CoChat

Monitoring of Anti-Xa in Pregnant Patients With Mechanical Prosthetic Valves Receiving Low-Molecular-Weight Heparin: Peak or Trough Levels?

Goland, Sorel, Schwartzenberg, Shmuel, Fan, John, Kozak, Natasha, Khatri, Nudrat, Elkayam, Uri · 2014 · Journal of Cardiovascular Pharmacology and Therapeutics
Cited by 64

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Objectives: We hypothesized that the guideline-recommended peak anti-Xa levels for pregnant women with mechanical prosthetic heart valves (MPHVs) receiving adjusted dose low-molecular-weight heparin (LMWH) are associated with subtherapeutic trough levels and consequently with an inadequate level of anticoagulation. Background: Low-molecular-weight heparin is often used for anticoagulation in pregnant women including those with MPHV. American College of Cardiology/American Heart Association guidelines recommend monitoring of plasma anti-Xa factor peak levels and adjustment of the dose to achieve peak levels of 0.7 to 1.2 U/mL. In spite of these recommendations, cases of valve thrombosis during pregnancy continue to occur. Methods and Results: We studied 30 pregnant patients receiving anticoagulation for various indications with adjusted dose LMWH given subcutaneously twice a day which had both trough and peak anti-Xa levels throughout pregnancy for a total of 187 paired determinations. The recommended peak anti-Xa levels (0.7-1.2 U/mL) were obtained in 123 (66%) of the measurements but in 80% of them, the trough levels were found to be subtherapeutic (<0.6 U/mL). Subtherapeutic trough levels were found in 8 (73%) of the 11 measurements with peak levels of 0.7 to 0.79 U/mL, 17 (74%) of the 23 of 0.8 to 0.89 U/mL, 21 (72%) of the 29 of 0.9 to 0.99 U/mL, and 28 (44%) of the 63 of 1.0 to 1.2 U/mL. There were 42 measurements with peak anti-Xa levels >1.2 U/mL and even in these cases, 13 (31%) of the trough levels were found to be subtherapeutic. Conclusions: Anticoagulation with adjusted dose LMWH aimed to achieve guideline-recommended peak levels of anti-Xa for patients with MPHVs is commonly associated with subtherapeutic trough levels. Routine measurement of trough anti-Xa levels is therefore advisable in women with MPHV treated with LMWH during pregnancy to assure adequate level of anticoagulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1074248414524302

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • ESC Guidelines on the management of cardiovascular diseases during pregnancy

    Endorsed by the European Society of Gynecology (ESG), T. A. F. E. P. C. (., Authors/Task Force Members, Regitz-Zagrosek, V., Blomstrom Lundqvist, C., Borghi, C., Cifkova, R., Ferreira, R., Foidart, J.-M., Gibbs, J. S. R., Gohlke-Baerwolf, C., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr218 · Cited by 1,924

    Self-citation
  • VTE, Thrombophilia, Antithrombotic Therapy, and Pregnancy

    Bates, S. M., Greer, I. A., Middeldorp, S., Veenstra, D. L., Prabulos, A.-M., & Vandvik, P. O. (2012) · Chest · doi:10.1378/chest.11-2300 · Cited by 1,525 · cited 1×

    “A careful review of the reported cases, however, suggested that most of them were associated with an inadequate dose, lack of monitoring, or subtherapeutic anti-Xa levels.(14-22,28) A recent review by McLintock(2) has summarized the maternal and fetal complications in 92 women from 5 prospective cohort studies treated…”
    Background

Show all 2 references

Cited by

Metadata

Authors
Goland, S., Schwartzenberg, S., Fan, J., Kozak, N., Khatri, N., & Elkayam, U.
Venue
Journal of Cardiovascular Pharmacology and Therapeutics
Published
2014-03-06
Volume
19
Issue
5
Pages
451-456
ISSN
  • 1074-2484 (ISSN-L)
  • 1940-4034
OpenAlex
W2146469650
Cited by
64
References
2
FWCI
3.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.