The DOI matches its Crossref record; 23 of the 24 references it cites were found in a registry or an index.
Effects of Elevated Temperature on Guided-wave Structural Health Monitoring
Abstract
Elevated temperatures can cause significant changes in guided-wave (GW) propagation and transduction for structural health monitoring (SHM). This work focuses on GW SHM using surface-bonded piezoelectric wafer transducers in metallic plates for the temperature range encountered in internal spacecraft structures (20—150°C). First, studies done to determine a suitable bonding agent are documented. This is then used in controlled experiments to examine changes in GW propagation and transduction using PZT-5A piezoelectric wafers under quasi-statically varying temperature (also from 20 to 150°C). Modeling efforts to explain the experimentally observed increase in time-of-flight and change in sensor response peak-to-peak magnitude with increasing temperature are detailed. Finally, these results are used in detection and location of mild and moderate damage using the pulse-echo GW testing approach within the temperature range.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The findings of several studies have been reported on the influences of temperature changes on signal measurements from SHM systems [123,124].”
From Effects of Environmental and Operational Conditions on Structural Health Monitoring and Non-Destructive Testing: A Systematic Review (2023) · cites this paper as [124]
Citations
Cites
Review of Guided-wave Structural Health Monitoring
Raghavan, A., & Cesnik, C. E. S. (2007) · The Shock and Vibration Digest · doi:10.1177/0583102406075428 · Cited by 990
Lu, Y., & Michaels, J. E. (2005) · Ultrasonics · doi:10.1016/j.ultras.2005.05.001 · Cited by 396
The temperature stability of guided wave structural health monitoring systems
Konstantinidis, G., Drinkwater, B. W., & Wilcox, P. D. (2006) · Smart Materials and Structures · doi:10.1088/0964-1726/15/4/010 · Cited by 270
Raghavan, A., & Cesnik, C. E. S. (2005) · Smart Materials and Structures · doi:10.1088/0964-1726/14/6/037 · Cited by 266
Measurement Science and Technology 2024
Yacoot, A. (2024) · Measurement Science and Technology · doi:10.1088/1361-6501/ad7b68 · Cited by 208
Raghavan, A., & Cesnik, C. E. S. (2007) · Smart Materials and Structures · doi:10.1088/0964-1726/16/2/014 · Cited by 138
Optical fiber sensors for spacecraft applications
Friebele, E. J., Askins, C. G., Bosse, A., Kersey, A. D., Patrick, H. J., Pogue, W. R., Putnam, M. A., Simon, W., Tasker, F., Vincent, W. S., et al. (1999) · Smart Materials and Structures · doi:10.1088/0964-1726/8/6/310 · Cited by 122
Piezoelectric Materials at Elevated Temperature
Schulz, M. J., Sundaresan, M. J., Mcmichael, J., Clayton, D., Sadler, R. L., & Nagel, B. (2003) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x03038577 · Cited by 102
David, E. M., Martin, J. C. J., & Max, L. B. (2000) · NASA Technical Reports Server (NASA) · Cited by 101
Evolution of surface roughness of some metallic materials in cavitation erosion
Chiu, K. Y., Cheng, F. T., & Man, H. C. (2005) · Ultrasonics · doi:10.1016/j.ultras.2005.03.009 · Cited by 75
Chaudhry, Z. A., & Rogers, C. A. (1994) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x9400500307 · Cited by 71
Environmental Effects on Lamb Wave Responses from Piezoceramic Sensors
Lee, B. C., Manson, G., & Staszewski, W. J. (2003) · Materials science forum · doi:10.4028/www.scientific.net/msf.440-441.195 · Cited by 64
TEMPERATURE-DEPENDENT THERMOELASTIC PROPERTIES FOR MACRO FIBER COMPOSITE ACTUATORS
Williams, R. B., Inman, D. J., & Wilkie, W. K. (2004) · Journal of Thermal Stresses · doi:10.1080/01495730490498386 · Cited by 35
Raghavan, A., & Cesnik, C. E. S. (2007) · Journal of vibration and acoustics · doi:10.1115/1.2748776 · Cited by 35
Monitoring the integrity of filament-wound structures using built-in sensor networks
Lin, M. W., Kumar, A., Qing, X., Beard, S. J., Russell, S. S., Walker, J. L., & DeLay, T. K. (2003) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.483877 · Cited by 23
Durability Assessment of Lamb Wave-Based Structural Health Monitoring Nodes
Chambers, J. T., Wardle, B. L., & Kessler, S. S. (2006) · AIAA/ASME/ASCE/AHS/ASC Structures, Structural Dynamics, and Materials Conference (SDM) · doi:10.2514/6.2006-2263 · Cited by 23
Belikov, V. V., Vabishchevich, N. P., Vabishchevich, P. N., Katishkov, U. V., & Mosunova, N. A. (2015) · Mathematical Models and Computer Simulations · doi:10.1134/s2070048215020027 · Cited by 21
