Tuned Lamb Wave Excitation and Detection with Piezoelectric Wafer Active Sensors for Structural Health Monitoring
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The capability of embedded piezoelectric wafer active sensors (PWAS) to excite and detect tuned Lamb waves for structural health monitoring is explored. First, a brief review of Lamb waves theory is presented. Second, the PWAS operating principles and their structural coupling through a thin adhesive layer are analyzed. Then, a model of the Lamb waves tuning mechanism with PWAS transducers is described. The model uses the space domain Fourier transform. The analysis is performed in the wavenumber space. The inverse Fourier transform is used to return into the physical space. The integrals are evaluated with the residues theorem. A general solution is obtained for a generic expression of the interface shear stress distribution. The general solution is reduced to a closed-form expression for the case of ideal bonding which admits a closed-form Fourier transform of the interfacial shear stress. It is shown that the strain wave response varies like sin a, whereas the displacement response varies like sinc a. Maximum coupling is achieved when the PWAS length equals the half wavelength of a particular Lamb wave mode. Since Lamb wave modes wavelengths vary with frequency, the tuning of certain modes at certain frequencies can thus be achieved. Tuning curves are derived and verified against experimental results. A particular S 0 mode ‘sweet spot’ is found at 300 kHz for a 7-mm PWAS attached to a 1.6-mm aluminum plate. Crack detection via the pulse echo technique using the phased array principle and tuned S 0 mode Lamb waves is demonstrated as an effective structural health monitoring method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Téllez, A. F. (2006) · conference · Cited by 5,352
Use of piezoelectric actuators as elements of intelligent structures
Crawley, E. F., & de Luis, J. (1987) · AIAA Journal · doi:10.2514/3.9792 · Cited by 2,602
Review of Progress in Quantitative Nondestructive Evaluation: Volume 15A
(1996) · Springer eBooks · doi:10.1007/978-1-4613-0383-1 · Cited by 1,963
Journal of intelligent material systems and structures
(1990) · Materials & Design (1980-2015) · doi:10.1016/0261-3069(90)90079-y · Cited by 691
A Baseline and Vision of Ultrasonic Guided Wave Inspection Potential
Rose, J. L. (2002) · Journal of Pressure Vessel Technology · doi:10.1115/1.1491272 · Cited by 611
The Potential of Guided Waves for Monitoring Large Areas of Metallic Aircraft Fuselage Structure
Dalton, R. P., Cawley, P., & Lowe, M. J. S. (2001) · Journal of Nondestructive Evaluation · doi:10.1023/a:1010601829968 · Cited by 249
Lin, X., & Yuan, F. G. (2001) · Smart Materials and Structures · doi:10.1088/0964-1726/10/5/307 · Cited by 178
Humar, J. L., & Amin, M. S. (2001) · Elsevier eBooks · doi:10.1016/b978-008043948-8/50132-6 · Cited by 66
Cited by
Ultrasonic Guided Waves in Solid Media
Rose, J. L. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9781107273610 · Cited by 1,496
Guided wave based structural health monitoring: A review
Mitra, M., & Gopalakrishnan, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/5/053001 · Cited by 1,045
Zhao, X., Gao, H., Zhang, G., Ayhan, B., Yan, F., Kwan, C., & Rose, J. L. (2007) · Smart Materials and Structures · doi:10.1088/0964-1726/16/4/032 · Cited by 736
Bonded repair of composite aircraft structures: A review of scientific challenges and opportunities
Katnam, K. B., Da Silva, L. F. M., & Young, T. M. (2013) · Progress in Aerospace Sciences · doi:10.1016/j.paerosci.2013.03.003 · Cited by 610
Malekloo, A., Ozer, E., AlHamaydeh, M., & Girolami, M. (2022) · Structural Health Monitoring · doi:10.1177/14759217211036880 · Cited by 607
An overview of lead-free piezoelectric materials and devices
