A scalable data-driven approach to temperature baseline reconstruction for guided wave structural health monitoring of anisotropic carbon-fibre-reinforced polymer structures
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
To account for the temperature effect on guided wave signals in complex structures, a significant amount of baseline measurements typically need to be collected over a large temperature range to serve as a library of signals at all possible temperatures, which, if not impossible, is highly impractical. This article presents a data-driven temperature baseline reconstruction approach that is applicable for various structures made from the same material. The influence of temperature on the amplitude and phase of guided wave measurements are experimentally quantified as dimensionless compensation factors. The derived compensation factors are used to reconstruct baselines at various temperatures for guided wave measurements in a simple flat plate and a stiffened panel. With a single baseline measurement at 20°C and the reconstructed baseline using the predetermined temperature compensation factors, impact damage was successfully detected and located when current measurements were up to 25°C and 20°C higher than the baseline temperature, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Temperature effects in ultrasonic Lamb wave structural health monitoring systems
Lanza di Scalea, F., & Salamone, S. (2008) · The Journal of the Acoustical Society of America · doi:10.1121/1.2932071 · Cited by 203
Roy, S., Lonkar, K., Janapati, V., & Chang, F.-K. (2014) · Structural Health Monitoring · doi:10.1177/1475921714522846 · Cited by 126
Cited by
Gorgin, R., Luo, Y., & Wu, Z. (2020) · Ultrasonics · doi:10.1016/j.ultras.2020.106114 · Cited by 285
Wu, J., Xu, X., Liu, C., Deng, C., & Shao, X. (2021) · Composite Structures · doi:10.1016/j.compstruct.2021.114590 · Cited by 178
Keshmiry, A., Hassani, S., Mousavi, M., & Dackermann, U. (2023) · Buildings · doi:10.3390/buildings13040918 · Cited by 117
Broer, A. A. R., Benedictus, R., & Zarouchas, D. (2022) · Aerospace · doi:10.3390/aerospace9040183 · Cited by 86
Feng, T., & Aliabadi, M. H. F. (2021) · Materials · doi:10.3390/ma14206148 · Cited by 38
Self-citation
Metadata
- Authors
- Yue, N., & Aliabadi, M. H.
- Venue
- Structural Health Monitoring
- Publisher
- SAGE Publications
- Published
- 2019-11-15
- Volume
- 19
- Issue
- 5
- Pages
- 1487-1506
- ISSN
- 1475-9217 (ISSN-L)
- 1741-3168
- OpenAlex
- W2986990094
- Cited by
- 89
- References
- 2
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A scalable data-driven approach to temperature baseline reconstruction for guided wave structural health monitoring of anisotropic carbon-fibre-reinforced polymer structures. https://app.cochat.ai/papers/10.1177/1475921719887109
- The paper
- Yue, N., & Aliabadi, M. H. (2020). A scalable data-driven approach to temperature baseline reconstruction for guided wave structural health monitoring of anisotropic carbon-fibre-reinforced polymer structures. Structural Health Monitoring. https://doi.org/10.1177/1475921719887109
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.