CoChat

The change of microglia numbers within the mice retina, optic nerve and chiasm following intravitreal AAV2-GFP injection

Ji, Yuanfei, Yu, Bo, Zhang, Yikui, Wu, Wencan · 2022 · European Journal of Ophthalmology

The DOI matches its Crossref record; the references it cites are not checked yet.

Abstract

Purpose: To explore the optimized concentration of AAV2-GFP for sparse transfection of retinal ganglion cells (RGCs) and optic nerve (ON), and to examine the changes of microglial morphology and distribution in the retina, optic nerve and chiasm after injection. Methods: We defined the optimal concentration of AAV2-GFP for sparse labeling of RGCs and axons in WT mice. We further explored the changes of microglial morphology and distribution in the retina, optic nerve and chiasm after intravitreal injection in CX3CR1+/GFP mice. Results: 14 days after intravitreal injection of AAV2-GFP, live imaging of the retina showed that fundus fluorescence was very strong and dense at 2.16 × 10 11 VG/retina, 2.16 × 10 10 VG/retina, 2.16 × 10 9 VG/retina. RGCs were sparsely marked at a concentration 1:1000 (2.16 × 10 8 VG/retina) and fundus fluorescence was weak. The transfected RGCs and axons were unevenly distributed in the retina and significantly more RGCs were transfected near the injection site of AAV2-GFP compared to the other sites of the flat-mounted retina. Microglia density increased significantly in the retina and part of optic nerve, but not in the optic chiasm. The morphology of microglia was largely unchanged. Conclusions: AAV2-GFP was highly efficient and the optimal concentration of sparsely labeled RGCs was 1:1000 (2.16 × 10 8 VG/retina). After intravitreal injection of AAV2-GFP, the number of microglia increased partly. The morphology of microglia was comparable.

Overview

Integrity signals

Registry

Crossref · 10.1177/11206721211049001

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

The citation lists are queued

They are fetched later and appear here then.

References 47 · Cited by 3

Research works printed but not linked: 1

  1. Pang J, Cheng M, Haire SE, Barker E, Planelles V, Blanks JC. Efficiency of lentiviral transduction during development in normal and rd mice. Mol Vis 2006; 12: 756–67.

Metadata

Authors
Ji, Y., Yu, B., Zhang, Y., & Wu, W.
Affiliations
Wenzhou Medical University (CN)
Corresponding author
Wu, Wencan
Venue
European Journal of Ophthalmology
Published
2021-12-30
Volume
32
Issue
5
Pages
2589-2597
ISSN
  • 1120-6721 (ISSN-L)
  • 1724-6016
OpenAlex
W4200107348
Cited by
3
References
47
Citations by year
2026: 1 · 2025: 1 · 2024: 1
FWCI
0.14
Type
journal article
Language
en
Open access
closed
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • European Journal of Ophthalmology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Virus-based gene therapy research
  • Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
  • Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
Keywords
intravitreal injection, retinal ganglion cells, microglial morphology, optic nerve, optic chiasm, transfection efficiency, CX3CR1-GFP mice, retinal gene therapy
MeSH terms
Animals, Optic Nerve, Retina, Retinal Ganglion Cells, Microglia, Mice, Intravitreal Injections

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The change of microglia numbers within the mice retina, optic nerve and chiasm following intravitreal AAV2-GFP injection. https://app.cochat.ai/papers/10.1177/11206721211049001
The paper
Ji, Y., Yu, B., Zhang, Y., & Wu, W. (2022). The change of microglia numbers within the mice retina, optic nerve and chiasm following intravitreal AAV2-GFP injection. European Journal of Ophthalmology. https://doi.org/10.1177/11206721211049001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.