The DOI matches its Crossref record; its reference list is not available.
Retinal Illumination and Age
Abstract
As our eyes age the amount of light reaching the retina decreases. This is attributable largely to changes in the pupil diameter, to the yellowing of the lens and, to a smaller extent, to a change in the effective path-length of light through the lens. The age variation of retinal illumination is estimated on the basis of published data for standard illuminants A and C, and for three types of fluorescent lamp. In all five cases the small difference found to exist between the light-adapted and dark-adapted eye is greater than differences between the lamps considered. In general, retinal illumination at the age of 60 is about one-third of the value corresponding to an age of 20. The practical significance of the estimate is discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This need increases progressively with age, such that a 60-year old with normal vision needs twice the illumination to see sharply as a 20-year old (Pirkl, 1994; Weale, 1961).”
From Design Principles to Accommodate Older Adults (2012) · cites this paper as Weale, 1961
Citations
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 18 · Cited by 127
Research works printed but not linked: 14
- Stiles W. S., 1933, Proc. Roy. Soc., B, 112, 428
- Richter M., 1956, Die Farbe, 5, 179
- Le Grand Y., 1937, Rev. d'Opt., 16, 201
- Birren J. E., 1950, Geront., 5, 216
- Leinhos R., 1959, Optik, 16, 669
- Weale R. A. ‘Vision Research’. (In Press.)
- Weale R. A., 1960, ‘The Eye and Its Function’
- Smith Priestley, 1883, Trans. OSUK, 3, 79
- Pillat A., 1952, Wien Klin. Wsch'r., 66, 856
- Donders F. C., 1866, ‘Die Anomalien der Refraktion und Accommodation des Auges’
- Chapanis A., 1950, Hum. Biol., 22, 1
- Weale R. A., 1961, Ann. RCS., 28, 16
- Salmony D., 1960, Ann. Rep. Inst. Ophthal., 12, 21
- Ferree C. E., 1934, Trans. Illum. Eng. Soc., 29, 296
Metadata
- Authors
- Weale, R. A.
- Corresponding author
- Weale, R. A.
- Venue
- Transactions of the Illuminating Engineering Society
- Publisher
- SAGE Publications
- Published
- 1961-06
- Volume
- 26
- Issue
- 2_IEStrans
- Pages
- 95-100
- ISSN
- 0096-5952 (ISSN-L)
- OpenAlex
- W2336764049
- Cited by
- 127
- References
- 18
- Citations by year
- 2026: 4 · 2023: 4 · 2022: 1 · 2021: 3 · 2020: 2 · 2019: 3 · 2018: 4 · 2017: 4 · 2016: 3 · 2015: 5 · 2014: 2 · 2013: 2 · 2012: 3
- FWCI
- 1.86
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Transactions of the Illuminating Engineering Society (publishedVersion)
- Topics
- Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Impairment Studies
- Health Sciences › Medicine › Ophthalmology › Ocular and Laser Science Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › Visual perception and processing mechanisms
- Keywords
- retinal illumination, aging, pupil size, lens yellowing, optical path length, light adaptation, dark adaptation, light sources, fluorescent lamps, visual aging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Retinal Illumination and Age. https://app.cochat.ai/papers/10.1177/147715356102600204
- The paper
- Weale, R. A. (1961). Retinal Illumination and Age. Transactions of the Illuminating Engineering Society. https://doi.org/10.1177/147715356102600204
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.