Monitoring Viable Fungal and Bacterial Bioaerosol Concentrations to Identify Acceptable Levels for Common Indoor Environments
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Little characterization of bioaerosol concentrations between 200 and 450 cfu.m-3 has been carried out to address potential concerns about indoor air quality. The present research describes measurements of indoor bioaerosol concentrations and concludes that a level of nontoxigenic and nonpathogenic organisms ≤ 300 cfu·m -3 should be typical for environments in which nor mal, nonimmunocompromised people live. With the exception of Cladospo rium, no organism should individually contribute more than 50 cfu·m -3 to the total. The author believes that levels >300 cfu·m -3 and/or not meeting the above criteria require further investigation for: a bias from prominent outdoor bioaerosol(s), inadequate air filtration, excessive indoor humidity and micro- humidity environments, and/or potential indigenous contamination source(s). This is not to say that a level of contamination > 300 cfu·m -3 represents any threshold having medical or health significance nor necessarily that it is repre sentative of an unacceptable indoor environment. Rather it is proposed as a 'reactionary threshold' to incite further investigation into the cause(s) of what, from the measurements made, is an above average viable concentration for indoor bioaerosols. It is also concluded that outdoor sampling should only be carried out for comparisons with individual indoor components and that indoor/outdoor ratios involving total cfu·m -3 concentrations should not be used for evaluating acceptable indoor bioaerosol concentrations.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Li and Kendrick (32) and Robertson (46) showed that the concentrations of fungal fragments in indoor air can reach an average level of 29 to 146 pieces per m3, i.e., up to 6.3% of all fungal propagules indoors.”
From Fungal Fragments as Indoor Air Biocontaminants (2002) · cites this paper as [46]
Citations
Cites
Illustrated Genera of Imperfect Fungi
(1955) · Transactions of the British Mycological Society · doi:10.1016/s0007-1536(55)80058-7 · Cited by 2,974
(1971) · Annals of Internal Medicine · doi:10.7326/0003-4819-75-6-991_4 · Cited by 2,379
Handbook of Microbiological Media
Atlas, R. M., & Atlas, R. M. (2004) · CRC Press eBooks · doi:10.1201/9781420039726 · Cited by 2,149
Illustrated Genera of Imperfect Fungi
K., R. P., Barnett, H. L., & Hunter, B. B. (1972) · Mycologia · doi:10.2307/3757954 · Cited by 1,375
Medically Important Fungi: A Guide to Identification
Larone, D. H. (1976) · Cited by 809
Medically important fungi: A guide to identification
Ajello, L. (1989) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/0732-8893(89)90040-0 · Cited by 662
Clinical Diagnosis by Laboratory Methods.
(1953) · Annals of Internal Medicine · doi:10.7326/0003-4819-39-4-962_2 · Cited by 500
Kendrick, B. (2001) · Medical Entomology and Zoology · Cited by 341
Handbook of microbiological media
(1994) · Choice Reviews Online · doi:10.5860/choice.31-5434 · Cited by 285
Practical Handbook of Microbiology
Green, L. H., & Goldman, E. (2021) · CRC Press eBooks · doi:10.1201/9781003099277 · Cited by 276
Research works printed but not linked: 14
- Burge H., 1993, Committee on the Health Effects of Indoor Allergens, Division of Health Promotion and Disease Prevention, Indoor Allergens
- Kwon-Chung KJ, 1992, Medical Mycology
- Pope AM, 1993, Indoor Allergens
- Walsh PJ, 1989, Indoor Air Quality
- Burge H., 1995, Bioaerosols
- Cox CS, 1995, Bioaerosols Handbook
- Robertson LD, 1995, Plant Technology & Safety Management Series, 23
- American Conference of Governmental Industrial Hygienists (ACGIH): Guideline for the Assessment of Bioaerosols in the Indoor Environment
- Morey PR, 1989, Health and Comfort, 67
- Yang CS, Indoor Air '93 International Conference
- Toth C., Proc First Annu IAQ Conf Exposition
- Pasanen AL, Proc Indoor Air '90: 5th Int Conf Indoor Air Quality Climate
- Reponen T., Proc Indoor Air '90: 5th Int Conf Indoor Air Quality Climate
- Holt GL, 1993, Determination of Seasonal Indoor/ Outdoor Fungal Ratios and Indoor Bacterial Levels in NonComplaint Office Buildings; PhD thesis, Department of Environmental Health Sciences
Cited by
Fungal Fragments as Indoor Air Biocontaminants
Górny, R. L., Reponen, T., Willeke, K., Schmechel, D., Robine, E., Boissier, M., & Grinshpun, S. A. (2002) · Applied and Environmental Microbiology · doi:10.1128/aem.68.7.3522-3531.2002 · Cited by 402
Airborne fungal fragments and allergenicity
Green, B. J., Tovey, E. R., Sercombe, J. K., Blachere, F. M., Beezhold, D. H., & Schmechel, D. (2006) · Medical Mycology · doi:10.1080/13693780600776308 · Cited by 214
Filamentous microorganisms and their fragments in indoor air--a review.
