Impact of Curing Protocol on Conversion and Shrinkage Stress
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Since considerable shrinkage stress develops during the curing of dental composites, various soft-start photocuring protocols, aiming to lower stress but not compromise conversion, have been proposed. We hypothesized that utilizing soft-start photocuring will result in not only reduced stress, but also decreased conversion. We evaluated the impact of 3 protocols (soft-start, pulse, and standard) on the stress development and polymerization extent of an experimental composite. A novel set-up capable of simultaneous shrinkage stress, conversion, and temperature measurements on the same specimen was utilized. Analysis of the data shows that stress rises dramatically as a function of conversion in the vitrified state, and the utilization of soft-start or pulse curing results in specimens with reduced final conversion and shrinkage stress, compared with specimens cured according to the standard full-intensity protocol. Finally, this study demonstrates that the predominant reason for the reduced shrinkage stress attained with soft-start or pulse curing is a modest decrease in final conversion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Odian, G. (2004) · doi:10.1002/047147875x · Cited by 7,158
Polymerization shrinkage and polymerization shrinkage stress in polymer-based restoratives
Davidson, C. L., & Feilzer, A. J. (1997) · Journal of Dentistry · doi:10.1016/s0300-5712(96)00063-2 · Cited by 729 · cited 1×
“However, constrained shrinkage during polymerization densification generates polymerization shrinkage stress, which is one of the most significant concerns during the highly technique-sensitive clinical placement of composite restorations (Carvalho et al., 1996; Davidson and Feilzer, 1997).”
BackgroundA New Derivation of Average Molecular Weights of Nonlinear Polymers
Macosko, C. W., & Miller, D. R. (1976) · Macromolecules · doi:10.1021/ma60050a003 · Cited by 691 · cited 1×
“During photopolymerization of multi(meth)acrylate systems, the development of a crosslinked network is rapid, and gel point conversion is well below 10% (Macosko and Miller, 1976; Odian, 1991).”
BackgroundPhotoinitiated crosslinking polymerisation
Decker, C. (1996) · Progress in Polymer Science · doi:10.1016/0079-6700(95)00027-5 · Cited by 686 · cited 2×
“During free-radical photopolymerization of dimethacrylate dental resins, the rapid development of a highly crosslinked network drastically restricts the mobility of reacting species, and instigates such phenomena as auto-acceleration, reactiondiffusion-controlled termination, and incomplete conversion (Bowman and Anse…”
BackgroundDetermination of double bond conversion in dental resins by near infrared spectroscopy
Stansbury, J. W., & Dickens, S. H. (2001) · Dental Materials · doi:10.1016/s0109-5641(00)00062-2 · Cited by 524 · cited 3×
“For dental resins cured under clinical conditions, final conversion is typically between ca. 55 and 75% (Ferracane, 1995; Stansbury and Dickens, 2001b ), which also agrees with the ultimate conversions observed in this study.”
BackgroundResultSelf-citationNetwork formation by chain crosslinking photopolymerization and its applications in electronics
Kloosterboer, J. G. (2005) · Advances in Polymer Science · doi:10.1007/bfb0025902 · Cited by 492 · cited 1×
“One particularly important phenomenon is excess free volume ( Kloosterboer, 1988; Anseth et al., 1995a).”
BackgroundA review of polymerization contraction: the influence of stress development versus stress relief.
Carvalho, R. M., Pereira, J. C., Yoshiyama, M., & Pashley, D. H. (1996) · PubMed · Cited by 487
Current Trends in Dental Composites
Ferracane, J. L. (1995) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/10454411950060040301 · Cited by 437 · cited 2×
“55 and 75% (Ferracane, 1995; Stansbury and Dickens, 2001b), which also agrees with the ultimate conversions observed in this study.”
ResultLovelh, L. G., Newman, S. M., & Bowman, C. N. (1999) · Journal of Dental Research · doi:10.1177/00220345990780081301 · Cited by 341 · cited 1×
“Other researchers have also observed that systems cured with higher incident light intensity achieve higher polymerization rates and final conversion (Maffezzoli and Terzi, 1998; Lovell et al., 1999).”
BackgroundSelf-citationFeilzer, A. J., Dooren, L. H., de Gee, A. J., & Davidson, C. L. (1995) · European Journal of Oral Sciences · doi:10.1111/j.1600-0722.1995.tb00033.x · Cited by 316 · cited 2×
“It has been claimed that the soft-start curing method partially relieves shrinkage stress, and achieves improved integrity of the composite/tooth interface, without compromising the final double-bond conversion or mechanical properties of the cured dental composite (Uno and Asmussen, 1991; Feilzer et al., 1995; Mehl e…”
Background
Cited by
Progress in dimethacrylate-based dental composite technology and curing efficiency
Leprince, J. G., Palin, W. M., Hadis, M. A., Devaux, J., & Leloup, G. (2013) · Dental Materials · doi:10.1016/j.dental.2012.11.005 · Cited by 534
Cheng, L., Weir, M. D., Xu, H. H. K., Antonucci, J. M., Kraigsley, A. M., Lin, N. J., Lin-Gibson, S., & Zhou, X. (2012) · Dental Materials · doi:10.1016/j.dental.2012.01.005 · Cited by 354
“Dental composites are increasingly used due to their excellent esthetics and improved performance [5–11].”
