Peritoneal Equilibration Test

Karl, Zbylut J. Twardowski, Khanna, O. Nolph Ramesh, Leonor, Barbara F. Prowant, Ryan, P., Moore, Harold L., Nielsen, Marc P.·1987·Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis

Abstract

Peritoneal transfer rates of urea, creatinine, glucose, protein potassium, and sodium as well as drain and residual volumes were measured during 103 equilibration tests performed in 18 diabetic and 68 nondiabetic patients. Equilibration test was performed over a 4-hour dwell exchange with 2 L of 2.5% Dianeal solution. Excellent reproducibility was seen after tests were standardized for length of preceding exchange, times of inflow and drainage, patient position, methods of obtaining and processing samples and laboratory assays. Diabetics did not have lower peritoneal solute transfers than nondiabetics. Wide variations were found in the study population. Measurements of creatinine, glucose and sodium transfer were particularly useful in predicting the patient's response to the standard CAPO. The patients with highaverage peritoneal solute transport did well on standard CAPO even after losing residual renal function. Patients with high peritoneal solute transfer rates were likely to have inadequate ultrafiltration on standard CAPO. These patients did much better on dialysis modalities with short dwell exchanges, i.e. nightly peritoneal dialysis (NPO) or daytime ambulatory peritoneal dialysis (OAPO). Patients with low average, and particularly low peritoneal transport rates were likely to develop symptoms and signs of inadequate dialysis as their residual renal function became negligible, particularly in individuals with high body surface area. Repeated tests were helpful in evaluating causes of insufficient ultrafiltration and/or inadequate dialysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/089686088700700306

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 1,059

Metadata

Authors
Karl, Z. J. T., Khanna, O. N. R., Leonor, B. F. P., Ryan, P., Moore, H. L., & Nielsen, M. P.
Venue
Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis
Published
1987-07
Volume
7
Issue
3
Pages
138-148
ISSN
  • 0896-8608 (ISSN-L)
  • 1718-4304
OpenAlex
W2097335942
Cited by
1,059
References
0
FWCI
8.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Peritoneal Equilibration Test. https://app.cochat.ai/papers/10.1177/089686088700700306
The paper
Karl, Z. J. T., Khanna, O. N. R., Leonor, B. F. P., Ryan, P., Moore, H. L., & Nielsen, M. P. (1987). Peritoneal Equilibration Test. Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis. https://doi.org/10.1177/089686088700700306

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.