Accuracy of Ultrasonographic Measurements of Inferior Vena Cava to Determine Fluid Responsiveness: A Systematic Review and Meta-Analysis
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Objective: Fluid responsiveness is the ability to increase the cardiac output in response to a fluid challenge. Only about 50% of patients receiving fluid resuscitation for acute circulatory failure increase their stroke volume, but the other 50% may worsen their outcome. Therefore, predicting fluid responsiveness is needed. In this purpose, in recent years, the assessment of the inferior vena cava (IVC) through ultrasound (US) has become very popular. The aim of our work was to systematically review all the previously published studies assessing the accuracy of the diameter of IVC or its respiratory variations measured through US in predicting fluid responsiveness. Data Sources: We searched in the MEDLINE (PubMed), Embase, Web of Science databases for all relevant articles from inception to September 2017. Study Selection: Included articles specifically addressed the accuracy of IVC diameter or its respiratory variations assessed by US in predicting the fluid responsiveness in critically ill ventilated or not, adult or pediatric patients. Data Extraction: We included 26 studies that investigated the role of the caval index (IVC collapsibility or distensibility) and 5 studies on IVC diameter. Data Synthesis: We conducted a meta-analysis for caval index with 20 studies: The pooled area under the curve, logarithmic diagnostic odds ratio, sensitivity, and specificity were 0.71 (95% confidence interval [CI]: 0.46-0.83), 2.02 (95% CI: 1.29-2.89), 0.71 (95% CI: 0.62-0.80), and 0.75 (95% CI: 0.64-0.85), respectively. Conclusion: An extreme heterogeneity of included studies was highlighted. Ultrasound evaluation of the diameter of the IVC and its respiratory variations does not seem to be a reliable method to predict fluid responsiveness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Rue, H., Martino, S., & Chopin, N. (2009) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.1467-9868.2008.00700.x · Cited by 5,279
Lindgren, F., Rue, H., & Lindström, J. (2011) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.1467-9868.2011.00777.x · Cited by 2,708 · cited 1×
“For construing SROC curve, we used a Bayesian inference method using integrated nested Laplace approximations for bivariate meta-analysis.(12-16) We implemented a hierarchical approach through the model of Rutter and Gatsonis.”
Method(2011) · Hepatogastroenterology · doi:10.5754/hge11125 · Cited by 2,450
A hierarchical regression approach to meta‐analysis of diagnostic test accuracy evaluations
Rutter, C. M., & Gatsonis, C. A. (2001) · Statistics in Medicine · doi:10.1002/sim.942 · Cited by 1,505 · cited 2×
“For construing SROC curve, we used a Bayesian inference method using integrated nested Laplace approximations for bivariate meta-analysis.12-16 We implemented a hierarchical approach through the model of Rutter and Gatsonis.17 We investigated heterogeneity through subanalyses of the setting in which the studies were c…”
MethodBayesian Spatial Modelling with R-INLA
Lindgren, F., & Rue, H. (2015) · Journal of Statistical Software · doi:10.18637/jss.v063.i19 · Cited by 1,188 · cited 1×
“For construing SROC curve, we used a Bayesian inference method using integrated nested Laplace approximations for bivariate meta-analysis.(12-16) We implemented a hierarchical approach through the model of Rutter and Gatsonis.”
MethodThe respiratory variation in inferior vena cava diameter as a guide to fluid therapy
Feissel, M., Michard, F., Faller, J.-P., & Teboul, J.-L. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2233-5 · Cited by 967
Barbier, C., Loubières, Y., Schmit, C., Hayon, J., Ricôme, J.-L., Jardin, F., & Vieillard-Baron, A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2259-8 · Cited by 940
Bayesian Computing with INLA: A Review
Rue, H., Riebler, A., Sørbye, S. H., Illian, J. B., Simpson, D. P., & Lindgren, F. K. (2017) · Annual Review of Statistics and Its Application · doi:10.1146/annurev-statistics-060116-054045 · Cited by 737 · cited 1×
“For construing SROC curve, we used a Bayesian inference method using integrated nested Laplace approximations for bivariate meta-analysis.(12-16) We implemented a hierarchical approach through the model of Rutter and Gatsonis.”
MethodBayesian computing with INLA: New features
Martins, T. G., Simpson, D., Lindgren, F., & Rue, H. (2013) · Computational Statistics & Data Analysis · doi:10.1016/j.csda.2013.04.014 · Cited by 604 · cited 1×
“For construing SROC curve, we used a Bayesian inference method using integrated nested Laplace approximations for bivariate meta-analysis.(12-16) We implemented a hierarchical approach through the model of Rutter and Gatsonis.”
Method
Cited by
European Resuscitation Council Guidelines 2021: Paediatric Life Support
Van de Voorde, P., Turner, N. M., Djakow, J., de Lucas, N., Martinez-Mejias, A., Biarent, D., Bingham, R., Brissaud, O., Hoffmann, F., Johannesdottir, G. B., et al. (2021) · Resuscitation · doi:10.1016/j.resuscitation.2021.02.015 · Cited by 448
Matsumoto, M., Tateishi, A., Kobayashi, H., & Hashiguchi, N. (2025) · PLOS One · doi:10.1371/journal.pone.0323367 · Cited by 5
Metadata
- Authors
- Orso, D., Paoli, I., Piani, T., Cilenti, F. L., Cristiani, L., & Guglielmo, N.
- Venue
- Journal of Intensive Care Medicine
- Publisher
- SAGE Publications
- Published
- 2018-01-17
- Volume
- 35
- Issue
- 4
- Pages
- 354-363
- ISSN
- 0885-0666 (ISSN-L)
- 1525-1489
- OpenAlex
- W2789822500
- Cited by
- 223
- References
- 44
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.