The strength of the central third patellar. tendon graft: A biomechanical study
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Thirty-seven bone-patellar tendon-bone composite grafts from the knees of 21 human cadavers were tested to failure. Average donor age was 28 years. The composites were divided into 4 groups: 3 groups with 10 grafts (5 pairs) and 1 group with 7 grafts from 6 donors. In Group 1 we tested 10- versus 15-mm wide grafts that were used without twisting; Group II, 10- mm wide grafts without twisting versus 10-mm wide grafts that were twisted 90°; Group III, 10-mm wide grafts twisted 90° versus 10-mm wide grafts twisted 180°; and Group IV, 10- versus 7-mm wide grafts that were not twisted. The tests were performed using a newly described potting technique and clamp system and a servohydraulic testing machine with an elongation rate of 5 cm/sec. The results of this study suggest that the central third of the patellar tendon is stronger than previously re ported. The mean ultimate load of a 15-mm bone- patellar tendon-bone composite was 4389 N (±708); of the 10-mm wide composites, 2977 N (±516); and of the 7-mm composites, 2238 N (±316). Twisting the graft 90° increased the strength (P < 0.05). Further twisting to 180° had no significant effect compared with twisting 90°. This study supports the practice of using smaller (10 mm) bone-patellar tendon-bone grafts to avoid the potential complications of patellar fracture and graft impingement in the notch.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions.
Noyes, F. R., Butler, D. L., Grood, E. S., Zernicke, R. F., & Hefzy, M. S. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466030-00005 · Cited by 1,524
The Cruciate Ligaments of the Knee Joint: Anatomical. Functional and Experimental Analysis
Girgis, F. G., Marshall, J. L., & MONA JEM, A. R. S. A. (1975) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197501000-00033 · Cited by 1,485
Ligamentous restraints to anterior-posterior drawer in the human knee. A biomechanical study.
Butler, D. L., Noyes, F. R., & Grood, E. S. (1980) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198062020-00013 · Cited by 1,272
Woo, S. L.-Y., Hollis, J. M., Adams, D. J., Lyon, R. M., & Takai, S. (1991) · The American Journal of Sports Medicine · doi:10.1177/036354659101900303 · Cited by 1,196
The strength of the anterior cruciate ligament in humans and Rhesus monkeys
Noyes, F., & Grood, E. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658080-00006 · Cited by 826
Anterior and posterior cruciate ligament reconstruction in rhesus monkeys.
Clancy, W. G., Narechania, R. G., Rosenberg, T. D., Gmeiner, J. G., Wisnefske, D. D., & Lange, T. A. (1981) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198163080-00008 · Cited by 703
NOYES, F. R., DELUCAS, J. L., & TORVIK, P. J. (1974) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197456020-00002 · Cited by 656
Fukubayashi, T., Torzilli, P. A., Sherman, M. F., & Warren, R. F. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264020-00018 · Cited by 554
Self-citationButler, D. L., Kay, M. D., & Stouffer, D. C. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90019-9 · Cited by 513
Kennedy, J., Hawkins, R., Willis, R., & Danylchuck, K. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658030-00009 · Cited by 472
Ligamentous Restraints to Anterior-Posterior Drawer in the Human Knee
Butler, D. L. (1980) · Medical Entomology and Zoology · Cited by 416
Woo, S. L.-Y. (1982) · Biorheology · doi:10.3233/bir-1982-19301 · Cited by 378
NOYES, F. R., BUTLER, D. L., PAULOS, L. E., & GROOD, E. S. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198301000-00014 · Cited by 275
Graft tension in anterior cruciate ligament reconstruction: An in vivo study in dogs
Yoshiya, S., Andrish, J. T., Manley, M. T., & Bauer, T. W. (1987) · The American Journal of Sports Medicine · doi:10.1177/036354658701500506 · Cited by 245
Experimental studies of acute anterior cruciate ligament injury and repair
Cabaud, H. E., Rodkey, W. G., & Feagin, J. A. (1979) · The American Journal of Sports Medicine · doi:10.1177/036354657900700105 · Cited by 157
Biomechanics of Cranial Cruciate Ligament Reconstruction in the Dog II. Mechanical Properties
Butler, D. L., Hulse, D. A., Kay, M. D., Grood, E. S., Shires, P. K., D'Ambrosia, R. D., & Shoji, H. (1983) · Veterinary Surgery · doi:10.1111/j.1532-950x.1983.tb00721.x · Cited by 134
Cross-sectional area measurements for tendon specimens: A comparison of several methods
Ellis, D. G. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90029-3 · Cited by 134
Cruciate ligament prosthesis: strength, creep, and fatigue properties
Grood, E. S., & Noyes, F. R. (1976) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-197658080-00007 · Cited by 132
Cruciate ligament prosthesis: strength, creep, and fatigue properties.
Grood, E., & Noyes, F. R. (1976) · PubMed · Cited by 108
Figgie, H. E., Bahniuk, E., Heiple, K. G., & Davy, D. T. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90139-9 · Cited by 48
Ryan, J. R., & Drompp, B. W. (1966) · Southern Medical Journal · doi:10.1097/00007611-196602000-00001 · Cited by 18
Cited by
HAMNER, D. L., BROWN, C. H., STEINER, M. E., HECKER, A. T., & HAYES, W. C. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199904000-00013 · Cited by 633
Knee biomechanics of the dynamic squat exercise
ESCAMILLA, R. F. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200101000-00020 · Cited by 570
“(11) have quantified the ultimate strength of the central third of the patellar tendon (a 15-mm bone-patellar tendon-bone composite) to be 4389 6”
BackgroundGraft Fixation in Cruciate Ligament Reconstruction
Brand, J., Weiler, A., Caborn, D. N. M., Brown, C. H., & Johnson, D. L. (2000) · The American Journal of Sports Medicine · doi:10.1177/03635465000280052501 · Cited by 436
Kousa, P., Järvinen, T. L. N., Vihavainen, M., Kannus, P., & Järvinen, M. (2003) · The American Journal of Sports Medicine · doi:10.1177/03635465030310020401 · Cited by 426
Aune, A. K., Holm, I., Risberg, M. A., Jensen, H. K., & Steen, H. (2001) · The American Journal of Sports Medicine · doi:10.1177/03635465010290060901 · Cited by 420
Metadata
- Authors
- Cooper, D. E., Deng, X. H., Burstein, A. L., & Warren, R. F.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 1993-11
- Volume
- 21
- Issue
- 6
- Pages
- 818-824
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2066262602
- Cited by
- 264
- References
- 21
- FWCI
- 7.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.