CoChat

Multivendor Continuous Glucose Monitor Integration into the Electronic Health Record: Real-World Experience of an Academic Pediatric Endocrinology Clinic

Open access
Knopp, Michelle I., Leonard, Rachel, Geers, Wayne, Tellez, Siobhan, Vidonish, Bill, Muthuvel, Gajanthan, Magella, Bliss, Yayah Jones, Nana-Hawa, Espinoza, Juan, Corathers, Sarah D. · 2026 · Diabetes Technology & Therapeutics

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index; none of the 28 sources its claims cite is checked for support yet.

Abstract

Background: The rapid advancement of diabetes technology, including continuous glucose monitors (CGMs), insulin pumps, and automated insulin delivery systems, has revolutionized diabetes management. However, current care delivery paradigms have not kept pace, prolonging suboptimal health outcomes for youth with type 1 diabetes (T1D). A significant obstacle is the siloed nature of clinical data. This article explores integrating CGM data for multiple vendors into electronic health records (EHRs) to unify diabetes data in health care practices. Methods: This article describes the integration of diabetes device data, following Integration of Continuous Glucose Monitoring Data into the Electronic Health Record (iCoDE) specifications, in the EHR at an urban, tertiary, academic pediatric medical center serving approximately 500,000 pediatric lives in Southwest Ohio. The Diabetes Center provides specialized interdisciplinary care for about 2200 patients with diabetes, with an average of 200+ new onset cases/year. This project is part of the Cincinnati Children’s Diabetes Clinic Initiative (ConnecT1D), funded by the Helmsley Charitable Trust, aiming to reorient diabetes care from quarterly visits to continuous, proactive care. Results: By evaluating 6 key factors for integration (data sources types, clinical workflows, level of integration, visualizations, sustainable account management, and optimization), we successfully achieved structural interoperability of CGM device data for 3 vendor platforms into the results section of the EHR using HL7 v2.x. Discussion: We present practical tips to optimize the integration experience: identify the problem, mobilize resources, negotiate contracts early, evaluate and optimize the workflow, celebrate early wins, prepare for (inevitable) stumbling blocks, keep asking questions, implement change management techniques, and evaluate integration acceptance, iterate, and monitor. Conclusion: While beneficial for patients and clinical workflows, integration of vendor CGM data into the EHR currently requires significant resources. Challenges remain in optimizing workflows, mapping data, and vendor variability. Ongoing monitoring, maintenance, and optimization are necessary as technology and workflows evolve.

Overview

CoChat Summary

TL;DR

This paper describes a pragmatic, single-center implementation of multivendor CGM data integration into an academic pediatric endocrinology clinic’s Epic EHR, following iCoDE standards. It reports successful structural interoperability with local semantic harmonization for 10 standardized CGM metrics across three vendor platforms, along with workflow, account-management, and optimization lessons.

Key findings

  • Achieved structural interoperability with local semantic harmonization of CGM data from three vendor platforms; 10 standardized metrics based on 2019 Consensus are displayed as discrete rows in the EHR’s Results Review with a link to a PDF AGP.
  • Implemented embedded links, PDF ingestion, and structured data integration; standardized on a 14-day interval; one vendor’s customizable PDF was reduced by approximately 50%; after optimization, average 170 data orders per month.
  • Account management required manual review of 3109 accounts: 1080 duplicates or not seen in >2 years were deleted, 753 never-activated accounts were manually deleted, and ongoing review identifies 10 duplicate accounts per quarter; manual deletion takes about 1 h per 50 accounts.
  • Families reported liking CGM results in patient portals alongside other diabetes laboratory data; clinicians reported streamlined workflow, reduced check-in times, and reduced printed reports; average time to signed vendor contract was 10 months.

Methods

  • Design: pragmatic implementation/quality improvement project describing process, decisions, and learnings for integrating multivendor CGM data into an academic pediatric Diabetes Center’s EHR, based on the iCoDE Standard Project.
  • Data/sample: local Epic EHR; multiple vendor source systems explored (Abbott, Dreamed, Glooko, Tidepool), with integration achieved for three vendor platforms; 3109 patient/vendor accounts reviewed for linkage.
  • Main analysis: descriptive process evaluation using project timeline, stakeholder/team documentation, utilization metrics (e.g., data orders per month), account-review counts, and qualitative feedback from clinicians and patient/family advisory board.

Limitations

  • Stated: integration remains dynamic and ongoing, with pragmatic challenges including mapping efforts, vendor variability, limited technical expertise, and ongoing maintenance that limit widespread adoption; raw CGM data were not incorporated, and only one vendor supported direct embedded-authentication navigation.
  • Stated: the EHR vendor had no initial recommendations for ideal visualization/storage; clinician-facing visualizations (e.g., Synopsis) were outside scope and not completed; Results Review required approval from the laboratory medical director due to CAP regulations.
  • Evident from text: this is a single-center academic pediatric experience with descriptive utilization and qualitative feedback, without a control group or formal clinical outcome evaluation; contract delays and pediatric account-matching issues may limit generalizability.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1177/15209156251395034

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 0 Not valid · 24 Not checked · 73 Own results and interpretations

43 more claims

Create a free account to see all 97 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 37
  • It may state two separate claims as one. 20

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Research works printed but not linked: 2

  1. technology in youth with type 1 diabetes. 10.1089/dia.2020.0618Diabetes Technol Ther. 2372021 · doi:10.1089/dia.2020.0618diabetes
  2. C Juan, Dck Espinoza, A P Vidmar, The 2022 iCoDE Report: CGM-EHR Integration Standards and Recommendations. 2022

Cited by

See all 4

Metadata

Authors
Knopp, M. I., Leonard, R., Geers, W., Tellez, S., Vidonish, B., Muthuvel, G., Magella, B., Yayah Jones, N.-H., Espinoza, J., & Corathers, S. D.
Affiliations
  • Cincinnati Children's Hospital Medical Center (US)
  • Department of Pediatrics, University of Cincinnati, Cincinnati, Ohio, USA.
  • Lurie Children's Hospital (US)
Corresponding author
Knopp, Michelle I.
Venue
Diabetes Technology & Therapeutics
Published
2025-11-19
Volume
28
Issue
5
Pages
472-482
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W4416387089
Cited by
4
References
28
Citations by year
2026: 3 · 2025: 1
FWCI
3.12
Type
journal article
Language
en
Open access
Licence
Locations
  • Diabetes Technology & Therapeutics (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
Keywords
continuous glucose monitoring, electronic health record integration, type 1 diabetes, pediatric diabetes care, interoperability, clinical workflow optimization, diabetes technology, data mapping, change management
MeSH terms
Academic Medical Centers, Adolescent, Blood Glucose, Child, Diabetes Mellitus, Type 1, Female, Humans, Insulin Infusion Systems, Male, Ohio, Blood Glucose Self-Monitoring, Electronic Health Records

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.