CoChat

Temperature effects on cable stayed bridge using health monitoring system: a case study

Yinghong Cao, Yim, Jinsuk, Yang Zhao, Wang, Ming L · 2011 · Structural Health Monitoring
Cited by 142

The DOI matches its Crossref record.

Abstract

The Zhanjiang Bay Bridge, located in an inner gulf of South China, is a cable stayed bridge with a main span of 480 m. An analysis on the thermal effects experienced by the bridge is presented according to a health monitoring system (HMS) that began operation in 2006. The parameters studied in the analysis include thermal time lags and gradients of the steel box girder, concrete tower, and stayed cables, as well as displacements at center span and tops of the towers. Among the findings, temperature gradient in the steel girder was larger than the design specification, concrete temperature lagged significantly behind ambient air, and stayed cable temperatures were between those of ambient air and concrete. Additional findings were obtained by comparing the measured data to values calculated using a finite element model. The comparison made it possible to approximate the unmeasured thermal gradient on the surface of the towers, and to determine that an expansion joint was likely jammed and contributing to the bridge’s asymmetrical displacement. This article presents these findings in a thorough manner, and in doing so conveys the ability of a HMS to provide realistic examples of thermal behavior, to estimate conditions at locations free of measurement devices, and to suggest areas of concern for future manual inspections. Furthermore, it provides evidence that a HMS is not only helpful for bridge design and management, but also for the development of itself.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1475921710388970

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Metadata

Authors
Cao, Y., Yim, J., Zhao, Y., & Wang, M. L.
Venue
Structural Health Monitoring
Published
2010-11-23
Volume
10
Issue
5
Pages
523-537
ISSN
  • 1475-9217 (ISSN-L)
  • 1741-3168
OpenAlex
W2163558669
Cited by
142
References
0
FWCI
7.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Temperature effects on cable stayed bridge using health monitoring system: a case study. https://app.cochat.ai/papers/10.1177/1475921710388970
The paper
Cao, Y., Yim, J., Zhao, Y., & Wang, M. L. (2011). Temperature effects on cable stayed bridge using health monitoring system: a case study. Structural Health Monitoring. https://doi.org/10.1177/1475921710388970

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.