Biocompatibility of Poly (DL-Lactide-co-Glycolide) Microspheres Implanted into the Brain
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The delivery of therapeutic molecules to the brain has been limited in part due to the presence of the blood–brain barrier. One potential solution is the implantation of biodegradable polymers with sustained release of drugs. Poly (DL-lactide-co-glycolide) (PLG) is a bioerodible polymer with a long and successful history of use as a suture material. More recently, PLG has been investigated for localized and sustained delivery of molecules into both peripheral sites and the brain. Despite its well-defined safety profile for parenteral applications, little information exists concerning the safety of PLG when implanted into the brain. To further characterize the biocompatibility of PLG in the brain, we examined the gliotic response following implants of PLG into the brains of rats. As a control, each animal received an injection of the suspension medium into the contralateral hemisphere. Following implantation, PLG was well tolerated. GFAP-positive astrocytes were observed throughout the cerebral cortex and striatum on both the implanted and control sides, with the reaction being greatest within the heavily myelinated fiber tracts of the corpus callosum. Quantitative analyses revealed that this reaction occurred within 1 h postsurgery, reached its peak at 1 week following surgery, and then decreased markedly by 1 month postsurgery. A minimal gliotic reaction was still present 1 year postsurgery but was localized to the needle tract. No differences in GFAP reactivity were seen between the polymer-implanted and control sides at any time point. Histological analysis determined that the majority of the PLG disappeared between 1 and 4 weeks. A set of parallel studies in which PLG samples were retrieved from the brain at various time points corroborated these findings and determined that the majority of PLG degraded within 2 weeks following implantation. Together, these results demonstrate that PLG is well tolerated following implantation into the CNS and that the astrocytic response to PLG is largely a consequence of the mechanical trauma that occurs during surgery. The biocompatibility of PLG implanted into the CNS provides further support for its use in a wide range of new therapeutic applications for sustained and localized drug delivery to the brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CNS Drug Design Based on Principles of Blood‐Brain Barrier Transport
Pardridge, W. M. (1998) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.1998.70051781.x · Cited by 460
Cited by
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
“…is complete, and perhaps as long as the material remains in contact with brain tissue (Stensaas and Stensaas, 1976, 1978; Winn t al., 1989; Edell et al., 1992; Menei et al., 1994; Kunkler and Kraig, 1997; Mofid et al., 1997; Emerich et al., 1999; Mokry et al., 2000; Szarowski et al., 2003).”
BackgroundTraumatic Brain Injuries: Pathophysiology and Potential Therapeutic Targets
Ng, S. Y., & Lee, A. Y. W. (2019) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2019.00528 · Cited by 852
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
In vivo studies of polypyrrole/peptide coated neural probes
Cui, X. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00415-5 · Cited by 505
Drug transport to brain with targeted nanoparticles
Olivier, J.-C. (2005) · NeuroRX · doi:10.1602/neurorx.2.1.108 · Cited by 444
Biocompatibility of implantable synthetic polymeric drug carriers: focus on brain biocompatibility
Fournier, E., Passirani, C., Montero-Menei, C. N., & Benoit, J. P. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00161-3 · Cited by 353
Peptide drug modifications to enhance bioavailability and blood-brain barrier permeability
Witt, K. A., Gillespie, T. J., Huber, J. D., Egleton, R. D., & Davis, T. P. (2001) · Peptides · doi:10.1016/s0196-9781(01)00537-x · Cited by 227
Biomaterials for the central nervous system
Zhong, Y., & Bellamkonda, R. V. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0071 · Cited by 221
Effective GDNF brain delivery using microspheres—A promising strategy for Parkinson's disease
Garbayo, E., Montero-Menei, C. N., Ansorena, E., Lanciego, J. L., Aymerich, M. S., & Blanco-Prieto, M. J. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.12.010 · Cited by 150
“observed around the needle tract (Figure 6A) [14, 16, 24].”
Nanoparticles as Blood–Brain Barrier Permeable CNS Targeted Drug Delivery Systems
Grabrucker, A. M., Chhabra, R., Belletti, D., Forni, F., Vandelli, M. A., Ruozi, B., & Tosi, G. (2013) · Topics in Medicinal Chemistry · doi:10.1007/7355_2013_22 · Cited by 53
Biodegradable microparticles for strictly regulating the release of neurotrophic factors
Gujral, C., Minagawa, Y., Fujimoto, K., Kitano, H., & Nakaji-Hirabayashi, T. (2013) · Journal of Controlled Release · doi:10.1016/j.jconrel.2013.03.031 · Cited by 21
Metadata
- Authors
- Emerich, D. F., Tracy, M. A., Ward, K. L., Figueiredo, M., Qian, R., Henschel, C., & Bartus, R. T.
- Venue
- Cell Transplantation
- Publisher
- SAGE Publications
- Published
- 1999-01
- Volume
- 8
- Issue
- 1
- Pages
- 47-58
- ISSN
- 0963-6897 (ISSN-L)
- 1555-3892
- OpenAlex
- W2426854287
- Cited by
- 87
- References
- 1
- FWCI
- 4.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.