CoChat

Intra- and Interobserver Reproducibility of the Shoulder Laxity Examination

Levy, Andrew S., Lintner, Scott, Kenter, Keith, Speer, Kevin P. · 1999 · The American Journal of Sports Medicine
Cited by 98

The DOI matches its Crossref record.

Abstract

The present study evaluates the inter- and intraobserver reproducibility of clinical examination of glenohumeral laxity in the unanesthetized shoulder. Forty-three asymptomatic Division I collegiate athletes underwent bilateral shoulder laxity examination initially and again after 3 months. Translation of the humeral head on the glenoid fossa in the anterior, posterior, and inferior directions was graded by four physicians who were blinded to their own previous grading and that of the other examiners. Overall intraobserver reproducibility of examination was 46%. When grades 0 and 1 were equalized, overall intraobserver reproducibility improved to 74%. For both the equalized and non-equalized reproducibility values reported by all examiners, the kappa values for intraobserver correlation were less than 0.5, which suggests that correlations were not better than those achieved by chance alone. Overall interobserver reproducibility was 47%. When grades 0 and 1 were equalized, interobserver reproducibility improved to 78%. Kappa values were greater than 0.5 only in equalized posterior and inferior laxity. The data demonstrate that the laxity examination of the unanesthetized shoulder is not easily reproducible in either intra- or interobserver comparison. Equalization of grade 0 and grade 1 laxity improves both intra- and interobserver reproducibility. We recommend caution when determining diagnosis and treatment based on this examination.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/03635465990270040901

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 98

Metadata

Authors
Levy, A. S., Lintner, S., Kenter, K., & Speer, K. P.
Venue
The American Journal of Sports Medicine
Published
1999-07
Volume
27
Issue
4
Pages
460-463
ISSN
  • 0363-5465 (ISSN-L)
  • 1552-3365
OpenAlex
W2105968013
Cited by
98
References
0
FWCI
5.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intra- and Interobserver Reproducibility of the Shoulder Laxity Examination. https://app.cochat.ai/papers/10.1177/03635465990270040901
The paper
Levy, A. S., Lintner, S., Kenter, K., & Speer, K. P. (1999). Intra- and Interobserver Reproducibility of the Shoulder Laxity Examination. The American Journal of Sports Medicine. https://doi.org/10.1177/03635465990270040901

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.