Górny, R. L. (2004) · PubMed · Cited by 172
Ambient bioaerosol indices for indoor air quality assessments of flood reclamation
Fabian, M. P., Miller, S. L., Reponen, T. A., & Hernandez, M. (2005) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2004.11.018 · Cited by 131
Indoor Air Quality and Thermal Comfort—Results of a Pilot Study in Elderly Care Centers in Portugal
Mendes, A., Pereira, C. C., Mendes, D., Aguiar, L., Neves, P. M. M. D. C., Silva, S., Batterman, S., & Teixeira, J. P. (2013) · Journal of Toxicology and Environmental Health · doi:10.1080/15287394.2013.757213 · Cited by 108
Mulec, J. (2013) · Journal for Nature Conservation · doi:10.1016/j.jnc.2013.10.001 · Cited by 97
Stachybotrys chartarum: cause of human disease or media darling?
Miller, J. D., Rand, T. G., & Jarvis, B. B. (2003) · Medical Mycology · doi:10.1080/1369378031000137350 · Cited by 104
Determinants of Microbial Exposure in Grain Farming
Halstensen, A. S., Nordby, K.-C., Wouters, I. M., & Eduard, W. (2007) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mem038 · Cited by 99
Foto, M., Vrijmoed, L. L. P., Miller, J. D., Ruest, K., Lawton, M., & Dales, R. E. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00370.x · Cited by 83
Experimental study of indoor and outdoor airborne bacterial concentrations in Tempe, Arizona, USA
Zhu, H. L., Phelan, P. E., Duan, T., Raupp, G. B., Fernando, H. J. S., & Fengxiang, C. (2003) · Aerobiologia · doi:10.1023/b:aero.0000006571.23160.8a · Cited by 72
Hussin, N. H. M., Sann, L. M., Shamsudin, M. N., & Hashim, Z. B. (2011) · Indoor and Built Environment · doi:10.1177/1420326x11414318 · Cited by 69
Assessment of Bioaerosol Concentrations in Different Indoor Environments
Zorman, T., & Jeršek, B. (2008) · Indoor and Built Environment · doi:10.1177/1420326x08089251 · Cited by 66
Mulec, J., Vaupotič, J., & Walochnik, J. (2012) · Microbial Ecology · doi:10.1007/s00248-012-0059-1 · Cited by 55
Xu, Z., & Yao, M. (2012) · Environmental Monitoring and Assessment · doi:10.1007/s10661-012-2844-1 · Cited by 50
Microbiological air quality in office buildings equipped with dventilation systems
Gołofit-Szymczak, M., & Górny, R. L. (2018) · Indoor Air · doi:10.1111/ina.12495 · Cited by 49
Detection and analysis of airborne particles of biological origin: present and future
Caruana, D. J. (2011) · The Analyst · doi:10.1039/c1an15506g · Cited by 43
Mulec, J., Oarga-Mulec, A., Šturm, S., Tomazin, R., & Matos, T. (2017) · Diversity · doi:10.3390/d9030028 · Cited by 34
Biological Air Contamination in Elderly Care Centers: Geria Project
Aguiar, L., Mendes, A., Pereira, C. C., Neves, P. M. M. D. C., Mendes, D., & Teixeira, J. P. (2014) · Journal of Toxicology and Environmental Health · doi:10.1080/15287394.2014.911135 · Cited by 24
Characterizations and relationships between outdoor and indoor bioaerosols in an office building
Zhu, H. L., Phelan, P. E., Duan, T., Raupp, G. B., & Fernando, H. J. S. (2003) · 中国颗粒学报:英文版 · doi:10.1016/s1672-2515(07)60122-5 · Cited by 23
Evaluation of ergosterol content in the air of various environments
Gutarowska, B., Skóra, J., & Pielech‐Przybylska, K. (2014) · Aerobiologia · doi:10.1007/s10453-014-9344-4 · Cited by 22
Assessment of fungal contamination in a group of Lisbon's Gymnasiums with a swimming Pool
