Autooxidative Degradation of Implanted Polyether Polyurethane Devices
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
While certain polyether polyurethanes have been shown to be biostable, undesirable interactions between polymer, the body environment and device can occur. For example, the corrosion products of metallic parts can cause relatively rapid autooxidation of polyether soft segments. This phenomenon was first demonstrated in our laboratories by immersing polyurethane test specimens in metal ion solutions of different oxidation potentials. Subsequently, the mechanism was reasonably duplicated by immersing Pellethane 2363-80A insulated cardiac pacing leads in 3%, 37°C hydrogen peroxide. In vivo studies after 1 year show that corrosion products from pure Co and Fe produce the most rapid degradation of the polyurethane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomaterial biocompatibility and the macrophage
Anderson, J. M., & Miller, K. M. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90060-7 · Cited by 403
Some aspects of macrophage behavior at the implant interface
Salthouse, T. N. (1984) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820180407 · Cited by 176
Cited by
Degradation and stabilization of polyurethane elastomers
Xie, F., Zhang, T., Bryant, P., Kurusingal, V., Colwell, J. M., & Laycock, B. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.12.003 · Cited by 722
Santerre, J. P., Woodhouse, K., Laroche, G., & Labow, R. S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.079 · Cited by 718
Macrophages, Foreign Body Giant Cells and Their Response to Implantable Biomaterials
Sheikh, Z., Brooks, P., Barzilay, O., Fine, N., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095269 · Cited by 701
“Studies have clearly shown that the use of antioxidants in polymeric biomaterial devices inhibits the oxidation process that occurs with the foreign body reaction [139,140].”
BackgroundMechanisms of polymer degradation in implantable devices
Ali, S. A. M., Zhong, S.-P., Doherty, P. J., & Williams, D. F. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90063-8 · Cited by 208
Tensile properties of orthodontic elastomeric chains
Eliades, T. (2004) · The European Journal of Orthodontics · doi:10.1093/ejo/26.2.157 · Cited by 73
“In this case, synergistic effects may arise from several factors such as loading, variations in temperature, solvents or pH fluctuations (Huget et al., 1990) leading to a reduced fatigue limit for a polymer specimen (Stokes et al., 1987).”
Influential
Metadata
- Authors
- Stokes, K., Coury, A., & Urbanski, P.
- Venue
- Journal of Biomaterials Applications
- Publisher
- SAGE Publications
- Published
- 1986-07
- Volume
- 1
- Issue
- 3
- Pages
- 411-448
- ISSN
- 0885-3282 (ISSN-L)
- 1530-8022
- OpenAlex
- W1968218735
- Cited by
- 106
- References
- 2
- FWCI
- 1.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.