Nanocomposite containing amorphous calcium phosphate nanoparticles for caries inhibition
Xu, H. H. K., Moreau, J. L., Sun, L., & Chow, L. C. (2011) · Dental Materials · doi:10.1016/j.dental.2011.03.016 · Cited by 309
Toward an enhanced understanding and implementation of photopolymerization reactions
Bowman, C. N., & Kloxin, C. J. (2008) · AIChE Journal · doi:10.1002/aic.11678 · Cited by 280
Self-citationLight curing strategies for lithography-based additive manufacturing of customized ceramics
Mitteramskogler, G., Gmeiner, R., Felzmann, R., Gruber, S., Hofstetter, C., Stampfl, J., Ebert, J., Wachter, W., & Laubersheimer, J. (2014) · Additive Manufacturing · doi:10.1016/j.addma.2014.08.003 · Cited by 263
Novel dental adhesives containing nanoparticles of silver and amorphous calcium phosphate
Melo, M. A. S., Cheng, L., Zhang, K., Weir, M. D., Rodrigues, L. K. A., & Xu, H. H. K. (2013) · Dental Materials · doi:10.1016/j.dental.2012.10.005 · Cited by 259
Kim, D., Shim, J.-S., Lee, D., Shin, S.-H., Nam, N.-E., Park, K.-H., Shim, J.-S., & Kim, J.-E. (2020) · Polymers · doi:10.3390/polym12112762 · Cited by 253
Shrinkage Stresses Generated during Resin-Composite Applications: A Review
Schneider, L. F. J., Cavalcante, L. M., & Silikas, N. (2010) · Journal of Dental Biomechanics · doi:10.4061/2010/131630 · Cited by 226
“(ii) Concurrent experiments on degree of C=C conversion (DC) and stress development show that soft-start irradiation procedures give somewhat lower DC levels, associated with reduced stress [114];.”
BackgroundGenerating thickness gradients of thin polymer films via flow coating
Stafford, C. M., Roskov, K. E., Epps, T. H., & Fasolka, M. J. (2006) · Review of Scientific Instruments · doi:10.1063/1.2173072 · Cited by 188
Zhang, K., Melo, M. A. S., Cheng, L., Weir, M. D., Bai, Y., & Xu, H. H. K. (2012) · Dental Materials · doi:10.1016/j.dental.2012.04.027 · Cited by 181
Chen, C., Weir, M. D., Cheng, L., Lin, N. J., Lin-Gibson, S., Chow, L. C., Zhou, X., & Xu, H. H. K. (2014) · Dental Materials · doi:10.1016/j.dental.2014.05.025 · Cited by 129
“Advances in polymers and fillers have significantly enhanced the composite properties and clinical performance [5–11].”
BackgroundCheng, L., Zhang, K., Zhou, C.-C., Weir, M. D., Zhou, X.-D., & Xu, H. H. K. (2016) · International Journal of Oral Science · doi:10.1038/ijos.2016.13 · Cited by 99
Thiol-ene-methacrylate composites as dental restorative materials
Boulden, J. E., Cramer, N. B., Schreck, K. M., Couch, C. L., Bracho-Troconis, C., Stansbury, J. W., & Bowman, C. N. (2011) · Dental Materials · doi:10.1016/j.dental.2010.11.001 · Cited by 93
Self-citationDental plaque microcosm biofilm behavior on calcium phosphate nanocomposite with quaternary ammonium
Cheng, L., Weir, M. D., Zhang, K., Wu, E. J., Xu, S. M., Zhou, X., & Xu, H. H. K. (2012) · Dental Materials · doi:10.1016/j.dental.2012.04.024 · Cited by 82
“[16] Lu H, Stansbury JW, Bowman CN.”
Metadata
- Authors
- Lu, H., Stansbury, J. W., & Bowman, C. N.
- Venue
- Journal of Dental Research
- Publisher
- SAGE Publications
- Published
- 2005-09
- Volume
- 84
- Issue
- 9
- Pages
- 822-826
- ISSN
- 0022-0345 (ISSN-L)
- 1544-0591
- OpenAlex
- W2068391276
- Cited by
- 191
- References
- 18
- FWCI
- 11.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.