Abstract
The tissue electrode interface is common to all forms of biopotential recording (e.g., ECG, EMG, EEG) and functional electrical stimulation (e.g., pacemaker, cochlear implant, deep brain stimulation). Conventional lumped element circuit models of electrodes can be extended by generalization of the order of differentiation through modification of the defining current-voltage relationships. Such fractional order models provide an improved description of observed bioelectrode behaviour, but recent experimental studies of cardiac tissue suggest that additional mathematical tools may be needed to describe this complex system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applications of Fractional Calculus in Physics
Hilfer, R. (2000) · WORLD SCIENTIFIC eBooks · doi:10.1142/3779 · Cited by 4,788
Dielectric relaxation in solids
Henisch, H. K. (1984) · Materials Research Bulletin · doi:10.1016/0025-5408(84)90019-9 · Cited by 3,360
Electrical Properties of Tissue and Cell Suspensions
Schwan, H. P. (1957) · Advances in Biological and Medical Physics · doi:10.1016/b978-1-4832-3111-2.50008-0 · Cited by 1,620 · cited 1×
“…circuit can serve as a first order model for both macro and micro-electrodes, describe the skin-tissue interface for ECG electrodes, and model the behavior of electrodes in contact with single cells, cell suspensions and whole tissues (Schwan, 1957, 1968 Greatbatch and Chardack, 1968 Dymond, 1976).”
BackgroundBioimpedance and Bioelectricity Basics
(2015) · Elsevier eBooks · doi:10.1016/c2012-0-06951-7 · Cited by 1,175
Fractional Calculus in Bioengineering, Part 1
Magin, R. L. (2004) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v32.10 · Cited by 616
Self-citationFractal dimension and fractional power frequency-dependent impedance of blocking electrodes
Nyikos, L., & Pajkossy, T. (1985) · Electrochimica Acta · doi:10.1016/0013-4686(85)80016-5 · Cited by 480 · cited 1×
“There is even some hope for a simple connection between fractal tissue electrode structure and fractional order dynamics (Nyikos and Pajkossy, 1985).”
BackgroundELECTRODE POLARIZATION IMPEDANCE AND MEASUREMENTS IN BIOLOGICAL MATERIALS*
Schwan, H. P. (1968) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1968.tb20349.x · Cited by 368 · cited 1×
“…circuit can serve as a first order model for both macro and micro-electrodes, describe the skin-tissue interface for ECG electrodes, and model the behavior of electrodes in contact with single cells, cell suspensions and whole tissues (Schwan, 1957, 1968 Greatbatch and Chardack, 1968 Dymond, 1976).”
BackgroundPlonsey, R. (1999) · Wiley Encyclopedia of Electrical and Electronics Engineering · doi:10.1002/047134608x.w1403 · Cited by 335
Electrodes and the measurement of bioelectric events
Shipton, H. W. (1973) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(73)90185-5 · Cited by 303
Reilly, J. P. (1998) · Springer eBooks · doi:10.1007/978-1-4612-1664-3 · Cited by 295
Non-exponential decay in dielectrics and dynamics of correlated systems
Dissado, L. A., & Hill, R. M. (1979) · Nature · doi:10.1038/279685a0 · Cited by 284 · cited 1×
“Physicists employ statistical mechanics to describe observed t behavior (Dissado and Hill, 1979) and anomalous diffusion via continuous-time random walk models in solids and liquids (Hilfer, 2000).”
BackgroundElectrodes and the measurement of bioelectric events
Geddes, L. A. (1972) · Medical Entomology and Zoology · Cited by 281
Applied Bioelectricity: from Electrical Stimulation to Electropathology
Reilly, J. P. (1999) · Physiological Measurement · doi:10.1088/0967-3334/20/2/701 · Cited by 277 · cited 3×
“Much effort has been directed toward the development of accurate impedance models for electrophysiological recording and electrical stimulation (Plonsey, 1969 Gulrajani, 1998 Reilly, 1998).”
