Digital Storage of Glass Slides for Quality Assurance in Histopathology and Cytopathology
The DOI matches its Crossref record.
Abstract
Proficiency testing programmes for measuring screening skills in pathology are mainly conducted using conventional glass microscope slides. However, the availability of robotic microscopes allows an entire conventional slide to be digitized. Our experiments have shown that, using a widely available robotized microscope and a PC, the image of a single field may be acquired in 2 s on average, including stage movements, autofocus and storage. Digitizing an entire slide, a fully automated procedure, takes up to 8 h. If the image of each field is compressed at an appropriate quality level (a compression ratio of, say, 35:1) it requires about 40 kByte to be stored, resulting in a total storage requirement of about 600 MByte per slide. Thus one CD-ROM can be used to store one virtual slide, as well as a self-installing program to provide a microscope simulator facility. This allows pathologists to examine the virtual case from their computer in a similar manner to looking at a glass slide on a conventional microscope. This permits a new, computer-based approach to proficiency testing in histopathology and cytopathology. Use of virtual slides should encourage the diffusion of national quality assurance programmes, which at present suffer from certain organizational and logistical limitations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 18
- 10.1093/ajcp/112.6.769 · doi:10.1093/ajcp/112.6.769
- 10.1159/000328613 · doi:10.1159/000328613
- 10.1177/106689690000800401 · doi:10.1177/106689690000800401
- 10.1002/dc.10021 · doi:10.1002/dc.10021
- Haroske G, 1998, Advances in Clinical Pathology, 2, 143
- Kayser K, 1999, Analytical and Quantitative Cytology and Histology, 21, 319
- 10.1089/15305620050503834 · doi:10.1089/15305620050503834
- 10.1159/000331352 · doi:10.1159/000331352
- Afework A, Beynon MD, Bustamante F, Digital dynamic telepathology—the Virtual Microscope. Proceedings AMIA Annual Symposium 1998:912–16.
- http://www.telepathology.dcu.ie/intro.php3. Last checked 13 February 2002. · doi:10.1007/978-3-322-93249-5_2
- Costello SSP, Johnston DJ, Dervan PA, O'Shea DG. The virtual pathology slide: A new tool for Internet-based telepathology. Journal of Telemedicine and Telecare (in press).
- 10.1155/2000/745703 · DOI
- Demichelis F, Barbareschi M, Dalla Palma P, Forti S. The Virtual Case. A new method to completely digitise cytological and histological slides. Vtrchows Archiv (in press).
- 10.1002/(SICI)1096-9896(200005)191:1<1::AID-PATH624>3.0.CO;2-S · DOI
- 10.1002/path.972 · DOI
- 10.1053/hupa.2001.23057 · doi:10.1053/hupa.2001.23057
- 10.1016/S0046-8177(00)80190-2 · DOI
- 10.1155/2000/154031 · DOI
Cited by
Overview of telepathology, virtual microscopy, and whole slide imaging: Prospects for the future
Weinstein, R. S., Graham, A. R., Richter, L. C., Barker, G. P., Krupinski, E. A., Lopez, A. M., Erps, K. A., Bhattacharyya, A. K., Yagi, Y., & Gilbertson, J. R. (2009) · Human Pathology · doi:10.1016/j.humpath.2009.04.006 · Cited by 380
“There is extensive literature on digital imaging [9,10,16,19,21-23].”
BackgroundPrimary histologic diagnosis using automated whole slide imaging: a validation study
Gilbertson, J. R., Ho, J., Anthony, L., Jukic, D. M., Yagi, Y., & Parwani, A. V. (2006) · BMC Clinical Pathology · doi:10.1186/1472-6890-6-4 · Cited by 195
“Despite these promises, however, there exists only a relatively small number of papers describing automated WSI in education and research [1-6], far fewer directly comparing automated WSI with traditional microscope examination in diagnosis [7-11], and virtually none describing automated WSI in clinical practice.”
BackgroundImage standards in tissue-based diagnosis (diagnostic surgical pathology)
Kayser, K., Görtler, J., Goldmann, T., Vollmer, E., Hufnagl, P., & Kayser, G. (2008) · Diagnostic Pathology · doi:10.1186/1746-1596-3-17 · Cited by 56
Hypertext atlas of dermatopathology with expert system for epithelial tumors of the skin
Feit, J., Kempf, W., Jedličková, H., & Burg, G. (2005) · Journal of Cutaneous Pathology · doi:10.1111/j.0303-6987.2005.00291.x · Cited by 13
“Images of much higher resolution can be acquired, however, by composing of large images from smaller ones,(5) thus enabling to cover large areas of a slide or even the whole specimen (virtual microscope).(6) This approach was used in digitizing the tissue specimens for the image collection described in this article: h…”
Method
Metadata
- Authors
- Demichelis, F., Della Mea, V., Forti, S., Palma, P. D., & Beltrami, C. A.
- Venue
- Journal of Telemedicine and Telecare
- Publisher
- SAGE Publications
- Published
- 2002-06
- Volume
- 8
- Issue
- 3
- Pages
- 138-142
- ISSN
- 1357-633X (ISSN-L)
- 1758-1109
- OpenAlex
- W2019895296
- Cited by
- 64
- References
- 0
- FWCI
- 5.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Digital Storage of Glass Slides for Quality Assurance in Histopathology and Cytopathology. https://app.cochat.ai/papers/10.1177/1357633x0200800303
- The paper
- Demichelis, F., Della Mea, V., Forti, S., Palma, P. D., & Beltrami, C. A. (2002). Digital Storage of Glass Slides for Quality Assurance in Histopathology and Cytopathology. Journal of Telemedicine and Telecare. https://doi.org/10.1177/1357633x0200800303
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.