Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Obstructive Sleep apnea Therapy

Hoekema, A., Stegenga, B., Wijkstra, P.J., van der Hoeven, J.H., Meinesz, A.F., de Bont, L.G.M. · 2008 · Journal of Dental Research

Abstract

In clinical practice, oral appliances are used primarily for obstructive sleep apnea patients who do not respond to continuous positive airway pressure (CPAP) therapy. We hypothesized that an oral appliance is not inferior to CPAP in treating obstructive sleep apnea effectively. We randomly assigned 103 individuals to oral-appliance or CPAP therapy. Polysomnography after 8–12 weeks indicated that treatment was effective for 39 of 51 persons using the oral appliance (76.5%) and for 43 of 52 persons using CPAP (82.7%). For the difference in effectiveness, a 95% two-sided confidence interval was calculated. Non-inferiority of oral-appliance therapy was considered to be established when the lower boundary of this interval exceeded −25%. The lower boundary of the confidence interval was −21.7%, indicating that oral-appliance therapy was not inferior to CPAP for effective treatment of obstructive sleep apnea. However, subgroup analysis revealed that oral-appliance therapy was less effective in individuals with severe disease (apnea-hypopnea index > 30). Since these people could be at particular cardiovascular risk, primary oral-appliance therapy appears to be supported only for those with non-severe apnea.

Overview

Integrity signals

Registry

Crossref · 10.1177/154405910808700917

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 26 references

Research works printed but not linked: 1

  1. Altman DG -1991- Designing research. In: Practical statistics for medical research. Altman DG, editor. London, England: Chapman & Hall, pp. 74–106.

Cited by

See all 190

Metadata

Authors
Hoekema, A., Stegenga, B., Wijkstra, P. J., van der Hoeven, J. H., Meinesz, A. F., & de Bont, L. G. M.
Affiliations
  • University Medical Center Groningen (NL)
  • Department of Oral and Maxillofacial Surgery,
Venue
Journal of Dental Research
Published
2008-09
Volume
87
Issue
9
Pages
882-887
ISSN
  • 0022-0345 (ISSN-L)
  • 1544-0591
OpenAlex
W2065160870
Cited by
186
References
26
Citations by year
2026: 1 · 2025: 2 · 2024: 2 · 2023: 3 · 2022: 11 · 2021: 11 · 2020: 7 · 2019: 10 · 2018: 8 · 2017: 18 · 2016: 18 · 2015: 27 · 2014: 26 · 2013: 11 · 2012: 8
FWCI
5.16
Type
journal article
Language
en
Open access
closed
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Journal of Dental Research (publishedVersion)
  • PubMed (publishedVersion)
  • University of Groningen research database (University of Groningen / Centre for Information Technology) (submittedVersion)
Funders
Universitair Medisch Centrum Groningen
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Dentistry › Oral Surgery › Temporomandibular Joint Disorders
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
Keywords
obstructive sleep apnea, oral appliances, continuous positive airway pressure, non-inferiority, treatment effectiveness, apnea-hypopnea index, severe sleep apnea, cardiovascular risk
MeSH terms
Adult, Humans, Middle Aged, Orthodontic Appliances, Removable, Severity of Illness Index, Treatment Outcome, Patient Satisfaction, Occlusal Splints, Polysomnography, Mandibular Advancement, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Obstructive Sleep apnea Therapy. https://app.cochat.ai/papers/10.1177/154405910808700917
The paper
Hoekema, A., Stegenga, B., Wijkstra, P. J., van der Hoeven, J. H., Meinesz, A. F., & de Bont, L. G. M. (2008). Obstructive Sleep apnea Therapy. Journal of Dental Research. https://doi.org/10.1177/154405910808700917

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.