BENDING-TORSION FLUTTER OF LINEAR VISCOELASTIC WINGS INCLUDING STRUCTURAL DAMPING
Hilton, H. H., & Vail, C. F. (1993) · AIAA/ASME/ASCE/AHS/ASC Structures, Structural Dynamics, and Materials Conference (SDM) · doi:10.2514/6.1993-1475 · Cited by 17
Raghavan, A., & Cesnik, C. E. S. (2007) · AIAA/ASME/ASCE/AHS/ASC Structures, Structural Dynamics, and Materials Conference (SDM) · doi:10.2514/6.2007-1725 · Cited by 16
Health Management and Automation for Future Space Systems
Garcia-Galan, C., Crocker, A. R., & Aaseng, G. B. (2005) · doi:10.2514/6.2005-6803 · Cited by 13
Detection of fastener failure in a thermal protection system
Derriso, M. M., Olson, S. E., Braisted, W. R., DeSimio, M. P., Rosenstengel, J., & Brown, K. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.562967 · Cited by 5
Design of a built-in health monitoring system for bolted thermal protection panels
Yang, J., Chang, F., & Derriso, M. M. (2003) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.508340 · Cited by 4
Structural sensor testing for space vehicle applications
Huang, J., Rose, J. M., Gordon, J., & Boucher, R. (2005) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.607302 · Cited by 2
Research works printed but not linked: 15
- Bacry, E., 2007, LastWave 2.0 software
- Berlincourt, D., 2007, Morgan Electroceramics Technical Publication
- Blaise, E., Proceedings of the 3rd International Workshop on Structural Health Monitoring
- Carlos, G.-C., Proceedings of the AIAA Space 2005 Conference and Exposition
- Chambers, J., Proc. 47th AIAA/ASME/ASCE/AHS/ASC Structures, Structural Dynamics, and Materials Conference
- Epoxies Etc., 2006, 10-3004 Adhesive Technical Datasheet
- Epoxy Technology, 2006, Epoxies 301 and 353ND Technical Datasheets
- Hilton, H.H., Proc. AIAA/ASME Structures, Structural Dynamics and Materials Conference
- Larson, W.J., 1995, Space System Design and Analysis
- Lord, J.D., 2000, ``Elevated Temperature Modulus Measurements using the Impulse Excitation Technique,''
- Raghavan, A., 2005, ``Lamb Wave Methods in Structural Health Monitoring,''
- Raghavan, A., 2007, Special Issue on Damage Detection and Structural Health Monitoring, 129, 739
- Raghavan, A., Presented at the 15th AIAA/ASME/ASC Adaptive Structures Conference
- Stanley, D., 2005, Exploration Systems Architecture Study Final Report
- U.S. Munitions Board Aircraft Committee, 1955, ``Strength of Metal Aircraft Elements,'' ANC-5 Bulletin
Cited by
Sorted by citations
Efficient temperature compensation strategies for guided wave structural health monitoring
Croxford, A. J., Moll, J., Wilcox, P. D., & Michaels, J. E. (2009) · Ultrasonics · doi:10.1016/j.ultras.2009.11.002 · Cited by 376
Gorgin, R., Luo, Y., & Wu, Z. (2020) · Ultrasonics · doi:10.1016/j.ultras.2020.106114 · Cited by 286
Ladpli, P., Kopsaftopoulos, F., & Chang, F.-K. (2018) · Journal of Power Sources · doi:10.1016/j.jpowsour.2018.02.056 · Cited by 214
Abbas, M., & Shafiee, M. (2018) · Sensors · doi:10.3390/s18113958 · Cited by 184
Lopez, I., & Sarigul‐Klijn, N. (2010) · Progress in Aerospace Sciences · doi:10.1016/j.paerosci.2010.03.003 · Cited by 157
Metadata
- Authors
- Raghavan, A., & Cesnik, C. E. S.
- Affiliations
- University of Michigan (US)
- Corresponding author
- Cesnik, Carlos E.S.
- Venue
- Journal of Intelligent Material Systems and Structures
- Publisher
- SAGE Publications
- Published
- 2008-05-20
- Volume
- 19
- Issue
- 12
- Pages
- 1383-1398
- ISSN
- 1045-389X (ISSN-L)
- 1530-8138
- OpenAlex
- W1988217985
- Cited by
- 138
- References
- 24
- Citations by year
- 2026: 7 · 2025: 4 · 2024: 9 · 2023: 6 · 2022: 11 · 2021: 6 · 2020: 12 · 2019: 7 · 2018: 9 · 2017: 7 · 2016: 10 · 2015: 8 · 2014: 13 · 2013: 6 · 2012: 9
- FWCI
- 7.48
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Intelligent Material Systems and Structures (publishedVersion)
- Funders
- U.S. Department of Defense
- National Aeronautics and Space Administration
- Topics
- Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
- Physical Sciences › Engineering › Civil and Structural Engineering › Structural Health Monitoring Techniques
- Physical Sciences › Engineering › Mechanical Engineering › Non-Destructive Testing Techniques
- Keywords
- guided wave structural health monitoring, high temperature effects, PZT-5A, metal plates, time-of-flight, damage detection, damage localization, pulse-echo testing, spacecraft structures
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review