Deep gray matter T2 hypointensity is present in patients with clinically isolated syndromes suggestive of multiple sclerosis
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Gray matter (GM) magnetic resonance imaging (MRI) T2 hypointensity, a putative marker of iron deposition, is a frequent finding in patients with clinically definite (CD) multiple sclerosis (MS). The objective of this study was to assess: (a) how early deep GM T2 hypointensity occurs in MS, by studying patients with clinically isolated syndromes (CIS) suggestive of MS, and (b) whether they contribute to predict subsequent evolution to CDMS. Dual-echo scans using two different acquisition protocols were acquired from 47 CIS patients and 13 healthy controls (HC). Normalized T2-intensity of the basal ganglia and thalamus was quantified. Patients were assessed clinically at the time of MRI acquisition and after three years. During the observation period, 18 patients (38%) evolved to CDMS. At the baseline, only the GM T2-intensity of the left caudate nucleus was significantly reduced in CIS patients in comparison with the HC (p = 0.04). At the baseline, the T2 intensity of the left caudate nucleus was significantly lower (p = 0.01) in CIS patients with disease dissemination in space (DIS), but not in those without DIS, compared to the HC. The baseline T2 lesion volume, but not GM T2 hypointensity, was associated with evolution to CDMS (hazard ratio = 1.60, 95% confidence interval (CI) = 1.05—2.42; p = 0.02). In CIS patients, deep GM is not spared, suggesting that iron-related changes and neurodegeneration occurs early. The magnitude of such damage is only minor and not associated with an increased risk of evolution to CDMS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neema, M., Arora, A., Healy, B. C., Guss, Z. D., Brass, S. D., Duan, Y., Buckle, G. J., Glanz, B. I., Stazzone, L., Khoury, S. J., et al. (2009) · Journal of Neuroimaging · doi:10.1111/j.1552-6569.2008.00296.x · Cited by 128
Self-citationMRI T2 shortening (‘black T2’) in multiple sclerosis: frequency, location, and clinical correlation
Bakshi, R., Shaikh, Z. A., & Janardhan, V. (2000) · NeuroReport · doi:10.1097/00001756-200001170-00004 · Cited by 92
Self-citation
Cited by
Kell, D. B. (2010) · Archives of Toxicology · doi:10.1007/s00204-010-0577-x · Cited by 361
“…and/or deposition have indeed been implicated directly (Adams 1988; Bakshi et al. 2000, 2001, 2002, 2008; Bermel et al. 2005; Brass et al. 2006a, b; Ceccarelli et al. 2009, 2010; Chard and Miller 2009; Craelius et al. 1982; Drayer et al. 1987; Eissa et al. 2009; Exley et al. 2006; Filippi and…”
MR Imaging of Multiple Sclerosis
Filippi, M., & Rocca, M. A. (2011) · Radiology · doi:10.1148/radiol.11101362 · Cited by 281
Self-citationQuantitative Susceptibility Mapping in Multiple Sclerosis
Langkammer, C., Liu, T., Khalil, M., Enzinger, C., Jehna, M., Fuchs, S., Fazekas, F., Wang, Y., & Ropele, S. (2013) · Radiology · doi:10.1148/radiol.12120707 · Cited by 280
Rapid and accurate T2 mapping from multi–spin‐echo data using Bloch‐simulation‐based reconstruction
Ben‐Eliezer, N., Sodickson, D. K., & Block, K. T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25156 · Cited by 224
“Quantitative T2 mapping has demonstrated merit for various applications including neurodegenerative diseases (1,2), characterization of cancerous lesions (3–5), detection of biochemical and biophysical changes in hip and knee cartilage (6–9), diagnosis of stroke (10), assessment of diseased and posttransplant myocardi…”
Zivadinov, R., Brown, M. H., Schirda, C. V., Poloni, G. U., Bergsland, N., Magnano, C. R., Durfee, J., Kennedy, C., Carl, E., Hagemeier, J., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.045 · Cited by 188
“…given the large patient sample size used in this study, our findings suggest that iron deposition is a continuous process present from the earliest relapsing stages (Ceccarelli et al., 2010, 2011; Khalil et al., 2009) and increasing in the progressive phases of the disease (Bakshi et al., 2002).”
Metadata
- Authors
- Ceccarelli, A., Rocca, M. A., Neema, M., Martinelli, V., Arora, A., Tauhid, S., Ghezzi, A., Comi, G., Bakshi, R., & Filippi, M.
- Venue
- Multiple Sclerosis Journal
- Publisher
- SAGE Publications
- Published
- 2009-11-13
- Volume
- 16
- Issue
- 1
- Pages
- 39-44
- ISSN
- 1352-4585 (ISSN-L)
- 1477-0970
- OpenAlex
- W2090578466
- Cited by
- 61
- References
- 2
- FWCI
- 5.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.