The DOI matches its Crossref record.
Measuring Arm and Hand Joint Kinematics to Estimate Impairment During a Functional Reach and Grasp Task after Stroke
Abstract
Background: Current approaches to characterizing deficits in upper limb movements after stroke typically focus either on changes in a functional measure, for example, how well a patient can complete a task, or changes in impairment, for example, isolated measurements of joint range of motion. However, there can be notable dissociations between static measures of impairment versus those of function. Objective: We develop a method to measure upper limb joint angles during performance of a functional task and use measurements to characterize joint impairment in the context of a functional task. Methods: We developed a sensorized glove that can precisely measure select finger, hand, and arm joints while participants complete a functional reach-to-grasp task involving manipulation of a sensorized object. Results: We first characterized the accuracy and precision of the glove’s joint angle measurements. We then measured joint angles in neurologically intact participants (n = 4 participants, 8 limbs) to define the expected distribution of joint angle variation during task execution. These distributions were used to normalize finger, hand, and arm joint angles in stroke participants (n = 6) as they performed the task. We present a participant-specific visualization of functional joint angle variance which illustrated that stroke participants with nearly identical clinical scores exhibited unique patterns of joint angle variation. Conclusions: Overall, measuring individual joint angles in the context of a functional task may inform whether changes in functional scores over recovery or rehabilitation are driven by changes in impairment or the development of compensatory strategies, and provide a quantified path toward personalized rehabilitative therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While many hand-tracking technologies have been developed, most are in the form of a glove that can be difficult for people with movement impairments to don/doff and impedes sensation [9,10,11,12,13]”
From A Low-Cost, Accurate, and Easily-Worn E-Skin and IMU Hand Kinematic Measurement System (2026) · cites this paper as [11]
In the citing paper
“These on-hand error levels are comparable with those reported by studies with sensors mounted on a wearable glove (Khanna, Oppenheim et al. [11] used electromagnetic sensors and reported a mean root mean square (RMS) error of 6.91 degrees, and Park et al. [9] used liquid metal strain sensors and reported a mean error of 4.61 degrees in calibrated and ~10.5 degrees in non-calibrated applications).”
From A Low-Cost, Accurate, and Easily-Worn E-Skin and IMU Hand Kinematic Measurement System (2026) · cites this paper as [11]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 19
- 10.1177/15459683211062890 · DOI
- 10.1177/1545968312452631 · DOI
- 10.1177/1545968317697034 · DOI
- 10.1177/1747493019873519 · DOI · Paper page
- 10.1038/s41593-018-0209-y · DOI · Paper page
- 10.1088/1741-2560/9/2/026025 · DOI
- 10.1177/1545968306289299 · DOI
- 10.1682/jrrd.2010.02.0013 · DOI
- 10.1109/JSEN.2017.2776262 · DOI
- 10.3389/frvir.2021.663618 · DOI
- 10.1152/jn.00936.2009 · DOI
- 10.1152/jn.00447.2021 · DOI
- 10.2522/ptj.20100341 · DOI
- 10.1093/brain/awh116 · DOI · Paper page
- 10.1109/TNSRE.2022.3226067 · DOI
- 10.3389/fneur.2019.00240 · DOI
- 10.1097/NPT.0000000000000350 · DOI
- 10.1016/j.cell.2021.01.023 · DOI
- 10.1016/j.neuron.2022.06.024 · DOI
Cited by
A Low-Cost, Accurate, and Easily-Worn E-Skin and IMU Hand Kinematic Measurement System
Oppenheim, T., Schlegel, H., Xie, P. Y., Khokhar, Z., & Khanna, P. (2026) · Sensors · doi:10.3390/s26154795
Self-citation
Metadata
- Authors
- Khanna, P., Oppenheim, T., Tu-Chan, A., Abrams, G., & Ganguly, K.
- Affiliations
- Department of Neurology, University of California, San Francisco, CA, USA
- Department of Mechanical Engineering, California Maritime Academy, Vallejo, CA, USA
- Venue
- Neurorehabilitation and Neural Repair
- Publisher
- SAGE Publications
- Published
- 2023-06
- Volume
- 37
- Issue
- 6
- Pages
- 409-417
- ISSN
- 1545-9683
- 1552-6844
- Cited by
- 7
- References
- 0
- Language
- en
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Funders
- NIMH (R01MH111871)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measuring Arm and Hand Joint Kinematics to Estimate Impairment During a Functional Reach and Grasp Task after Stroke. https://app.cochat.ai/papers/10.1177/15459683231179173
- The paper
- Khanna, P., Oppenheim, T., Tu-Chan, A., Abrams, G., & Ganguly, K. (2023). Measuring Arm and Hand Joint Kinematics to Estimate Impairment During a Functional Reach and Grasp Task after Stroke. Neurorehabilitation and Neural Repair. https://doi.org/10.1177/15459683231179173
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.