Thermal Comfort Investigation of Naturally Ventilated Classrooms in a Subtropical Region
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A field study of student thermal comfort was conducted in the Chinese subtropics. Thermal comfort affects people's physical and psychological health. The study was performed in Hunan University in China from March 24 to April 23 in 2005. Two teaching buildings were selected as study sites. Thermal comfort was measured in naturally ventilated classrooms with ceiling fans. A total of 25 classrooms were surveyed and each classroom was visited two or three times and 1273 students responded to the questionnaire. Thermal comfort variables were measured at the same time: students answered a survey on their perception/sensation of the indoor climate. Objective data analysis showed that most respondents found thermal satisfaction during the sampling month, even though the indoor air temperature and relative humidity varied greatly, with average values at 20 °C and 71%, respectively. The thermal neutral temperature calculated by Thermal Sensation Vote (TSV) was at about 21.5 °C and the slope of the regression line relating TSV with operative temperature was 0.0448/°C, which is quite different from that found in other similar thermal comfort studies. This difference is attributed to the different climate and adaptation and tolerance of students, who were the study subjects. There was a relatively large gap between studiedTSV and Predicted Mean Vote (PMV). An extended PMV model that incorporated two common forms of adaptation — reducing activity pace and expectation — was also considered, but the discrepancy between predicted and studied thermal sensations did not reduce noticeably, especially at the lower temperatures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Extension of the PMV model to non-air-conditioned buildings in warm climates
Ole Fanger, P., & Toftum, J. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00003-8 · Cited by 853
Cited by
A review of human thermal comfort in the built environment
Rupp, R. F., Vásquez, N. G., & Lamberts, R. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.07.047 · Cited by 907
“a modified model of PMV, but the discrepancy between predicted and actual thermal sensations did not reduce noticeably [210].”
BackgroundProgress in thermal comfort research over the last twenty years
de Dear, R. J., Akimoto, T., Arens, E. A., Brager, G., Candido, C., Cheong, K. W. D., Li, B., Nishihara, N., Sekhar, S. C., Tanabe, S., et al. (2013) · Indoor Air · doi:10.1111/ina.12046 · Cited by 523
Thermal comfort in educational buildings: A review article
Zomorodian, Z. S., Tahsildoost, M., & Hafezi, M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.033 · Cited by 460
Field studies on human thermal comfort — An overview
Mishra, A. K., & Ramgopal, M. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.02.015 · Cited by 336
Teli, D., Jentsch, M. F., & James, P. A. B. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.06.022 · Cited by 284
Metadata
- Authors
- Zhang, G., Zheng, C., Yang, W., Zhang, Q., & Moschandreas, D. J.
- Venue
- Indoor and Built Environment
- Publisher
- SAGE Publications
- Published
- 2007-04
- Volume
- 16
- Issue
- 2
- Pages
- 148-158
- ISSN
- 1420-326X (ISSN-L)
- 1423-0070
- OpenAlex
- W2026717294
- Cited by
- 120
- References
- 1
- FWCI
- 16.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thermal Comfort Investigation of Naturally Ventilated Classrooms in a Subtropical Region. https://app.cochat.ai/papers/10.1177/1420326x06076792
- The paper
- Zhang, G., Zheng, C., Yang, W., Zhang, Q., & Moschandreas, D. J. (2007). Thermal Comfort Investigation of Naturally Ventilated Classrooms in a Subtropical Region. Indoor and Built Environment. https://doi.org/10.1177/1420326x06076792
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.