The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Mode and Transducer Selection for Long Range Lamb Wave Inspection
Abstract
Lamb waves can propagate many metres along plate and shell structures, and so have great potential in ‘smart structure’ applications where it is important for a transducer to interrogate a significant area of the surrounding structure. However, there are many different types of Lamb wave and in order to obtain simple signals that can be reliably interpreted, it is important to excite a single mode in a well controlled direction. The choice of which Lamb wave mode to use in a particular application depends on numerous factors, including the resolution required, the type of defects or damage to be detected, the attenuation and the available transduction options. This paper sets out a rational procedure for identifying suitable Lamb wave modes and operating frequencies for a particular inspection task. It is shown that the properties of the system to be inspected determine which mode and frequencies can be used, and that this then dictates the type of transducer required. A procedure for evaluating the performance of Lamb wave transducers is also demonstrated. As an illustrative example, it is shown that the well known angle incidence transduction technique is not generally suitable in applications where the structure to be inspected is liquid loaded. In such cases it is necessary to consider alternative transduction options such as electromagnetic acoustic transducers (EMATs) or shear piezoelectric devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The interaction of Lamb waves with defects
Alleyne, D. N., & Cawley, P. (1992) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.143172 · Cited by 997
Self-citationRayleigh and Lamb Waves : Physical Theory and Applications
Viktorov, I. A. (2013) · Cited by 954
The excitation of Lamb waves in pipes using dry-coupled piezoelectric transducers
Alleyne, D. N., & Cawley, P. (1996) · Journal of Nondestructive Evaluation · doi:10.1007/bf00733822 · Cited by 227
Self-citation
Cited by
Ultrasonic Guided Waves in Solid Media
Rose, J. L. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9781107273610 · Cited by 1,496
Guided wave based structural health monitoring: A review
Mitra, M., & Gopalakrishnan, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/5/053001 · Cited by 1,045
Miao, H., & Li, F. (2021) · Ultrasonics · doi:10.1016/j.ultras.2021.106355 · Cited by 268
Structural Health Monitoring Damage Detection Systems for Aerospace
(2021) · Springer Aerospace Technology · doi:10.1007/978-3-030-72192-3 · Cited by 92
Metadata
- Authors
- Wilcox, P. D., Lowe, M. J. S., & Cawley, P.
- Venue
- Journal of Intelligent Materials Systems and Structures
- Publisher
- SAGE Publications
- Published
- 2001-08-01
- Volume
- 12
- Issue
- 8
- Pages
- 553-565
- ISSN
- 1045-389X (ISSN-L)
- 0000-0000
- OpenAlex
- W2155895928
- Cited by
- 265
- References
- 3
- FWCI
- 4.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mode and Transducer Selection for Long Range Lamb Wave Inspection. https://app.cochat.ai/papers/10.1177/10453890122145348
- The paper
- Wilcox, P. D., Lowe, M. J. S., & Cawley, P. (2001). Mode and Transducer Selection for Long Range Lamb Wave Inspection. Journal of Intelligent Materials Systems and Structures. https://doi.org/10.1177/10453890122145348
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.