The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
The Tumescent Technique for Lipo-Suction Surgery
Abstract
The tumescent technique of lipo-suction is a modification of the wet technique. A large volume of very dilute epinephrine is infiltrated into a targeted fat compartment prior to lipo-suction, producing a swelling and firmness. This tumescence of fat permits an increased accuracy in lipo-suction and minimizes postsurgical irregularities or rippling of the skin. Epinephrine-induced vasoconstriction minimizes blood loss, bruising, and postoperative soreness. Safe, rapid infiltration of large volumes of solution is achieved using a closed sterile system featuring a newly designed blunt-tipped, 30-cm-long, 4.7-mm-diameter needle having a hollow handle that accommodates a 60-cc syringe. Attached to a liter bottle of anesthetic solution by an intravenous line, the needle is inserted via the same incision and deposits the solution along the same path as that intended for the lipo-suction cannula. Thus, the solution is infiltrated exactly where it is needed for hemostasis or local anesthesia. Used in conjunction with general anesthesia, the tumescent technique saves time in achieving maximal vasoconstriction of the targeted fat compartment. If dilute lidocaine (0.1%) is added to the solution, the technique permits lipo-suction of more than 2 liters of fat totally by local anesthesia. Twenty-six patients, having received a mean lidocaine dose of 1250 mg (18.4 mg/kg or 8.5 mg/kg/hr) infiltrated into subcutaneous fat, had a mean serum lidocaine level of less than 0.36 μg/ml 1 hour after completion of the infiltration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interrelationships of Hepatic Blood Flow, Cardiac Output, and Blood Levels of Lidocaine in Man
STENSON, R. E., CONSTANTINO, R. T., & HARRISON, D. C. (1971) · Circulation · doi:10.1161/01.cir.43.2.205 · Cited by 268
XYLOCAIN–A NEW LOCAL ANALGESIC
Gordh, T. (1949) · Anaesthesia · doi:10.1111/j.1365-2044.1949.tb05802.x · Cited by 95
The effect of low-dose epinephrine on the hematocrit drop following lipolysis
Hetter, G. P. (1984) · Aesthetic Plastic Surgery · doi:10.1007/bf01572780 · Cited by 67
Cited by
Lee, W.-S., Kim, H. J., Kim, K.-I., Kim, G. B., & Jin, W. (2019) · Stem Cells Translational Medicine · doi:10.1002/sctm.18-0122 · Cited by 497
Safety of Tumescent Liposuction in 15,336 Patients: National Survey Results
HANKE, W. C., BERNSTEIN, G., & BULLOCK, S. (1995) · Dermatologic Surgery · doi:10.1111/j.1524-4725.1995.tb00213.x · Cited by 269
Metadata
- Authors
- Klein, J. A.
- Venue
- The American Journal of Cosmetic Surgery
- Publisher
- SAGE Publications
- Published
- 1987-12
- Volume
- 4
- Issue
- 4
- Pages
- 263-267
- ISSN
- 0748-8068 (ISSN-L)
- 2374-7722
- OpenAlex
- W2570453866
- Cited by
- 784
- References
- 3
- FWCI
- 9.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Tumescent Technique for Lipo-Suction Surgery. https://app.cochat.ai/papers/10.1177/074880688700400403
- The paper
- Klein, J. A. (1987). The Tumescent Technique for Lipo-Suction Surgery. The American Journal of Cosmetic Surgery. https://doi.org/10.1177/074880688700400403
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.