Viegas, C., Alves, C. A., Carolino, E., Pinheiro, A. C., Rosado, L., & Santos, C. S. (2011) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 19
Occupational Exposure to Moulds in Buildings
Singh, J. (2001) · Indoor and Built Environment · doi:10.1159/000049233 · Cited by 19
Indoor Moulds and Their Associations with Air Distribution Systems
Ahearn, D. G., Price, D. L., Simmons, R. B., Noble‐Wang, J., & Crow, S. A. (2004) · Advances in applied microbiology · doi:10.1016/s0065-2164(04)55003-7 · Cited by 16
Review : Occupational Exposure to Moulds in Buildings
Singh, J. (2001) · Indoor and Built Environment · doi:10.1177/1420326x0101000309 · Cited by 16
Occurrence of Airborne Bacteria and Fungi in Bayside Offices in Rio de Janeiro, Brazil
Brickus, L. S. R., Siqueira, L. F. G., Neto, F. R. D. A., & Cardoso, J. N. (1998) · Indoor and Built Environment · doi:10.1159/000024595 · Cited by 16
Moshood, T. D., Rotimi, J. O. B., & Shahzad, W. M. (2023) · Construction Innovation · doi:10.1108/ci-10-2022-0273 · Cited by 28
Oh, J. H., Jeong, N.-N., Chi, W.-B., Seo, J., Jun, S.-M., & Sohn, J. (2015) · Environmental Science and Pollution Research · doi:10.1007/s11356-015-4810-2 · Cited by 13
Biological Contamination of the Building Environment: Sampling and Analysis
Fink, R. C., & Gilman, E. A. (2000) · Applied Biosafety · doi:10.1177/109135050000500106 · Cited by 7
Bacterial and fungal aerosols in the work environment of cleaners
Gołofit-Szymczak, M., Górny, R. L., Ławniczek-Wałczyk, A., Cyprowski, M., & Stobnicka-Kupiec, A. (2015) · Medycyna Pracy · doi:10.13075/mp.5893.00349 · Cited by 6
Vélez-Pereira, A. M., & Caicedo, Y. C. (2014) · Redalyc (Universidad Autónoma del Estado de México) · Cited by 3
Vélez-Pereira, A. M., & Caicedo, Y. C. (2014) · Revista CUIDARTE · Cited by 2
Developing a strategy for the implementation of sustainable construction practices in Libya
Khalil, A. (2018) · University of Salford Institutional Repository (University of Salford) · Cited by 6
Vélez-Pereira, A. M., & Caicedo, Y. C. (2014) · Revista Cubana de Salud Pública
Ocena bioaerosolov v delovnih prostorih
Jeršek, B., & Zorman, T. (2006) · Acta agriculturae Slovenica · doi:10.14720/aas.2006.87.2.15106
MORPHOFUNCTIONAL CHANGES IN RAT LUNGS UNDER THE INFLUENCE OF AFLATOXIN B1
Karapetyan, A. F., Grigoryan, A. V., & Avagyan, G. A. (2021) · Proceedings of the YSU B Chemical and Biological Sciences · doi:10.46991/pysu:b/2021.55.1.085
Metadata
- Authors
- Robertson, L. D.
- Affiliations
- Mycotech Biological, Inc., Jewett, Tex., USA
- Corresponding author
- Robertson, L.D.
- Venue
- Indoor and Built Environment
- Publisher
- SAGE Publications
- Published
- 1997-09
- Volume
- 6
- Issue
- 5
- Pages
- 295-300
- ISSN
- 1420-326X (ISSN-L)
- 1423-0070
- OpenAlex
- W2156204120
- Cited by
- 35
- References
- 24
- Citations by year
- 2023: 1 · 2021: 1 · 2018: 2 · 2017: 1 · 2015: 2 · 2014: 5 · 2013: 2 · 2012: 2
- FWCI
- 0.70
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Indoor and Built Environment (publishedVersion)
- OakTrust (Texas A&M University Libraries) (submittedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Keywords
- indoor bioaerosols, bacterial aerosols, indoor air quality, indoor-outdoor concentration ratio, indoor humidity, air filtration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.