The DOI matches its Crossref record; 164 of the 164 references it cites were found in a registry or an index.
Vibration suppression of structures using tuned mass damper technology: A state-of-the-art review
Open accessAbstract
To date, considerable attention has been paid to the development of structural vibration suppression techniques. Among all vibration suppression devices and techniques, the tuned mass damper is one of the most promising technologies due to its mechanical simplicity, cost-effectiveness, and reliable operation. In this article, a critical review of the structural vibration suppression using tuned mass damper technology will be presented mainly focused on the following four categories: (1) tuned mass damper technology and its modifications, (2) tuned mass damper technology in discrete and continuous structures (mathematical modeling), (3) optimization procedure to obtain the optimally designed tuned mass damper system, and (4) active tuned mass damper and semi-active tuned mass damper with the practical realization of the tuned mass damper technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weiss, M. (1997) · Automatica · doi:10.1016/s0005-1098(97)00132-5 · Cited by 5,495
Engineering Optimization Theory and Practice
Rao, S. S. (2019) · Wiley eBooks · doi:10.1002/9781119454816 · Cited by 3,578
BISHOP, R. E. D. (1957) · Nature · doi:10.1038/179504a0 · Cited by 1,636
(1990) · Discrete Applied Mathematics · doi:10.1016/0166-218x(90)90039-f · Cited by 1,440
Induced Fibration of Suspensions
Winslow, W. M. (1949) · Journal of Applied Physics · doi:10.1063/1.1698285 · Cited by 1,235
Optimum absorber parameters for various combinations of response and excitation parameters
Warburton, G. B. (1982) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290100304 · Cited by 1,043
Theory of Vibration with Applications
Thomson, W. T. (2018) · CRC Press eBooks · doi:10.1201/9780203718841 · Cited by 989
Random Vibration in Mechanical Systems
(1963) · Elsevier eBooks · doi:10.1016/c2013-0-12506-8 · Cited by 899
Marian, L., & Giaralis, A. (2014) · Probabilistic Engineering Mechanics · doi:10.1016/j.probengmech.2014.03.007 · Cited by 828
Seismic control of single‐degree‐of‐freedom structure using tuned viscous mass damper
Ikago, K., Saito, K., & Inoue, N. (2012) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.1138 · Cited by 782
Cited by
Tuned mass damper inerter for seismic control of multi-story buildings: Ten years since inception
Konar, T., & Ghosh, A. (. (2024) · Structures · doi:10.1016/j.istruc.2024.106459 · Cited by 57
Metadata
- Authors
- Yang, F., Sedaghati, R., & Esmailzadeh, E.
- Venue
- Journal of Vibration and Control
- Publisher
- SAGE Publications
- Published
- 2021-02-01
- Volume
- 28
- Issue
- 7-8
- Pages
- 812-836
- ISSN
- 1077-5463 (ISSN-L)
- 1741-2986
- OpenAlex
- W3128777719
- Cited by
- 306
- References
- 164
- FWCI
- 19.05
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Vibration suppression of structures using tuned mass damper technology: A state-of-the-art review. https://app.cochat.ai/papers/10.1177/1077546320984305
- The paper
- Yang, F., Sedaghati, R., & Esmailzadeh, E. (2022). Vibration suppression of structures using tuned mass damper technology: A state-of-the-art review. Journal of Vibration and Control. https://doi.org/10.1177/1077546320984305
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.