A Health Monitoring System for Elderly People Living Alone
The DOI matches its Crossref record.
Abstract
We have developed a health monitoring system for elderly people living alone. We monitored the in-house movements of eight subjects (average age 81 years) by placing infrared sensors in each room of their homes. Because their movements were unrestricted, monitoring could last longer than other forms of monitoring. Continuous monitoring was performed for 80 months in total. We found that each subject had a specific pattern of movements. We estimated their health condition by comparing the duration of stays in specific rooms, such as the lavatory, with previously recorded data. If after analysis an unusual state was detected, we informed the family of the incident. Final decisions should be made by the family members, not automatically by computer software. For example, after contacting the subject or a neighbour by telephone, family members could call for an ambulance or arrange a visit by a doctor or home help. Thus, this system reduced anxiety for both the elderly subjects living alone and their family members.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Smart health monitoring systems: An overview of design and modeling
Baig, M. M., & Gholamhosseini, H. (2013) · Journal of Medical Systems · doi:10.1007/s10916-012-9898-z · Cited by 396
Heart rate measurement based on a time-lapse image.
Takano, C., & Ohta, Y. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.09.006 · Cited by 345
A Zigbee-Based Wearable Physiological Parameters Monitoring System
Malhi, K., Mukhopadhyay, S. C., Schnepper, J., Haefke, M., & Ewald, H. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2091719 · Cited by 282
Colombo, D., Fernández-Álvarez, J., Patané, A., Semonella, M., Kwiatkowska, M., García-Palacios, A., Cipresso, P., Riva, G., & Botella, C. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8040465 · Cited by 194
Tian, Y. J., Felber, N. A., Pageau, F., Schwab, D. R., & Wangmo, T. (2024) · BMC Geriatrics · doi:10.1186/s12877-024-04702-1 · Cited by 123
“Within this category, included studies mentioned technologies that could detect abnormality in postures, movements including falls, signs of agitation, and lights turning on at abnormal times (e.g. [ 25–28]).”
Background
Metadata
- Authors
- Ohta, S., Nakamoto, H., Shinagawa, Y., & Tanikawa, T.
- Venue
- Journal of Telemedicine and Telecare
- Publisher
- SAGE Publications
- Published
- 2002-06
- Volume
- 8
- Issue
- 3
- Pages
- 151-156
- ISSN
- 1357-633X (ISSN-L)
- 1758-1109
- OpenAlex
- W1986551786
- Cited by
- 156
- References
- 0
- FWCI
- 3.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Health Monitoring System for Elderly People Living Alone. https://app.cochat.ai/papers/10.1177/1357633x0200800305
- The paper
- Ohta, S., Nakamoto, H., Shinagawa, Y., & Tanikawa, T. (2002). A Health Monitoring System for Elderly People Living Alone. Journal of Telemedicine and Telecare. https://doi.org/10.1177/1357633x0200800305
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.