The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fabrication of microchannels: A review
Abstract
Microchannels are primarily used in biomedical devices and microfluidic applications. Fabrication of microchannels has always been a tough task using conventional manufacturing technologies. Various types of materials are in use for fabricating microchannels in different types of applications including metals, polymers and ceramics. A number of methods are in use for fabricating different types of microchannels. These processes include both conventional and nonconventional fabrication techniques such as micromilling, lithography, embossing processes and laser ablation processing. During the recent years, some hybrid techniques have also been developed for fabrication of microchannels. This survey of various literatures reveals a broad spectrum of different processes used for fabricating microchannels. Currently, laser micromachining has been evolved as a potential technology for fabricating microchannels. Laser processing has been proved to be the most time efficient and clean. In this article, fabrication processes for creating microchannels have been reviewed with special emphasis on laser micromachining. This article mostly addresses the fabrication techniques for creating surface microchannels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Finer features for functional microdevices
Kawata, S., Sun, H.-B., Tanaka, T., & Takada, K. (2001) · Nature · doi:10.1038/35089130 · Cited by 2,871
Cited by
A review of the state-of-the-art in electronic cooling
Zhang, Z., Wang, X., & Yan, Y. (2021) · e-Prime - Advances in Electrical Engineering, Electronics and Energy · doi:10.1016/j.prime.2021.100009 · Cited by 310
Dong, G., Chen, B., Liu, B., Hounjet, L. J., Cao, Y., Stoyanov, S. R., Yang, M., & Zhang, B. (2022) · Water Research · doi:10.1016/j.watres.2022.118047 · Cited by 303
Xu, X., Cui, L., Zhang, Y., & Gu, J. (2026) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2025.11.023 · Cited by 13
“Microfluidic mixing, currently the predominant method for mRNA-LNP preparation, ensures superior reproducibility and robust process control 40,41 .”
Metadata
- Authors
- Prakash, S., & Kumar, S.
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture
- Publisher
- SAGE Publications
- Published
- 2014-06-17
- Volume
- 229
- Issue
- 8
- Pages
- 1273-1288
- ISSN
- 0954-4054 (ISSN-L)
- 2041-2975
- OpenAlex
- W2094983886
- Cited by
- 176
- References
- 1
- FWCI
- 4.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fabrication of microchannels: A review. https://app.cochat.ai/papers/10.1177/0954405414535581
- The paper
- Prakash, S., & Kumar, S. (2015). Fabrication of microchannels: A review. Proceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture. https://doi.org/10.1177/0954405414535581
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.