Volume
- 16
- Issue
- 6
- Pages
- 558-570
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2063539658
- Cited by
- 184
- References
- 0
- FWCI
- 2.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The biochemical and histological effects of artificial ligament wear particles: In vitro and in vivo studies. https://app.cochat.ai/papers/10.1177/036354658801600602
- The paper
- Olson, E. J., Kang, J. D., Fu, F. H., Georgescu, H. I., Mason, G. C., & Evans, C. H. (1988). The biochemical and histological effects of artificial ligament wear particles: In vitro and in vivo studies. The American Journal of Sports Medicine. https://doi.org/10.1177/036354658801600602
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.