Currently Practised Sterilization Methods-Some Inadvertent Consequences
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Currently used sterilization techniques such as ethylene oxide, y irradiation, and steam sterilization could introduce inadvertent consequences, especially in polymeric materials. These could have far-reaching effects on the biocompatibility of the materials. Some of these consequences are reviewed and a typical example of the effect of steam sterilization on the properties and biocompatibility of polyethylene terephthalate is discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Radiation chemistry of polymeric systems
CHAPIRO, A. (1962) · Interscience eBooks · Cited by 1,167
The Radiation Chemistry of Macromolecules
(1973) · Elsevier eBooks · doi:10.1016/c2013-0-10595-8 · Cited by 1,096
Radiation Chemistry of Polymeric Systems
Calkins, V. P. (1963) · Nuclear Science and Engineering · doi:10.13182/nse63-a26492 · Cited by 739
Ethrenberg, L., Hiesche, K. D., Osterman-Golkar, S., & Wennberg, I. (1974) · Mutation Research · doi:10.1016/0027-5107(74)90123-7 · Cited by 309
Spenlehauer, G., Vert, M., Benoit, J. P., & Boddaert, A. (1989) · Biomaterials · doi:10.1016/0142-9612(89)90063-x · Cited by 272
Late fiber deterioration in Dacron arterial grafts.
Berger, K., & Sauvage, L. R. (1981) · PubMed · Cited by 157
The effect of gamma irradiation on the enzymatic degradation of polyglycolic acid absorbable sutures
Chu, C. C., & Williams, D. F. (1983) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820170612 · Cited by 95
Sterilization of Medical Devices: A Review
Dempsey, D. J., & Thirucote, R. R. (1988) · Journal of Biomaterials Applications · doi:10.1177/088532828800300303 · Cited by 78
Quantitative assessment of the tissue response to implanted biomaterials
Vince, D. G., Hunt, J. A., & Williams, D. F. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90021-2 · Cited by 78
Determination of extractable methylene dianiline in thermoplastic polyurethanes by HPLC
Mazzu, A., & Smith, C. P. (1984) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820180810 · Cited by 74
Research works printed but not linked: 9
- 2. Szycher, M. 1991. "Biocompatible Materials and Devices," C. P. Sharma and M. Szycher, eds. Technomic Publishing Co. Inc., pp. 87-122.
- Clarke, C. R,, 1966, J. Surg., Australia and New Zealand, 36
- Ehlrenberg, L., 1974, Mutation Res., 24, 84
- Christensen, E. A., "Symposium on Radiosterilization of Medical Products Held by International Atomic Energy Agency at Budapest, Hungary."
- Takesawa S., 1987, Nephrol. Dial. Transplant., 1, 254
- Jayabalan, M., Proceedings of the Fifth Southern Biomedical Engineering Conference at Shreveport LA, 344
- Jayabalan, M., 1991, Biomed., 11, 7
- Berger, K., 1981, Ann. Surg., 193, 477
- Nair, P. D., "Studies on the Cytoxicity of IPNs,"
Cited by
Shape-memory polymers as a technology platform for biomedical applications
Lendlein, A., Behl, M., Hiebl, B., & Wischke, C. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.8 · Cited by 469
Kurtz, S. M., Gawel, H. A., & Patel, J. D. (2011) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-011-1872-4 · Cited by 468
Degradable Polymer Microspheres for Controlled Drug Delivery
Edlund, U., & Albertsson, A. C. (2002) · Advances in Polymer Science · doi:10.1007/3-540-45734-8_3 · Cited by 416
Bacterial inactivation by using near- and supercritical carbon dioxide
Dillow, A. K., Dehghani, F., Hrkach, J. S., Foster, N. R., & Langer, R. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10344 · Cited by 323
Non‐thermal bacterial inactivation with dense CO2
Spilimbergo, S., & Bertucco, A. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10783 · Cited by 246
Metadata
- Authors
- Nair, P. D.
- Affiliations
- Sree Chitra Thirunal Institute for Medical Sciences and Technology (IN)
- Corresponding author
- Nair, Prabha D.
- ORCID
- Nair, Prabha D.
- Venue
- Journal of Biomaterials Applications
- Publisher
- SAGE Publications
- Published
- 1995-10
- Volume
- 10
- Issue
- 2
- Pages
- 121-135
- ISSN
- 0885-3282 (ISSN-L)
- 1530-8022
- OpenAlex
- W1923399248
- Cited by
- 70
- References
- 34
- Citations by year
- 2024: 2 · 2023: 2 · 2021: 2 · 2020: 2 · 2019: 2 · 2018: 1 · 2017: 3 · 2016: 3 · 2015: 3 · 2014: 2 · 2013: 2 · 2012: 4
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Biomaterials Applications (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Immunology and Microbiology › Microbiology › Medical Device Sterilization and Disinfection
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- sterilization, ethylene oxide sterilization, gamma irradiation, autoclaving, polymeric biomaterials, biocompatibility, polyethylene terephthalate, radiation effects on polymers
- MeSH terms
- Biocompatible Materials, Ethylene Oxide, Gamma Rays, Humans, Polymers, Steam, Sterilization, Temperature
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Currently Practised Sterilization Methods-Some Inadvertent Consequences. https://app.cochat.ai/papers/10.1177/088532829501000203
- The paper
- Nair, P. D. (1995). Currently Practised Sterilization Methods-Some Inadvertent Consequences. Journal of Biomaterials Applications. https://doi.org/10.1177/088532829501000203
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.