Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 274

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Etiology of Implant Orthopedic Infections: A Survey on 1027 Clinical Isolates

Arciola, C.R., An, Y.H., Campoccia, D., Donati, M.E., Montanaro, L.·2005·The International Journal of Artificial Organs

Abstract

In spite of the recent achievements derived from modern protocols of prophylaxis, orthopedic surgical infections still remain unacceptably frequent, especially in light of the often devastating outcomes of septic complications. The spectrum and the prevalence of the bacteria most frequently involved in orthopedic infections are here explored, with particular reference to those infections associated to implant biomaterials, which were grouped based on device typology. During a 30 months period (from September 2000 to April 2003), 1027 microbial strains were consecutively isolated from 699 patients undergoing revision surgery at the Rizzoli Orthopedic Institute. 775 (75.5%) of all these microorganisms were identified as belonging to the Staphylococcus genus, 82 (8%) to the Enterobacteriaceae family, 75 (7.3%) to the Pseudomonas genus, 54 (5.3%) to the Enterococcus genus and 20 (1.9%) to the Streptococcus genus. While confirming the importance of staphylococci as the most diffuse cause of infection, our data indicate an unexpectedly high prevalence of S. epidermidis on infected hip and knee arthroprostheses, respectively of 42% and 44%. The spectrum of bacteria infecting either internal or external fracture fixation devices appears to differ from that of hip and knee arthroprostheses and more closely resembles that of infections non-associated to medical devices, being characterized by a relatively higher prevalence of Staphylococcus aureus (over 40%) and Pseudomonas aeruginosa. Enterobacteriaceae and members of the Streptococcus and Corynebacterium genera are frequently associated with implants in which surgical incisions were made near the perineum, determining a completely altered spectrum.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/039139880502801106

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 274

Metadata

Authors
Arciola, C. R., An, Y. H., Campoccia, D., Donati, M. E., & Montanaro, L.
Venue
The International Journal of Artificial Organs
Published
2005-11
Volume
28
Issue
11
Pages
1091-1100
ISSN
  • 0391-3988 (ISSN-L)
  • 1724-6040
OpenAlex
W2300643535
Cited by
274
References
1
FWCI
5.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Etiology of Implant Orthopedic Infections: A Survey on 1027 Clinical Isolates. https://app.cochat.ai/papers/10.1177/039139880502801106
The paper
Arciola, C. R., An, Y. H., Campoccia, D., Donati, M. E., & Montanaro, L. (2005). Etiology of Implant Orthopedic Infections: A Survey on 1027 Clinical Isolates. The International Journal of Artificial Organs. https://doi.org/10.1177/039139880502801106

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.