Wei, H., Wang, H., Xia, Y., Cui, D., Shi, Y., Dong, M., Liu, C., Ding, T., Zhang, J., Ma, Y., et al. (2018) · Journal of Materials Chemistry C · doi:10.1039/c8tc04515a · Cited by 393
Optimization of sensor placement for structural health monitoring: a review
Ostachowicz, W., Soman, R., & Malinowski, P. (2019) · Structural Health Monitoring · doi:10.1177/1475921719825601 · Cited by 388
A Critical Review on Structural Health Monitoring: Definitions, Methods, and Perspectives
Gharehbaghi, V. R., Noroozinejad Farsangi, E., Noori, M., Yang, T. Y., Li, S., Nguyen, A., Málaga-Chuquitaype, C., Gardoni, P., & Mirjalili, S. (2022) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-021-09665-9 · Cited by 330
In situ 2-D piezoelectric wafer active sensors arrays for guided wave damage detection
Yu, L., & Giurgiutiu, V. (2008) · Ultrasonics · doi:10.1016/j.ultras.2007.10.008 · Cited by 315
Self-citationGuided wave signal processing and image fusion for in situ damage localization in plates
Michaels, J. E., & Michaels, T. E. (2007) · Wave Motion · doi:10.1016/j.wavemoti.2007.02.008 · Cited by 298
Gorgin, R., Luo, Y., & Wu, Z. (2020) · Ultrasonics · doi:10.1016/j.ultras.2020.106114 · Cited by 285
Miao, H., & Li, F. (2021) · Ultrasonics · doi:10.1016/j.ultras.2021.106355 · Cited by 268
Xu, B., & Giurgiutiu, V. (2007) · Journal of Nondestructive Evaluation · doi:10.1007/s10921-007-0027-8 · Cited by 243
“In practice, the single mode Lamb wave can be obtained by using the PWAS Lamb wave frequency tuning technique [19].”
BackgroundMethodInfluentialSelf-citationMachine learning for structural health monitoring: challenges and opportunities
Yuan, F.-G., Zargar, S. A., Chen, Q., & Wang, S. (2020) · Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems 2020 · doi:10.1117/12.2561610 · Cited by 207
“, a network of piezoelectric (PZT) sensor arrays) [106] or fully non-contact means (e.”
BackgroundTemperature effects in ultrasonic Lamb wave structural health monitoring systems
Lanza di Scalea, F., & Salamone, S. (2008) · The Journal of the Acoustical Society of America · doi:10.1121/1.2932071 · Cited by 203
Advanced design for lightweight structures: Review and prospects
Braga, D. F. O., Tavares, S. M. O., da Silva, L. F. M., Moreira, P. M. G. P., & de Castro, P. M. S. T. (2014) · Progress in Aerospace Sciences · doi:10.1016/j.paerosci.2014.03.003 · Cited by 174
Damage localisation in plate-like structures based on PZT sensors
Ostachowicz, W., Kudela, P., Malinowski, P., & Wandowski, T. (2009) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2008.10.011 · Cited by 159
Roy, S., Lonkar, K., Janapati, V., & Chang, F.-K. (2014) · Structural Health Monitoring · doi:10.1177/1475921714522846 · Cited by 126
“The observed linear relationship is also evident from the sensor voltage expression as shown in equation (1).”
BackgroundMethodStructural Health Monitoring Damage Detection Systems for Aerospace
(2021) · Springer Aerospace Technology · doi:10.1007/978-3-030-72192-3 · Cited by 92
Amer, A., & Kopsaftopoulos, F. P. (2022) · Structural Health Monitoring · doi:10.1177/14759217211024527 · Cited by 13
Liu, Y., Yekani Fard, M., & Chattopadhyay, A. (2012) · 53rd AIAA/ASME/ASCE/AHS/ASC Structures, Structural Dynamics and Materials Conference 20th AIAA/ASME/AHS Adaptive Structures Conference 14th AIAA · doi:10.2514/6.2012-1787 · Cited by 2
“More details of guided waves propagation method can be found in the literature [5-8].”
Background
Metadata
- Authors
- Giurgiutiu, V.
- Venue
- Journal of Intelligent Material Systems and Structures
- Publisher
- SAGE Publications
- Published
- 2005-04
- Volume
- 16
- Issue
- 4
- Pages
- 291-305
- ISSN
- 1045-389X (ISSN-L)
- 1530-8138
- OpenAlex
- W2030262987
- Cited by
- 942
- References
- 8
- FWCI
- 43.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.