Practical Implementation of Optical Fiber Sensors in Civil Structural Health Monitoring

Ansari, Farhad · 2007 · Journal of Intelligent Material Systems and Structures
Cited by 199

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Implementation of successful civil structural health monitoring strategies requires selection and placement of sensors suitable for measurement of key parameters that influence the performance and health of the structural system. Optical fiber sensors have been successfully implemented in aeronautics, mechanical systems, and medical applications. Civil structures pose further challenges in monitoring mainly due to their large dimensions, diversity as well as heterogeneity of materials involved, and hostile construction environment. This article provides a summary of basic principles pertaining to practical health monitoring of civil engineering structures with optical fiber sensors. The issues discussed include basic sensor principles, strain transfer mechanism, sensor packaging, sensor placement in construction environment, and reliability and survivability of the sensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1045389x06075760

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Coherence multiplexing of fiber-optic interferometric sensors

    Brooks, J., Wentworth, R., Youngquist, R., Tur, M., Kim, B., & Shaw, H. (1985) · Journal of Lightwave Technology · doi:10.1109/jlt.1985.1074308 · Cited by 228 · cited 2×

    “…technologies have become available for serial or parallel multiplexing of sensors using Brillouin scattering, Bragg gratings, and interferometry (Brooks et al., 1985; McGarrity et al., 1995; Davis et al., 1997; Murray and Krishnaswamy, 2001; Zhao and Ansari, 2001; Wu and Xu, 2002; Zeng et al.,…”
    Method
  • Sensing Issues in Civil Structural Health Monitoring

    Ansari, F. (2005) · Springer eBooks · doi:10.1007/1-4020-3661-2 · Cited by 177 · cited 1×

    “Calibration and referencing for permanently integrated sensors This list is not exhaustive, but it serves to illustrate some of the characteristic issues that need to be addressed to assure success in a typicalCSHMprogram (Ansari, 2005).”
    BackgroundSelf-citation

Cited by

See all 199

Metadata

Authors
Ansari, F.
Venue
Journal of Intelligent Material Systems and Structures
Published
2007-08
Volume
18
Issue
8
Pages
879-889
ISSN
  • 1045-389X (ISSN-L)
  • 1530-8138
OpenAlex
W2046149088
Cited by
199
References
2
FWCI
4.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.