The DOI matches its Crossref record.
Tailoring Piezoresistive Sensitivity of Multilayer Carbon Nanotube Composite Strain Sensors
Open accessAbstract
In recent years, carbon nanotubes have been utilized for a variety of applications, including nanoelectronics and various types of sensors. In particular, researchers have sought to take advantage of the superior electrical properties of carbon nanotubes for fabricating novel strain sensors. This article presents a single-walled carbon nanotube (SWNT)-polyelectrolyte (PE) composite thin film strain sensor fabricated with a layer-by-layer (LbL) process. Optimization of bulk SWNT-PE strain sensor properties is achieved by varying various LbL fabrication parameters, followed by characterization of strain-sensing electromechanical responses. A resistor and capacitor (RC)-circuit model is proposed and validated with electrical impedance spectroscopy to fit experimental results and to identify equivalent circuit element parameters sensitive to strain. Experimental results suggest consistent trends between SWNT and PE concentrations to strain sensor sensitivities. Simply by adjusting the weight fraction of SWNT solutions and film thickness, strain sensitivities between 0.1 and 1.8 have been achieved. While SWNT-PE strain sensitivity is lower than some metal-foil strain gauges ($2), the LbL method allows for precise tailoring of the properties (i.e., strain sensitivity, resistivity, among others) of a high-capacity (±10,000 μm m-1) homogeneous multilayer strain sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Investigation on sensitivity of a polymer/carbon nanotube composite strain sensor
Hu, N., Karube, Y., Arai, M., Watanabe, T., Yan, C., Li, Y., Liu, Y., & Fukunaga, H. (2010) · Carbon · doi:10.1016/j.carbon.2009.10.012 · Cited by 705
Highly sensitive and flexible strain sensors based on vertical zinc oxide nanowire arrays
Zhang, W., Zhu, R., Nguyen, V., & Yang, R. (2014) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2013.11.004 · Cited by 111
Hassan, H., & Tallman, T. N. (2020) · Structural Health Monitoring · doi:10.1177/1475921719863062 · Cited by 55
Metadata
- Authors
- Loh, K. J., Lynch, J. P., Shim, B. S., & Kotov, N. A.
- Venue
- Journal of Intelligent Material Systems and Structures
- Publisher
- SAGE Publications
- Published
- 2007-10-17
- Volume
- 19
- Issue
- 7
- Pages
- 747-764
- ISSN
- 1045-389X (ISSN-L)
- 1530-8138
- OpenAlex
- W2127654454
- Cited by
- 180
- References
- 0
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tailoring Piezoresistive Sensitivity of Multilayer Carbon Nanotube Composite Strain Sensors. https://app.cochat.ai/papers/10.1177/1045389x07079872
- The paper
- Loh, K. J., Lynch, J. P., Shim, B. S., & Kotov, N. A. (2008). Tailoring Piezoresistive Sensitivity of Multilayer Carbon Nanotube Composite Strain Sensors. Journal of Intelligent Material Systems and Structures. https://doi.org/10.1177/1045389x07079872
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.