BackgroundBioelectricity and biomagnetism
Gulrajani, R. M. (1998) · Cited by 217
Fractional Calculus in Bioengineering, Part3
Magin, R. L. (2004) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v32.i34.10 · Cited by 184
Self-citationProbing ion-channel pores one proton at a time
Cymes, G. D., Ni, Y., & Grosman, C. (2005) · Nature · doi:10.1038/nature04293 · Cited by 159 · cited 2×
“From microelectrode recording of voltage-gated ion channels, whose conductance and subconductance states can reflect single amino acid substitutions (Cymes et al., 2005), to macroelectrode stimulation for cardiac defibrillation (Reilly, 1998), critical design parameters are either not known or not being observed.”
BackgroundCharacteristics of the Metal-Tissue Interface of Stimulation Electrodes
Dymond, A. M. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324585 · Cited by 121 · cited 1×
“…circuit can serve as a first order model for both macro and micro-electrodes, describe the skin-tissue interface for ECG electrodes, and model the behavior of electrodes in contact with single cells, cell suspensions and whole tissues (Schwan, 1957, 1968 Greatbatch and Chardack, 1968 Dymond, 1976).”
BackgroundMYOCARDIAL AND ENDOCARDIAC ELECTRODES FOR CHRONIC IMPLANTATION
Greatbatch, W., & Chardack, W. M. (1968) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1968.tb20352.x · Cited by 50 · cited 1×
“…circuit can serve as a first order model for both macro and micro-electrodes, describe the skin-tissue interface for ECG electrodes, and model the behavior of electrodes in contact with single cells, cell suspensions and whole tissues (Schwan, 1957, 1968 Greatbatch and Chardack, 1968 Dymond, 1976).”
BackgroundOvadia, M., Zavitz, D. H., Rubinson, J. F., Park, D., & Chou, H. A. (2005) · Chemical Physics Letters · doi:10.1016/j.cplett.2005.11.053 · Cited by 9 · cited 2×
“Recent results from Ovadia et al. (2006a) describe experimentation in human fetal tissue that suggests nonlinear behavior, which could not always be fitted to a Havriliak-Negami fractional order dielectric model, and in some cases exhibited nonlinear behavior with harmonic generation.”
BackgroundSelf-citationOvadia, M., Fayn, E., & Zavitz, D. H. (2006) · Chemical Physics Letters · doi:10.1016/j.cplett.2006.04.054 · Cited by 6 · cited 2×
“Recent results from Ovadia et al. (2006a) describe experimentation in human fetal tissue that suggests nonlinear behavior, which could not always be fitted to a Havriliak-Negami fractional order dielectric model, and in some cases exhibited nonlinear behavior with harmonic generation.”
BackgroundSelf-citation
Cited by
Fractional calculus models of complex dynamics in biological tissues
Magin, R. L. (2010) · Computers & Mathematics with Applications · doi:10.1016/j.camwa.2009.08.039 · Cited by 1,011
Self-citationChen, J., Zeng, Z., & Jiang, P. (2014) · Neural Networks · doi:10.1016/j.neunet.2013.11.016 · Cited by 554
A Survey of Fractional-Order Circuit Models for Biology and Biomedicine
Freeborn, T. J. (2013) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2013.2265797 · Cited by 353
Fractional Calculus in Image Processing: A Review
Yang, Q., Chen, D., Zhao, T., & Chen, Y. (2016) · Fractional Calculus and Applied Analysis · doi:10.1515/fca-2016-0063 · Cited by 315
LMI Conditions for Global Stability of Fractional-Order Neural Networks
Zhang, S., Yu, Y., & Yu, J. (2017) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2016.2574842 · Cited by 201
Metadata
- Authors
- Magin, R. L., & Ovadia, M.
- Venue
- Journal of Vibration and Control
- Publisher
- SAGE Publications
- Published
- 2008-09
- Volume
- 14
- Issue
- 9-10
- Pages
- 1431-1442
- ISSN
- 1077-5463 (ISSN-L)
- 1741-2986
- OpenAlex
- W2050765441
- Cited by
- 201
- References
- 20
- FWCI
- 0.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.